HomeMy WebLinkAbout0097106 BOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type
1240 PHEASANT CREEK DR
110 - New Single Family
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Owner RUSCH HOMES
Contractor RUSCH HOMES LLC
Create Date
Building (~ Sign (~) Canopy (~ Fence (~ Raze
No 0097106
09/04/2002
Plan Dl-131-0902R
Zoning R-1 Class of Const: 8
Unfinished/Basement 478 Sq. Ft. Rooms 3
Finished/Living 1774 Sq. Ft. Bedrooms 4
Garage 672 Sq. Ft. Baths 3
Foundation · Poured Concrete (~ Floating Slab ~) Pier
(~ Concrete Block (~ Post (~ Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units 1
Height 16 Ft.
Stories Quad-level
Other
Height Permit Not Required
# Structures 1
Size IRR
[] Projection
Canopies
Signs
Use/Nature NSFR/Quad-level home with a 2 car attached garage, 20' wide concrete driveway, and a 14'x14' rear at grade patio.
of Work
HVAC Contractor
Electric Contractor
Fees: Valuat7
Issued By: ~
CONDON TOTAL COMFORT
CUMINGS ELECTRIC
Plumbing Contractor HANSON QUALITY PLUMBING
$90,000.00 Plan Approval $75.00 Permit Fee Paid $350.00 Park Dedication $100.00
Date 09/06/2002 Final/O.P. 00/00/0000
[] Permit Voided
In the performance~ .w/el~J~agree to perform all work pursuant to rules governing the described COnstruction.
Signature ~,-, ~r,,,,~ Date
Agent/Owner
Address P O BOX 423 Omro WI 54963 - 0000 Telephone Number
685-0241OR mobile
OSHKOSH
ON THE WATER
Name RUSCH HOMES
GRADE STAKE FORM
Address 1240 PHEASANT CREEK DR
Lot 41 Block
Subdivision 1ST Add to Pheasant Creek Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 09/05/2002 Set By
Grade Stake Number 6813
Create Date 09/04/2002
D.W.G. BK- 573, P- 62,63
Ward
~_Sidewalk Existing
Department of Public Works
I, the undersigned, owner or agent of the above desCribed Property agree to have the grade.e~ta, blished before excavation
has commenced.
WisconSin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
WISCONSIN 'UNIFORM
BUILDING PERMIT
APPLICATION
[] Constr [] HVAC [] Elec [] Plbg
Application No.
0097106
Parce No.
[] Erosion [] Other:
Owner's Name
RUSCH HOMES
Contractor: ~ Con~] Elec'~ HVAC ~J Plbg
RUSCH HOMES LLC
Contractor: ~ Con ~ ElecL_J HVAC~J Plbg
CUMINGS ELECTRIC
Contractor: L__J Con ~_~ Elec~J HVAC [] Plbg
3ONDON TOTAL COMFORT
Contractor:[~ Con [] Elec[~ HVAC[] Plbg
HANSON QUALITY PLUMBING
Lot Area
Building Address
1240 PHEASANT CREEK DR
Lic/Cert #
879882
Lic/Cert #
170792
Lic/Cert #
3202
Lic/Cert #
Mailing Address
P O BOX 423
OMRO WI 54963- 0000
Mailing Address
P O BOX 423
Omro WI 54963 - 0
Mailing Address
PO BOX 749 1414 COUNTY RD JJ NEENAH
WI 54957 - 749
Mailing Address
11 BLACKBURN ST RIPON
WI 54971
Mailing Address
550 N BLUEMOUND RD
APPLETON WI 54914
Sq. ft.
1/4,
Telephone No.
685-0241
Telephone No.
685-0241OR m(
Telephone No.
231-5946
Telephone No.
- 184 (920) 748-5050
Telephone No.
- 0 730-0205
1/4,Section ,T N,R E(or)W
Subdivision Name Lot No,
1ST Add to Pheasant Creek 41
Block No.
District(s) Permit No. Front Rear Left Right
New [] Repair Single Family Entrance Panel Forced Air Furnace
Fuel
[] Alteration [] Raze Two Family Size: 200 am [] Radiant Baseboard or Panel
Garage Service: [] Heat Pump Space Htg
[] Addition [] Move [] Other (print): [] Overhead [] Boiler Water Htg
[] Other: [] Underground Central Air Conditioning Dwelling unit will have 3 kilowatt or
[] Site Constructed Concrete more installed electric space heating equip.
Infiltration control option is: [] Full sealing
Unfinished [] Manufactured Masonry Sewer of joints. [] Blower door test. [] Exterior
Basement 478 Sq. ft. Treated Wood [] Municipal air infiltration barrier.
Living Area 1774 Sq. ft.. 1-Story Other [] Septic
I ~r_~E~] 2-Story Permit No. Envelope 24090 BTU/HR
Garage 672 Sq. ft. Other [] Seasonal Infiltration 13782 BTU/HR
Quad-level [] Permanent [] Municipal Utility
Plus Basement [] Other [] Private On-Site Well $140,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express, or i~ie/d~n~he Department or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE ~'~.,, ~,~-,'~,,~ DATE SIGNED
This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS revocation of this permit or other penalty
see standard conditions of approval
[] Town [] Village [] City [] County bJ State of:
City Of Oshkosh
Municipality Number of Dwelling Location:
7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name Nicole Krahn
Inspection Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 9/4/02
Other [] Erosion
Total $105.00 --I 275765 Cert. No. 248101
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
Job Address 1240 PHEASANT CREEK DR
Name RUSCH HOMES
Address P O BOX 423
Subdivision 1ST Add to Pheasant Creek
Building Permit Number 0097106
Number of Dwelling Units
Fee Required
Owner's Signature
Inspector's Signature
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 09/06/2002
OMRO WI 54963
Lot 41
1 Number of Structures
$100.00 Fee Paid
Date
Date
51'
2.8~
Project Address
.'CITY OF OSHKOSH
STANDARD. CONDITIONS OF APPROVAL
Please read the follOwing information and sign at the bottom to acknOwledge that you haveread
All habitable rooms must be provided with 8% light and. 3.5% ventilation. Bedrooms
located on the second floor or below ground level must beprovided with egress windows
in addition.to the light and ventilation requirements.: Basement windOws are alsO
required to'have windoTM Well areas in accordance with ILHR21~03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly betWeen~the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimUm fire-resistive rating of 20
minutes. All drywall joints areYeqUired tObe taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood 'or
drywall with the joints, staggered.
3. All penetrations in exterior'walls must ! prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts~ and holes in the
return air spaces. ~
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The'access panel must
be accessible.without removing the finish of the house.
6.. All overframing must be designed by the truss manufacturer, according to standards set
by the tress plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the rOof.
8. Truss plans including the tress layout must be provided on site at'the rough building
inspection. In addition to the tress plans, microlam calculations must be provided on site
at the rough building inspection for all micmlam~s..~th point loads on them.
Calculations must be
and TJI'S must be designed for the cantilevered areas.
with point loads. Floor trusses
10.
11.
1¸2.
13.
14.
15.
16.
17.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be~m~tatned, tmtfi:'~e~lya~ Ds established. ~
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways-resulting from land
development or disturbing activities.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patiO door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged:
Attached is a copy of the final inspection checklist. Atthe final inspection all items on
this list must be completed to avoid the $100 re-inspeCtion fee per insPection.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the fmal inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are notto be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic,
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allOWed prior to the placard having all of the
final inspection approved stickerS on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
:given.
Ail site grading must be done in accordance with the.approved drainage plan on file in the
public Works office, 3rd floor.