Riverside Engineering & Design
1740 Riverside Drive
P. O. Box 255
Suamico, WI 54173
Ref: Plumbing Plan Approval:
Dear Sirs,
Kyria Day Care
1783 S. Washburn St., Oshkosh, WI
Plan ID# F6-333-1008-P
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin
Administrative Code, the plumbing plans and specifications are approved contingent upon
compliance with the stipulation(s) noted below.
1. Limit developed length from point of vent to weir of trap served to COMM 82.31
table 82.31-1
2. Drain vent systems require one pipe size increase for building drain that also serves
as vent per COMM 82.31 table 82.30-3
3. Only fixtures of one drainage fixture unit or less may discharge into a wet vent
serving another fixture per COMM 82.31
4. The grease trap calculation includes only one compartment of the kitchen sink and
two dishwasher discharges. The riser diagram includes both sink compartments
and will require increased capacity in the grease trap. COMM 82.34
5. Installation of an air admittance valve requires testing of the device before
installation per COMM 82.21
6. Design of a vertical wet vent shall include only two wall outlet fixtures per COMM
82.31
7. Full size cleanout access shall be provided for all horizontal building drain per
COMM 82.35
8. Based on available pressure, the calculated "A" value for the water distribution will
be 13 psi and will limit the dfu load on 3/" PEX to no more than 10 wsfu. COMM
82.40
9. Based on requirements from City of Oshkosh Public Works Department, the sewer
and water service connections will be made off Allerton Drive and not S. Washburn
St..
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. Anew application accompanied by full examination
fees shall be filed and an updated approval received before work may commence.
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or
any damage that may result in or after installation. The City of Oshkosh reserves the right to
order changes or additions should conditions arise making this necessary. It shall be
necessary for the installing plumber to obtain a plumbing permit from the City of Oshkosh
before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Richard Wood,