HomeMy WebLinkAbout0097102 BOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type
1270 PHEASANT CREEK DR
110 - New Single Family
CITY OF OSHKOSH
BUILDING PERMIT 'APPLICATION AND RECORD
Create Date
owner RUSCH HOMES
Contractor RUSCH HOMES LLC
Building O Sign O Canopy (~ Fence (~ Raze
No 0097102
08/28/2002
Plan D1-125-0802R
Zoning R-1 Class of Const: 8
Unfinished/Basement 1176 Sq. Ft. Rooms 3
Finished/Living 1176 Sq. Ft. ~ Bedrooms 4
Garage 528 Sq. Ft. Baths 3
Foundation ~I Poured Concrete (~ Floating Slab (~) Pier
O Concrete Block O Post (~) Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units 1
Height 15 Ft.
Stories 1
O Other
Height Permit Not Required
# Structures 1
Size IRR
[] Projection
Canopies
Signs
Use/Nature qSFP,/1 story home with a 2 car attached garage, 14'x14' rear patio, and a 20' wide concrete driveway.
of Work
HvAc Contractor
Electric Contractor
Fees: Valuation
Issued By: ¢
CONDON TOTAL COMFORT
CUMINGS ELECTRIC
Plan Approval
Plumbing Contractor HANSON QUALITY PLUMBING
$75.00 Permit Fee Paid
[] Permit Voided
$320.00 Park Dedication $100.00
Date 09/06/2002 Final/O.P. 00/00/0000
In the performance of this work I ¢'gree~perform all work pursuant to rules governing the described construction.
Signature ~ ~ Date
Agent/Owner
Address P O BOX 423 Omro WI 54963 - 0000 Telephone Number
685-0241OR mobile
OSHKOSH
ON THE WATER
GRADE STAKE FORM.
Name RUSCH HOMES Address
Lot 44 Block
Subdivision lstAdd to Pheasant Creek Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 08/28/2002 Set By
1270 PHEASANT CREEK DR
Grade Stake Number 6806
Create Date 08/28/2002
D.W.G. BK- 573, P- 57
Ward
bi. Sidewalk Existing J
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade_established before excavation
has commenced.
Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
Owner's Name
RUSCH HOMES
Contractor: L~J Con~] Elec'~
RUSCH HOMES LLC
Contractor:
CUMINGS ELECTRIC
Contractor:
CONDON TOTAL COMFORT
Contractor: L_J Con
HANSON QUALITY PLUMBING
Lot Area
Building Address
1270 PHEASANT CREEK DR
District(s) Permit No.
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
[] Constr [] HVAC [] Elec [] Plbg
Application No.
0097102
ParCe No.
[] Erosion [] Other:
Mailing Address
P O BOX 423
Lic,/Cert # Mailing Address
879882 P O BOX 423
OMRO WI 54963- 0000
Omro WI 54963- 0
Mailing Address
PO BOX 749 1414 COUNTY RD JJ NEENAH
WI 54957 -749
Mailing Address
11 BLACKBURN ST RIPON
Wl54971 -184
Mailing Address
BLUEMOUND RD
APPLETON WI 54914 -0
Telephone No.
685-0241
Telephone No.
685-0241ORm(
Telephone No.
231-5946
Telephone No.
(920)748-5050
Telephone No.
730-0205
1/4, 1/4,Section ,T N,R E(or)W
Subdivision Name
1st Add to Pheasant Creek
JLot No.
44
Block No.
Front Rear Left Right
New [] Repair Single Family Entrance Panel Forced Air Furnace
Fuel
[] Alteration [] Raze Two Family Size: 200 am [] Radiant Baseboard or Panel
Garage Service: [] Heat Pump Space Htg
[] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg
[] Other: [] Underground [] Central Air Conditioning Dwelling unit will have 3 kilowatt or
[] Site Constructed Concrete Other more installed electric space heating equil
Infiltration control option is: [] Full sealing
Unfinished [] Manufactured Masonry
Treated Wood Sewer of joints. [] Blower door test. [] Exterior
Basement 1176 Sq. ft. [] Municipal ~ir infiltration barder.
Living Area 1176 Sq. ff. 1-Story Other [] Septic
[] 2-Story Permit No. Envelope 22451 BTU/HR
Garage 526 Sq. ft. [] Other [] Seasonal Infiltration 14394 BTU/HR
[] Permanent [] Municipal Utility
[] Plus Basement [] Other [] Private On-Site Well $130,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express ~_~l;~d,~o~Department or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE /Z..~ DATE SIGNED
This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS
revocation of this permit or other penalty
see standard conditions of approval
NOTE: ALL HABITABLE ROOMS ARE REQUIRED TO BE PROVIDED WITH 8% LIGHT AND 3.5% VENTILATION
[] Town [] Village [] City [] County L_J State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name Nicole Krahn
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 8/28/02
Other [] Erosion
Total $105.00 [] 275761 Cert. No. 248101
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
,Job .Address 1270 PHEASANT CREEK DR
Name RUSCH HOMES
Address P O BOX 423
Subdivision 1st Add to Pheasant Creek
Building Permit Number 0097102
Number of Dwelling Units
Fee Required
Owner's Signature
Inspector's Signature
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 09~06~2002
OMRO WI 54963
Lot 44
1
$1oo.~o~
Number of Structures
Fee Paid
Date
Date
~CITY OF OSHKOSH
Project Address
Permit #
Please read the 'following information and sign at the bottom to acknowledge that you haVe read
and agree to comply with these conditions.
1. All habitable rooms must be provided with 8% light and 3.5%-ventilation: ~Bedrooms
located on the second floor or below ground level must be provided .with egress windows
in addition to the,light and ventilati0n requirements. Basement Windowsare also
required tOhave window well areas in accordancewith ILHR 21.03:
Garage spaces shall be separated from the dwelling unit in accordance ~with ILHR 21 ~08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an~ independent testing agency as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required tOlbe taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
o
All prior to the insulationinspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces~ ~
Smoke detectors are required on every floor and within 6! of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubs are required to, have an access panel to motor. The access panel must
be accessible without remOving the finish of the house.
o
All 0verframing must be designed by the tress manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be sUbmitted and approved prior to framing the roof.
°
Truss plans including the tress layout must be provided on site atthe rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building nspecuon for al! ,,mmrolfims':~th pOint loads on them.
Calculations must be ' '~ .... '
prowded for all cantfigvered floors w~th point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
The property owner and ~ipplieant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives,, a minimum of 2"~3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures mUst be maintained until the lawn is established.
11. i All storm sewer inlets must.be protected wi.th approved erosion control devices. Tracking
(i.e. Sediment) must be removed frOm the street at the end of each workday..Repair any
siltation or erOsion damageto adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be pOsted. Additional placards can be
obtained through our department if the cards are misplaced.
!3. All mechanicals must be roughed in prior to requesting therough building inspection. If
on the inspection the mechanicals are not rOughed in, the inspection will fall and a 5;100
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in'the center
of the garage floor and a minimum of a 3' pathway must'be provided around the walls of
the garage. At-the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be On site at the final inspection to provide access to the attic.
16.
The building placard m~st remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy_is not allowed prior to the placard having all of the
final inspection approved Stickers on the backside. If occupancy occurs prior to the
inspections being apprOved daily citations will be issued with no further notice being
given.
17.
All site grading .must be' done in accordance with the approved drainage plan on file in the
public works office,