HomeMy WebLinkAbout0100209-Electric e OSHKOSH ON THE WATER CITY OF OSHKOSH No 100209 ELECTRIC PERMIT - APPLICATION AND RECORD Job Address 3550 MOSER ST Owner BANNER PACKAGING INC Create Date 03/14/2003 Contractor ARROW ELECTRIC OF OSHKOSH Category 653 - Industrial-Addition/Remodels Plan Service 10 New 480/277 0 Change 0 Temp Volts Circuits Type 0 10 Overhead 0 Underground Fixtures 18 Amps 200 Switches 0 Receptacles Appliances Use/Nature of Factory/ Wiring for the warehouse addition (Cold Storage). Work Fees: Valuation $10,000.00 Plan Approval $0.00 Permit Fee Paid $180.00 Issued By: Date 03/14/2003 U Permit Voided I In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner Address POBOX 3960 - 280 E FERNAU AVE OSHKOSH WI 54903 - 3960 -- Telephone Number (920) 426-4252 v City of Oshkosh Division of Inspection Services P.O. Box 1130 Oshkosh, WI 54903-1130 Phone (920) 236-5050 Fax (920) 236-5084 REC E lYE D MAR 1 0 2003 ELECTRICAL PERMI-P~mM1U)N All information after bolœfli:l~Þr¥tJÐ[yaQP<MENT Incomplete applications will not be processed. ~ OfHKOfH ON THE WATER . Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903-1128. Commencing work without permìt(s) will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR If vou are a contractor varticžvatinf! in the Permit Fee Account Svstem and have adequate funds. check here if VOli want this vrocessed throllf!h your account 0 DATE JOB ADDRESS '3 ::.)56 m ó5e /t!' ð Sh¿5 Þ-¡ OWNER_ßr:)n 1"'1 el!: jJ,qL/t!!:A!:,'J/;" CONTRACTOR /9-¿L¿;J4/ £¿eC-f-~/~ CHECK 0 ALL APPLICABLE USE CATEGORY . . . DSingle Family DDuplex . DMulti-Famil)' DRental 0 Commercial SERVICE DNew DChange DTemporary DNot Applicable TYPE DOverhead DUnderground FILL IN THE APPROPRIATE BLANK WITH THE NUMBER Voltsj/¡¡ô / ó?77 Phase .3 Amps ~i') / Receptacles # Circuits # Switches # Fixtures # CHECK 0 ALL APPLICABLE DRange DFan OR Blower DMotors DDishwasher DFurnace DGas Pumps DGarbage Disposal DAIC 0 Other DDryer DWaterHeater DElectric Sign DESCRIPTION OF ALL WORK BEING DONE sr- 7.- ð3 J;?Industrial DNot Applicable /<f' VALUE (Including labor and all materials including light fixtures) $ ".-a /CJ/ ðcJð MASTER ELECTRICIAN /?/A"e :5~ ~t!'A!:.s; 3/02 fÎiIIt.. j commerce.wí.gov ~ i!~g n~jJ:! LOF7 >, , ~" Safety and Buildings t41 NW BARSTOW ST FL 4TH WAUKESHA WI 53188-3789 TOO #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke. Secretary July 18. 2005 JUL 2 5 2005 CUST ID No. 993852 Fee Required $ Fee Received $ Balance Due $ 250.00 250.00 0.00 JIM MARTIN WISCONSIN PUBLIC SERVICE CORP 3300 N MAIN ST OSHKOSH WI 54901 WfSMART code: 7631 REQUEST FOR ADDITIONAL INFORMATION SITE: Banner Packaging 3550 Moser St City of Oshkosh, 54901 ; Fire Dept ID: 7003 FOR: No Objects for this Transaction Identification Numbers Transaction ill No. 1140370 Site ill No. 584936 Please refer to both identification numbers. above, in all corresnondence with the agency. The submittal described above has been placed on HOLD and the review and approval is pending subject to receipt of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional information and/or revised plans. the plans will be reviewed for compliance to applicable Wisconsin Administrative Codes and Wisconsin Statutes. The following must be corrected/revised and accompany the resubmittal: My understanding is that you have applied for a petition for variance in order to resolve a conflict with the City of Oshkosh. According to City officials, the work done by WPS at Banner Packaging was done without a City of Oshkosh electrical!icense, permit and the cables were buried without inspection by the local electrical inspector. My understanding is customer owns the c.onductors and distribution equipment. For this reason the installation is covered by the Scope of Comm 16 and should have been installed to meet the requirements of Comm 16 and the 2002 edition of the National Electric Code. A petition on the type of cable used is only appropriate if you can establish an equivalency between the cable used for the installation at Banner Packaging and the type of cable required by the Code. The National Electric Code requires the use of Type MV cable for this type of installation. Type MV cahle is covered by Article 328 in the 2002 NEC. You have submitted copies of pages from the WPS cable purchasing specifications. No background information on the cable actually used on the job or comparison with approved cables was included. Please submit a complete comp'arison which includes cable specifications for the actual type of cable used on the project. This type of information is commonly available through the cable manufacturer. Your report shall compare the construction of the type of cable used to the applicable requirements for the manufacture of listed type MV cable. Type MV Cable is listed to UL 1072, Medium Voltage Power Cable. A competent professional engineer should do the comparison. Presumably the comparison will be favorable and will form the basis for establishing an equivalency between the technical requirements of the National Electric Code and the cable you elected to use. The City of Oshkosh has requested our assistance is determining the adequacy of the installation. This request came as part of their response in completing the Municipal Building Inspection Recommendation form. This is a separate issue from the cable insulation issue. You did submit a copy of the WPS cable burial depth specifications. No details were provided on the actual burial depth at Banner Packaging and any type of supplemental protection used. No details were submitted that indicate what type of post-installation testing WPS performed to verify the insulation 'r" JIM MARTIN Page 2 7118/2005 integrity. Please submit a separate report from your construction crew. Please provide details on: 1) the burial depth; 2) the relationship of burial depth to finished grade at the time of installation; 3) supplemental protection for the cables. if any; 4) the type of backfill; 5) the details on the type and methods used to terminate the cables at the terminals of the distribution equipment; 6) and copies of any test reports such as DC High-pot or In-line partial discharge. Other relevant infonnation may be submitted if you think it builds the case for City acceptance of an installation that was not inspected. Send your resubmittal into the address listed above, unless otherwise noted, and the department will review the resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. If you have any questions, after reading the above COmments and related code sections cited. please call me at the telephone number below. If the above requested information and/or plans are not received within 30 business days of the date of this correspondence. this submittal will be returned denied. No fees will be refunded. and a new fee. application form, and submittal of plans/specifications will be required should you desire to continue with this project. The code in effect at the time of new submittal would apply. Sincerely, -;/- I /7 /1f{f)~ J^ (:;?~ Thomas J Gl y. P.E. V Electrical Engineer. Integrated Services (414)852-3696. tgarvey@commerce.state.wi.us