Loading...
HomeMy WebLinkAbout0135056-Plumbing (PIMS, water main)� �� ;'Vr1 : � .�, � {i , Fixture Listing , �i Date:March 5,2009 Name: Carl Bowers&Sons Construction Project:Future Single Family Condos Street: Street: 3408-3496 W 20th Ave Condos City: City: Oshkosh,WI Non Public Use Fixtures Hot Cold Total I Automatic Clothes Washer 1.00 1.00 1.50 1 Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1/2"diameter .00 6.00 6.00 1 Kitchen Sink 1.00 1.00 1.50 1 Laundry Tray, 1 or 2 comparhnent 1.00 1.00 1.50 2 Bathtub,lavatory and water closet-FT group 4.00 7.00 8.00 Total Water Supply Fixture Units 8.00 16.00 19.50 13.7 Gallon per minute demand of the building.Predominatly Flush Tank 24.7 Pressure available for uniform loss.For the table use-25.0 Maximun Allowable load for Crosslinked Polyethylene(Pex)Tubing ASTM F876 Nominal Size 1/2 5/8 3/4 I 1 1/4 1 1/2 2 2 1/2 3 4 Actual I.D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0 Value of C 150 150 150 150 I50 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 4.5 6.5 9 15 22 31 53 0 0 0 Maximum FM WSFU 0 0 0 5 7 15 56 0 0 0 Maximum FT WSFU 5 8 11.5 21.5 35 57 140 0 0 0