Loading...
HomeMy WebLinkAbout0097102 BOSHKOSH ON THE WATER Job Address Designer Category Type 1270 PHEASANT CREEK DR 110 - New Single Family CITY OF OSHKOSH BUILDING PERMIT 'APPLICATION AND RECORD Create Date owner RUSCH HOMES Contractor RUSCH HOMES LLC Building O Sign O Canopy (~ Fence (~ Raze No 0097102 08/28/2002 Plan D1-125-0802R Zoning R-1 Class of Const: 8 Unfinished/Basement 1176 Sq. Ft. Rooms 3 Finished/Living 1176 Sq. Ft. ~ Bedrooms 4 Garage 528 Sq. Ft. Baths 3 Foundation ~I Poured Concrete (~ Floating Slab (~) Pier O Concrete Block O Post (~) Treated Wood Occupancy Permit Required Flood Plain No Park Dedication Required # Dwelling Units 1 Height 15 Ft. Stories 1 O Other Height Permit Not Required # Structures 1 Size IRR [] Projection Canopies Signs Use/Nature qSFP,/1 story home with a 2 car attached garage, 14'x14' rear patio, and a 20' wide concrete driveway. of Work HvAc Contractor Electric Contractor Fees: Valuation Issued By: ¢ CONDON TOTAL COMFORT CUMINGS ELECTRIC Plan Approval Plumbing Contractor HANSON QUALITY PLUMBING $75.00 Permit Fee Paid [] Permit Voided $320.00 Park Dedication $100.00 Date 09/06/2002 Final/O.P. 00/00/0000 In the performance of this work I ¢'gree~perform all work pursuant to rules governing the described construction. Signature ~ ~ Date Agent/Owner Address P O BOX 423 Omro WI 54963 - 0000 Telephone Number 685-0241OR mobile OSHKOSH ON THE WATER GRADE STAKE FORM. Name RUSCH HOMES Address Lot 44 Block Subdivision lstAdd to Pheasant Creek Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 08/28/2002 Set By 1270 PHEASANT CREEK DR Grade Stake Number 6806 Create Date 08/28/2002 D.W.G. BK- 573, P- 57 Ward bi. Sidewalk Existing J Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade_established before excavation has commenced. Wisconsin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 Owner's Name RUSCH HOMES Contractor: L~J Con~] Elec'~ RUSCH HOMES LLC Contractor: CUMINGS ELECTRIC Contractor: CONDON TOTAL COMFORT Contractor: L_J Con HANSON QUALITY PLUMBING Lot Area Building Address 1270 PHEASANT CREEK DR District(s) Permit No. WISCONSIN UNIFORM BUILDING PERMIT APPLICATION [] Constr [] HVAC [] Elec [] Plbg Application No. 0097102 ParCe No. [] Erosion [] Other: Mailing Address P O BOX 423 Lic,/Cert # Mailing Address 879882 P O BOX 423 OMRO WI 54963- 0000 Omro WI 54963- 0 Mailing Address PO BOX 749 1414 COUNTY RD JJ NEENAH WI 54957 -749 Mailing Address 11 BLACKBURN ST RIPON Wl54971 -184 Mailing Address BLUEMOUND RD APPLETON WI 54914 -0 Telephone No. 685-0241 Telephone No. 685-0241ORm( Telephone No. 231-5946 Telephone No. (920)748-5050 Telephone No. 730-0205 1/4, 1/4,Section ,T N,R E(or)W Subdivision Name 1st Add to Pheasant Creek JLot No. 44 Block No. Front Rear Left Right New [] Repair Single Family Entrance Panel Forced Air Furnace Fuel [] Alteration [] Raze Two Family Size: 200 am [] Radiant Baseboard or Panel Garage Service: [] Heat Pump Space Htg [] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg [] Other: [] Underground [] Central Air Conditioning Dwelling unit will have 3 kilowatt or [] Site Constructed Concrete Other more installed electric space heating equil Infiltration control option is: [] Full sealing Unfinished [] Manufactured Masonry Treated Wood Sewer of joints. [] Blower door test. [] Exterior Basement 1176 Sq. ft. [] Municipal ~ir infiltration barder. Living Area 1176 Sq. ff. 1-Story Other [] Septic [] 2-Story Permit No. Envelope 22451 BTU/HR Garage 526 Sq. ft. [] Other [] Seasonal Infiltration 14394 BTU/HR [] Permanent [] Municipal Utility [] Plus Basement [] Other [] Private On-Site Well $130,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express ~_~l;~d,~o~Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE /Z..~ DATE SIGNED This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revocation of this permit or other penalty see standard conditions of approval NOTE: ALL HABITABLE ROOMS ARE REQUIRED TO BE PROVIDED WITH 8% LIGHT AND 3.5% VENTILATION [] Town [] Village [] City [] County L_J State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name Nicole Krahn Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 8/28/02 Other [] Erosion Total $105.00 [] 275761 Cert. No. 248101 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER ,Job .Address 1270 PHEASANT CREEK DR Name RUSCH HOMES Address P O BOX 423 Subdivision 1st Add to Pheasant Creek Building Permit Number 0097102 Number of Dwelling Units Fee Required Owner's Signature Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD Date 09~06~2002 OMRO WI 54963 Lot 44 1 $1oo.~o~ Number of Structures Fee Paid Date Date ~CITY OF OSHKOSH Project Address Permit # Please read the 'following information and sign at the bottom to acknowledge that you haVe read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5%-ventilation: ~Bedrooms located on the second floor or below ground level must be provided .with egress windows in addition to the,light and ventilati0n requirements. Basement Windowsare also required tOhave window well areas in accordancewith ILHR 21.03: Garage spaces shall be separated from the dwelling unit in accordance ~with ILHR 21 ~08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an~ independent testing agency as having a minimum fire-resistive rating of 20 minutes. All drywall joints are required tOlbe taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. o All prior to the insulationinspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces~ ~ Smoke detectors are required on every floor and within 6! of all bedrooms. The smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to, have an access panel to motor. The access panel must be accessible without remOving the finish of the house. o All 0verframing must be designed by the tress manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be sUbmitted and approved prior to framing the roof. ° Truss plans including the tress layout must be provided on site atthe rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building nspecuon for al! ,,mmrolfims':~th pOint loads on them. Calculations must be ' '~ .... ' prowded for all cantfigvered floors w~th point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and ~ipplieant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives,, a minimum of 2"~3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures mUst be maintained until the lawn is established. 11. i All storm sewer inlets must.be protected wi.th approved erosion control devices. Tracking (i.e. Sediment) must be removed frOm the street at the end of each workday..Repair any siltation or erOsion damageto adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be pOsted. Additional placards can be obtained through our department if the cards are misplaced. !3. All mechanicals must be roughed in prior to requesting therough building inspection. If on the inspection the mechanicals are not rOughed in, the inspection will fall and a 5;100 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in'the center of the garage floor and a minimum of a 3' pathway must'be provided around the walls of the garage. At-the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be On site at the final inspection to provide access to the attic. 16. The building placard m~st remain on the patio door or on a kitchen window until occupancy is approved. Occupancy_is not allowed prior to the placard having all of the final inspection approved Stickers on the backside. If occupancy occurs prior to the inspections being apprOved daily citations will be issued with no further notice being given. 17. All site grading .must be' done in accordance with the approved drainage plan on file in the public works office,