Loading...
HomeMy WebLinkAbout0099676-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type 3230 BELLFIELD DR CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner CREATIVE CUSTOM HOMES Contractor CREATIVE CUSTOM HOMES, INC 110 - New Single Family · Building O Sign O Canopy (~ Fence O Raze No 0099676 Create Date 01/02/2003 Plan D1-186-1202R Zoning R-1 Class of Const: Unfinished/Basement 138 Sq. Ft. Rooms 7 Finished/Living 1824 Sq. Ft. Bedrooms 3 Garage 450 Sq. Ft. Baths 2 Foundation · Poured Concrete (~ Floating Slab (~) Pier (~ Concrete Block C) Post Height 19 Ft. Stories Bi-level Other O Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures I Size Irrg [] Proje~ion I Canopies 0 Signs 0 Use/Nature ~ISFPJ New single family Bi-level with 2 car attached garage. NO DECK OR PATIO. Driveway will be 18' wide. of Work HVAC Contractor BAY AREA SERVICES INC Plumbing Contractor HANSON QUALITY PLUMBING Electric Contractor VAN ERT ELECTRIC Fees: Valuation $89,400.00 Plan Approval $75.00 Permit Fee Paid $350.00 Park Dedication $100.00 Issued By: Date 02/03/2003 Final/O.P. 00/00/0000 [] Permit Voided J In the performance of this work I agree to j~erform all work pursuant to rules governing the described construction. Signature ,~¢~1~'.~11~ ~,'~,~-Jlllll~ D a t e ¢,~. --~1,~-~,~_~ '~;;7 Agent/Owner Address 1087 VELP AVE GREEN BAY WI 54303 - 0000 Telephone Number 434-4105 OSHKOSH ON THE WATER GRADE STAKE FORM Name CREATIVE CUSTOM HOMES Address Lot 57 Block Subdivision 1ST ADD'T VILLAGE GREEN Zone Street Number Lot Dimensions 3230 BELLFIELD DR Grade Stake Number 6870 Create Date 01/02/2003 L._J Sidewalk Existing Ward Building Grade Elevation Stakes Set At Site 01/06/2003 Set By D.W.G. BK - 579, P - 58 Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. Wisconsin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 Owner's Name CREATIVE CUSTOM HOMES [] Constr WISCONSIN UNIFORM JApplication No. BUILDING PERMIT J 0099676 APPLICATION IParcel No. [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address 1087 VELP AVE Telephone No. GREEN BAY WI 54303- 0000 Contractor: [~J Con~] Elec'E~] HVAC ~J Plbg ;REATIVE CUSTOM HOMES, INC Contractor: L~ Con ~J Bec L_J HVAC~J Plbg VAN ERT ELECTRIC Contractor: L_J Con U Elec~J HVAC [] Plbg BAY AREA SERVICES INC Contractor:L_J Con [] Elec[~ HVACr~ Plbg HANSON QUALITY PLUMBING Lot Area Building Address 3230 BELLFIELD DR Zoning District(s) Permit No. Lic/Cert # Mailing Address Telephone No. 679085 1087 VELP AVE GREEN BAY WI 54303 - 0 434-4105 Lic/Cert # Mailing Address Telephone No. 170921 2000 PROGRESS WAY KAUKUANA WI 54130 - 0 920-766-3888 Lic/Cert # Mailing Address Telephone No. 5180 1449S BROADWAY GREEN BAY WI54304 -0 920-435-7111 Lic/Cert # Mailing Address Telephone No. 550 N BLUEMOUND RD APPLETON WI 54914 -0 730-0205 Sq. ft.I 1/4, 1/4;Section ,T N,R E(or)W Subdivision Name Lot No. Block No. 1ST ADD T V LLAGE GREEN 57 Front Rear Left Right New [] Repair Single Family Entrance Panel [] Alteration [] Raze Two Family Size: Garage Service: [] Addition [] Move [] Other (pdnt): [] Overhead [] Other: [] Underground [] Site Constructed Concrete Unfinished [] Manufactured Masonry Sewer Basement 138 Sq. ft. Treated Wood [] Municipal Other Living Area 1824 Sq. ft. [] Septic Permit No. Garage 450 Sq. ff. 1-Stow [] 2-Story [] Other [] Seasonal Bi-level [] Permanent [] Plus Basement [] Other Forced Air Furnace [] Radiant Baseboard or Panel [] Heat Pump [] Boiler Central Air Conditioning Other [] Municipal Utility [] Private On-Site Well Fuel Space Htg Water Htg unit will have 3 kilowatt or more installed electric space heating equip. Infiltration control option is: [] Full sealing of joints. [] Blower door test. [] Exterior air infiltration harder. Envelope 21979 BTU/HR Infiltration 11457 BTU/HR $114,900.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, expr~r implied, on~,Dep~tment or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE ~/~,~,/~'.,.~ ..~~ DATE SIGNED ¢~,,~ This permit is issued~., suant to'the following conditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET [] Town [] Village [] City [] County L_J state of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZAP, ATE Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 1/2/03 Other [] Erosion Total $105.00 275791 Cert. No. 70330 SBD-5823(R. 07/92) OSHKOSH ON THE WATER Job Address 3230 BELLFIELD DR Name CREATIVE CUSTOM HOMES Address 1087 VELP AVE Subdivision 1ST ADD"r VILLAGE GREEN Building Permit Number 0099676 Number of Dwelling Units 1 Fee Required $100.00 Owner's Signature Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD Date 02/03/2003 GREEN BAY WI 54303 Lot 57 Number of Structures Fee Paid Date Date ,~ ~-~ ~ONDITIONS OF APPROVAL Pro}eet Address Permit# Please read the folloWing information and sign atthe bottOm to aCknOwledge that yOU have read and agree to Comply with these conditions. ":" ' 3.5% Ventiiafion~ Be 1. rooms must be · ~ ght and drooms located on the ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also i~eqUired ~0 have WindoTM well areas in accordance with ILHR'21~03~ 2. Garage spaces shall be u~t in acc°rdance The dOor and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent te~ting agency as having a minimum fire-resistive ratin~ of 20 minutes. ~ drywall joints are required to be taped/sealed unless the joints are fitted so that the gap ~s no more than a ~dimes thickness (1/20-inch) and backed by sOlid wood or drywall with the joints staggered. ' penetrations in'exterior walls mUst be Sealed inspection. This includes hOles in the top and bottom plates, gaps around heating ducts; and holes in the return air spaces. 4. are on o P Th tubs are req' access anel to motor, e access panel must accessible without removing the f'mish of the house. o o 91 ~"- ' Ciil6~tiati0hs must be provided and TJI'S ~us{ be designed for the cantilevered areas. All overframing must be designed by the truss manufacmrer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the truSs layout must be provided on site at the rOugh building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building insPection for all microlams with point loads on them. point loads. Floor trusses 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition toa minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintaine~ until the lawn is established. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work oiders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be plaCed in the center of the garage floor and a minimum o£a 3T pathway must be provided around the walls of the garage. At the fmal inspection no fumiture or personal belongings are allowed in the houSe. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in Place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no furthernofi.~e.b.~ng given. - 17. All site grading must be done in aCcordance with the approved drainage plan on file in the public works office, 3rd floor.