HomeMy WebLinkAbout0097675 BOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type
1260 PHEASANT CREEK DR
110 - New Single Family
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Create Date
Owner RUSCH HOMES
Contractor RUSCH HOMES LLC
· Building O Sign (~ Canopy (~ Fence (~ Raze
No 0097675
09/25/2002
Plan D1-140-0902R
Zoning Class of Const: 8
Unfinished/Basement 727 Sq. Ft. Rooms 6
Finished/Living 1516 Sq. Ft. Bedrooms 3
Garage 480 Sq. Ft. Baths 3
Foundation · Poured Concrete (~ Floating Slab (~ Pier
O Concrete Block (~) Post O Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units 1
Height 25 Ft.
Stories 2
Other
Size IRRG
[] Projection J
Canopies 0
Signs 0
Height Permit Not Required
# Structures 1
Use/Nature NSFR/ New 2 story with 2 car attached garage and 14' x 14' patio. Driveway willbe 20' wide at the front property line.
of Work
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By: ~
CONDON TOTAL COMFORT
Plumbing Contractor HANSON QUALITY PLUMBING
CUMINGS E L~I~,
~~~ Approve,
$75.00 Permit Fee Paid
$380.00 Park Dedication $100.00
Date 10/01/2002 Final/O.P. 00/00/0000
[] Permit Voided
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
Signature Date
Agent/Owner
Address P O BOX423 Omro WI 54963 - 0000 Telephone Number
685-0241OR mobile
OSHKOSH
ON THE WATER
Name RUSCH HOMES
GRADE STAKE FORM
Address 1260 PHEASANT CREEK DR
Lot 43 Block
Subdivision lstAdd't PHEASANT CREEK Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 09/26/2002 Set By
Grade Stake Number 6824
Create Date 09/25/2002
Ward
D.W.G. BK-582, P-76
L_L Sidewalk Existing
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have t~he gra~d~e~s~a'blished before excavation
has commenced.
Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN UNIFORM
BUILDING PERMIT
APPLICATION
[] Constr [] HVAC [] Elec [] Plbg
Application No.
0097675
Parce No.
[] Erosion [] Other:
Owner's Name
RUSCH HOMES
Contractor: L~J Con~] Bec[] HVAC Id Plbg
RUSCH HOMES LLC
Contractor: Id Con ~J Elec [_J HVAC~J Plbg
CUMINGS ELECTRIC
Contractor: I I Con b_d Elec~d HVAC [] Plbg
3ONDON TOTAL COMFORT
Contractor:L_j con [] Elec[~ HVAC[] Plbg
HANSON QUALITY PLUMBING
Lot Area
Lic/Cert #
879882
Lic/Cert #
170792
Lic/Cert #
3202
Lic/Cert #
Mailing Address
P.O. BOX 423
eMRO WI 54963- 0000
Mailing Address
P O BOX 423
emro WI 54963- 0
Mailing Address
PO BOX 749 1414 COUNTY RD JJ NEENAH
WI 54957 - 749
Mailing Address
11 BLACKBURN ST RIPEN
WI 54971 - 184
Mailing Address
550 N BLUEMOUND RD
APPLETON WI 54914 -0
Sq.
1/4,
i Telephone No.
Telephone No.
685-0241OR m(
Telephone No.
231-5946
Telephone No.
(920)748-5050
Telephone No.
730-0205
1/4,Section ,T N,R E(or)W
Building Address
1260 PHEASANT CREEK DR
District(s) Permit No.
ISubdivi,,s, ion Name
1st Add t PHEASANT CREEK
ILot No.
43
Block No.
Front Rear Left Right
New [] Repair Family
[] Alteration [] Raze Two Family
Garage
[] Addition [] Move [] Other (print):
[] Other:
[] Site Constructed
Unfinished [] Manufactured
Basement 727 Sq. ft.
Living Area 1516 Sq. ff. 1-Story
Garage 480 Sq. Other
Plus Basement
The applicant agrees to comply with all applicable codes
the permit creates no legal liability, express or
APPLICANT'S SIGNATURE
Entrance Panel
ISize:
Service:
[] Overhead
[] Underground
Concrete
Masonry
Treated Wood
Other
[] Seasonal
[] Permanent
[] Other
Forced Air Furnace
[] Radiant Baseboard or Panel
[] Heat Pump
[] Boiler
Central Air Conditioning
Other
Sewer
[] Municipal
[] Septic
Permit No.
[] Municipal Utility
[] Private On-Site Well
Fuel
Space Htg
Water Htg
~g unit will have 3 kilowatt or
more installed electric space heating equip.
Infiltration control option is: [] Full sealing
of joints. [] Blower door test. [] Exterior
air infiltration barrier.
Envelope 24287 BTU/HR
Infiltration 14107 BTU/HR
$120,000.00
ordinances and with the conditions of this permit, understands that the issuance of
or municipality; and certifies that all the above information is accurate.
DATE SIGNED
This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS
revocation of this permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
[] Town [] Village [] City [] County J J State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name JOHN ZARATE
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 9/25/02
Other [] Erosion
Total $105.00 [] 275813 Cert. No. 70330
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
,Job Address 1260 PHEASANT CREEK DR
Name RUSCH HOMES
Address P.O. BOX 423
Subdivision l stAdd't PHEASANT CREEK
Building Permit Number 0097675
Number of Dwelling Units 1
Fee Required $100.00
Owner's Signature
Inspector's Signature
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 10/01/2002
OMRO WI 54963
Lot 43
Number of Structures
Fee Paid
Date
Date
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address IX~ P/-/~ASA, ~7- C~ Er:/C Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All'habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground 'level must be provided With egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
All penetrations in exterior walls 'must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required On every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the truss layout must be provided on site atthe rough building
inspection. In addition to the tress plans, microlam calculations-must be provided on site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
11.
Ail storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities. '
12.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16.
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd flo~(.._.., .~