Loading...
HomeMy WebLinkAbout0100040-BuildingOSHKOSH ON THE WATER Job Address 4035 SHARRATT DR CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner SHOWCASE CUSTOM HOMES INC Designer Contractor SHOWCASE CUSTOM HOMES INC Category 110 - New Single Family Type I~ Building O Sign O Canopy O Fence O Raze No 0100040 Create Date 01/30/2003 Plan E1-008-0103R Zoning R-1 Class of Const: 8 Unfinished/Basement 1400 Sq. Ft. Rooms 6 Height Finished/Living 1400 Sq. Ft. Bedrooms 3 Stories 1 Garage 672 Sq. Ft. Baths 2 Foundation 0 Poured Concrete (~ Floating Slab C) Pier C) Other (~ Concrete Block (~) Post (~) Treated Wood Occupancy Permit Required Flood Plain No Park Dedication Required # Dwelling Units 1 17 Ft. Size lrrg [] Projection Canopies Signs Height Permit Not Required # Structures I Use/Nature NSFR/ New single family I story with 2 car attached garage and 10' x 12' patio. Driveway shall be a maximum of 24' wide at the front of Work property line. HVAC Contractor BREWER HEATING Plumbing Contractor P&S PLUMBING Electric Contractor SCHOMMER ELECTRICAL CON Fees: Valuation ~, ,$91,100.00 Plan Approval ,$75.00 Permit Fee Paid [] Permit Voided l $356.00 Park Dedication $100.00 Date 03/04/2003 Final/O.P. 00/00/0000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner Address 2755 ALGOMA BLVD OSHKOSH WI 54901 - 0718 Telephone Number 235-5610/c-379-9046 OSHKOSH ON THE WATER GRADE STAKE FORM Name SHOWCASE CUSTOM HOMES INC Address 4035 SHARRATT DR Lot 86 Block Subdivision NORTH PARK ESTATES Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 02/03/2003 Set By D.W.G. BK - 586, P - 73 Grade Stake Number 6890 Create Date 01/3012003 Ward bJ Sidewalk Existing Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. ,~~ Wisconsin Department of Indu.~try, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0100040 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 ~~ ~ [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Owner's Name Mailing Address Telephone No. SHOWCASE CUSTOM HOMES IN(; 2755 ALGOMA BLVD Oshkosh WI 54901 - 0000 Contractor: ~ Con~] Elecl~ HVAC I__J Plbg Lic/Cert# Mailing Address lTelephone No. SHOWCASE CUSTOM HOMES INC 2201 2755 ALGOMA BLVD OSHKOSH WI 54901 - 718 ~235-5610/c-379 Contractor: [__l Con b~J Elec bd HVACLJ Plbg Lic/Cert # Mailing Address Telephone No. SCHOMMER ELECTRICAL CON 170465 N 164 TWO MILE ROAD APPLETON WI 54914 - 9121 (920) 731-2299 Contractor: ~ Con b~ Bec~ HVAC [] Plbg Lic/Cert # Mailing Address Telephone No. BREWER HEATING 4220 N8804 N DOUGLAS STREET RIPEN WI 54971 - 0 (920)748-6494 Contractor:l ~ Con [] Elec[] HVAC[] Plbg Lic/Cert Cf Mailing Address Telephone No. P&S PLUMBING PO BOX2153 APPLETON WI 54913 -0 734-3912 ~" :':':~ ::~%~'~Lot Area ~!~i~ Sq. ft. 1/4, 1/4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 4035 SHARRATT DR NORTH PARK ESTATES 86 Zoning District(s) Zoning Permit No. Front I Rear Left Right Setbacks b~J New [] Repair [] Single Family Entrance Panel L~J Forced Air Furnace Fuel Nat. L.P. OilElec. Solid Sola [] Alteration [] Raze E~ Two Family Size: 200 amp [] Radiant Baseboard or Panel , Gas , [] Addition Garcge Service: [] Heat Pump Space Htg [] [] [] [] [] [] [] Move [] Other (print): ~ Overhead [] Boiler Water Htg [] [] [] [] [] [] Underground [] Central Air Conditioning * ~J Dwelling unit will have 3 kilowatt or [] Other: ' ~ ~ [] Other, more installed electric space heating equip. ~~% [] Site Constructed __l Concrete ~'~~~ Infiltration control option is: [] Full sealing Unfinished [] Manufactured ~ Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 1400 Sq. ft. ~ ~ Treated Wood [] Municipal air infiltration barrier. Living Area 1400 Sq. ft. "E~" 1-storyd Other [] 2-Story ~¥ [] Septic Permit No. Envelope 25695 BTU/HR Garage 672 Sq. ft. [] Other [] Seasonal :~¢.~~ Infiltration 17136 BTU/HR [] Permanent [] Municipal Utility [] Plus Basement [] Other [] Private On-Site Well $105,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, expre~ss or implied, on tb.e Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE ~¢¢./.I p;rmit)~/[~'/ //-')~/~/~ DATE SIGNED Tl~/fs ~ issue"~p~lr;u;nt to the following conditions. Failure to comply may result in sbspension or APPROVAL CONDITIONS re~/ocation bf this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET ~ [] Town [] Village [] City [] County bd State of: Municipality Number of Dwelling Location: ~, City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 .