Loading...
HomeMy WebLinkAboutCertificate of Occupancy 'CITY HALL 215 Church Avenue P. O. Box 1130 Oshkosh, Wisconsin 54902 -1130 City of Oshkosh (ED Q/} -NC�IH May 31, 1995 Mokler Properties, Inc. 1117 W. New York Avenue Oshkosh, WI 54901 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby granted for the new storage building addition located at 417/419 E. Nevada Avenue, Oshkosh, WI 54901 as described in Building Permit Application number(s) 40475. This building is to be used only as a storage warehouse and is located in the M -3 Heavy Industrial District. NOTE: A new Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. BUILDING INSPECTOR OWIIER ADDRESS -5 719-9 F /rAv DATE `7/ /`i PERMIT #'tt i 7s USE Sir .v ems•- 47 Work consists of V L IZ ih c, GENERAL CONTRACTOR MASON CONTRACTOR ZONE Width of lot DATE INSPECTIONS A REMARKS .0/9's.": Ye k 0 V-- /9 E V n G 0 V w A 0 r y m A v NAILING ADDRESS Front of lot b u/. l SAFETY BUILDINGS DIVISION 1) 1 �V 8 State of Wisconsin Department of Industry, Labor and Human Relations May 20, 1994 1053A East Green Bay Street rz Shawano WI 54166 MA`! 25 1994 CLARKE ASSOCIATES MOKLER PROPERTIES STEVEN D CLARKE i i t. 41 i ,:w,,; CHRIS MOKLER 1347 CEAPE AVENUE 1117 W NEW YORK OSHKOSH WI 54901 OSHKOSH WI 54901 RE: STORAGE GARAGE MOKLER PROPERTIES 415 417 E HEVADA OSHKOSH County of WINNEBAGO Plan Number 94 -05- 1005 -B Area: 4,992 square feet Suprv. Professional, Building: STEVEN D CLARKE Your Building addition plans have been withheld. Plan approval for the referenced project is WITHHELD pending receipt of additional information and /or revised plans. If the additional information and /or plans are not received within two months of the date on this letter, the plans will be stamped "Not Approved" and returned. When revised plans are required to satisfy the following violations, at least four bound sets of the revised plans shall be submitted for review. If the total building volume exceeds 50,000 cubic feet, the revised plans are required to bear the original signature and seal. Approval is withheld because of the following code violations: So as to expedite the rereview of the additional information /revised plans required by this letter, it is recommended that you call this office as soon as possible to schedule the rereview. ILHR 62.995(3) Mini storage buildings shall be divided into areas not greate3r than 3,000 square feet by 2 -hour fire- resistive walls extending from the non combustible floor to the underside of the roof deck. SBD -6423( R. 01/91) SAFETY BUILDINGS DIVISION 'Z.'1, State of Wisconsin Department of Industry, Labor and Human Relations CLARKE ASSOCIATES May 20, 1994 Page 2 Please provide information about the existing building (Class of construction, Occupancy use,...). This building is classified ,as No. 8, wood frame construction. Sincerel y,, Moktar Taamallah Plan Examiner (715) 524 -3626 MBT:vs:1302 cc: State Building Inspector: R -3 Ochs (414) 929 -3167 Fridays Building Inspector, OSHKOSH SHD 6423IR.01/811 SAFETY BUILDINGS DIVISION -1 State of Wisconsin Department of Industry, Labor and Human Relations R 14"i 1,7 May 27, 1994 1053A East Green Bay Street Shawano WI 54166 2. 3 1_;- CLARKE ASSOCIATES MOKLER PROPERTIES STEVEN D CLARKE CHRIS MOKLER 1347 CEAPE AVENUE 1117 W NEW YORK OSHKOSH WI 54901 OSHKOSH WI 54901 RE: STORAGE GARAGE MOKLER PROPERTIES 415 417 E HEVADA OSHKOSH County of WINNEBAGO Plan Number 94- 05- 1005 -LB Area: 4,992 square feet Suprv. Professional, Building: STEVEN D CLARKE Your revised Building addition plans have been conditionally approved. The above referenced plans have been stamped CONDITIONALLY APPROVED based upon review for conformance to the current edition of the Wisconsin Administrative Building and Heating, Ventilating and Air Conditioning Code, chapters ILHR 50 -64. These plans have NOT been reviewed for conformance to the Plumbing Code (chs. ILHR 81 -86), the Electrical Code (ch. ILHR 16) and any ILHR code not specifically mentioned. Subject to local regulations, construction may proceed except for those conditions listed below. The necessary corrections must be made before construction begins. The owner, as defined in chapter. 101.01 (2)(e), Wisconsin Statutes, is responsible for compliance with all code requirements. The owner shall notify the state building inspector and local officials before taking possession of the building. The building will be inspected during and after construction. ILHR 50.15 EVIDENCE OF APPROVAL. The architect, professional engineer, designer, builder or owner shall keep one set of plans bearing the appropriate stamp of approval at the building site. All future plan submittals required to complete this project must be submitted SHD -64231 R. 01/91) 4 .11 SAFETY BUILDINGS DIVISION State of Wisconsin Department of Industry, Labor and Human Relations CLARKE ASSOCIATES May 27, 1994 Page 2 in quadruplicate, and be accompanied by the Plans Approval Application form (SB -118) and fees. When the building volume exceeds 50,000 cubic feet; all application forms shall include the name of the building or component`` designer AND BE. SIGNED BY THE SUPERVISING PROFESSIONAL OF THE PROJECT. Prior to installation, one copy of the wood truss plans and calculations shall be submitted to this office and one copy provided at the job site. When the total building volume exceeds 50,000 cubic feet, each set of plans shall bear an indication of review which has been signed or initialled by the building designer of record. This building is classified as No. 8, wood frame construction. Sincerely, Moktar Taamailah:. Plan Examiner (715) 524 -3626 MBT:vs:1238 cc: State Building Inspector: R -3 Ochs (414) 929 -3167 Fridays Building Inspector, OSHKOSH- a, t SHD -6423 IR. 61/911