~ Construction '~ HVAC Name JOHN ZARATE Inspection [~_ Electrical Wis. Permit Seal $30.00 [] Plumbing Date 1/30/03 Other [] Erosion Total $105.00 L--J 288710 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address Name Address Subdivision Building Permit Number Number of Dwelling Units Fee Required Owner's Signature Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD 4035 SHARRATT DR SHOWCASE CUSTOM HOMES INC 2755 ALGOMA BLVD NORTH PARK ESTATES 0100040 1 $100.00 Date 03/04~2003 Oshkosh WI 54901 Lot 86 Number of Structures Fee Paid Date Date OZHKOZH ON THE WATEI~ City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address:4035 SHARRATT DR Submitted By:SHOWCASE CUSTOM HOMES Plan Number:E 1-006-0103R Reviewed By: JZ Phone: 920-236-5119 Date Reviewed: 1/31/2003 Phone Number: 235-5610 [-] Mailed ["-] Faxed E~] Delivered Date: Result of Plan Review: [~] Conditionally Approved E~] Withheld Pending Approval of Additional Information ['-1 Not-Approved, Plans Returned for Revisions Conditions Noted on Plan Review 1) All required smoke detectors shall be indicated on the floor plan for any future plans. 2) Fire seperation between the garage and living space shall be indicated on the floor plan for any future plans. 3) The proposed patio shall be installed prior to occupancy or a code compliant exit installed for the rear patio doors. 4) Bathroom exhaust fans shall be indicated on all future plans. BUILDABLE AREA OUTLINE \ HOUSE 117.26' GARAGE 1 28'-10 ]./;:'- Iv 128.18' .. [:~ 46'-2 1/2' ~:3,Id3WAY OR O1HER ~ 14L~DM30 BY LOCAL ~. CONSt~? LL~ 21.125. il~ FOR ANY ~JESIK~ ! z~ 1-~--o~ i SHOWCASE HOMES 21.13. )M) LOCN. BUI. DING OF'ritE SHARRATT DRIVE LOT 86 NORTH PARK ESTATES OF OSHKOSH Proj :Address ~9.~' ~'~rz-~ ~ Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply ~th these conditions. 1. All habitable rooms must be provided with 8% li located on the secondfloor ~'-' .......... or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also. required to ha~e window well areas in accordance ~wi. ~'~th I.~.~!~:03~ 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and fr~..~.~ly between the dwelling unit and an attached garage shall be labeled byan independent testing agency as having a minimum fire-resistive rating of 20 · minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness ( 1/20-inch) and backed by solid wood or drywall with the joints staggered. 3. penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. ~ are required on every floor and within 6' 0£ all bedrooms. The sm0ge detectors are required to be hardwired and interconnected? Hydromassage mbs are required to have an access panel to motor. The access panel must be accessible withoutremoving the finish of the house 6. All overframing must be designed by the tress manufacturer, according to standards set bY the truSs Plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the tress layout must be provided on site at the, rough building inspection~ In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. Calculations must be provided for all cantilevered floors.w_i, th point i0ads. Floor trusses and TJI's 'must be designed for the cantilevered areas. 10. The property owner' and applicant is responsible for comPliance with ILHR 21.125 (Erosion Control). Wh® inst~iling ~edess~dri3~s}' a minimum of 2"-3" diamete~ ~t0ne is' required in addition to a minimum'of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is 'established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i:e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and'drainageways resulting from land develOpment or dis~urb~iiig 12. he building placard must be posted on s~te at all times. Once the rough ~aming is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work oiders will be posted. Additional placards'can be obtained through our department if the cards are misplaced. 13. All mechanicals muSt be roughed in prior to requesting the rough building' insPeCtion. If ........ on the inspection the mechanicals are not roughed in, the inspection will fail ah~I'~ $i 00 ~ ......... re-inspection fee will be charged. 14. Attached is a copy of the final inspection Ch~Cldlst. this list must be completed to avoid the $100 re-inspection fee per inspedtionl 15. When requesting final i'nspections please note that a minimum Of 2daYs n0ti~e i~ n~e~ded from the time the inspection is ready. Furniture is only allowed to be placed in' the"~-ntdi~ of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspecti°n to provide accesS to the attiC. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. O~cupancy is hot all0'Vi/ed priO~ tO the Placard haVing ai~' 6fth~ final inspection approved stickers on' the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further 'notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in'the public works office, 3rd floor.