HomeMy WebLinkAbout0133809-BuildingCITY OF OSHKOSH No 133809
OSHKOSH
ON THE WATER
Job Address 1902 ROOSEVELT AVE
BUILDING PERMIT -APPLICATION AND RECORD
Designer
Category 110 -New Single Family
Owner HRS DEVELOPMENT INC
Contractor SALZER SIDING
Create Date 11/04/2008
Plan 038-1108
Type ~ Building ~ Sign ~ Canopy ~ Fence ~ Raze
Zoning R1 Class of Const: 8 Size irreg
Unfinished/Basement 1306 Sq. Ft. Rooms 3 Height 16 Ft. ^ Projection
Finished/Living 1306 Sq. Ft. Bedrooms 3 Stories 1 Canopies
Garage 576 Sq. Ft. Baths 2 Signs
Foundation ~ Poured Concrete ~ Floating Slab ~ Pier ~ Other
0 Concrete Block ~ Post ~ Treated Wood
Occupancy Permit Required Occupancy Fee $0.00 Flood Plain No Height Permit Not Required
Park Dedication Not Required # Dwelling Units 1 # Structures 1
Use/Nature
of Work
New Single Family Residence with Detached Garage /One Story House, 1306 sf, 3 bed, 2 bath, 576 sf Detached Garage, 14x15 patio.
HVAC Contractor SOLAR HEATING SERVICES LLC
Electric Contractor SECKAR ELECTRIC CO INC
Fees: Valuation $85,000.00 Plan Approval
issued By:
$75.00 Permit Fee Paid $373.00 Park Dedication $0.00
Date 11/05/2008 Final/O.P.00/00/0000
^ Permit Voided Parcel Id # 1212680000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
I have read and understand~he afore mentione mfor
Signature ~~~~~,~~~ ~~~
_. - _ _ Dat~ ,- .,
Address PO BOX 825 OSHKOSH WI 54903 - 0825 Telephone Number (920) 231-5025
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
Plumbing Contractor WELLNITZ PLUMBING
PROJECT LOCATION
Buildin Address / / Subdivision Name
~ ~ ~ /~ /t/~C'~J''~ ~(C' Lot No.
Zoning District Setbacks: Front Left,~r ,~, Right ~
Rear ~.
'J
ft.
,2 ,r Q ft. ._ ~ ft. ~~~,~' ft.
PROJECT INFORMATION
CCUPANCY
Single Family AREA
Unfnushed Basement U~ sq.ft. CONST. TYPE
Site Const
t
d STORIES NUMBER OF
^ Two Family
^ Other
~
Living Area /
~f~~~
ft ruc
e
^ Manufactured
l~_Sto
D' ROOMS
Bathrooms
~
sq.
. ^ 2-Story
Garage.. ~~ ;~
sq
ft OUNDATION ^ Bi-level ,~ Bedrooms
USE
^ Seasonal
~ .
.
HEIGHT
Concrete
^ Masonry
^ Tri-level
^ Quad-level
2 Remaining
ermanent
^ Other
Height of the Structure (from fmal grade to the peak
^ Treated Wood ^ Other Finished Rooms
of the roof) /'' ~~ ~ ^ Other
ELECTRICAL
Panel Size: PLUMBING
Sewer WATER BUILDING COST
00 Amps ~B~Munici al
p
Municipal Utility Sale Price of the Project $ y~G"j, ~,.~
^ 200 Amps ^ 3 tic
^ Private On-Site Well (Final cost of house, lot & labor)
Service:
Permit No.
MI1~.TS -
^ Underground
' The Cost of the Lot $ 2d ~~
.e
bverhead --~
MINiJS -
HEAT LOSS ~ The Cost of the Mechanicals $ ~.~e's~l/
Envelope Btt~/Iir EQUALS =
The Cost of Construction $ ~Q'~
Infiltration Btu/Hr _ (Fair market value which includes labor)
ENERGY SOURCE '
HVAC EQUIPMENT '~
~orced Air Furnace
Choices: Natural Gas, L.P., Oil, Elec, Solid, Solar ^ Radiant Baseboa_ rd or Panel
Space Htg ^ Heat Pump ~ ~~ 31 2008
^ B
il
o
er
Water Htg ^ Central Air Conditioning
^ Other -
APPLICANTS SIGNATURE:
DATE:
CITY OF OSHKOSH BUILDING PERMIT APPLICATION
Wisconsin Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0133809
P.O. Box 2509
Madison, WI 53701-2509 APPLICATION Parcel No.
Wisconsin Statues 101.63, 101.73
^ Constr ^HVAC ^ Elec ^ Plbg ~ Erosion ^ Other:
Owner's Name Mailing Address Telephone No.
HRS DEVELOPMENT INC PO BOX 825 OSHKOSH WI 54903 - 0825
Contractor: / Con Elec HVAC Plbg Lic/Cert # Mailing Address Telephone No.
SALZER SIDING 7351 PO BOX 825 OSHKOSH WI 54903 _ 825 (920) 231-5025
Dwelling Contr. Qualifier LiGCert # The Dwelling Contr. Qualifier shall be an owner, CEO, COB or employee of
Harold R Salzer 7352 Dwelling Contr.
Contractor: ^ Con ^/ Elec ^ HVAC^ Plbg Lic/Cert # Mailing Address Telephone No.
SECKAR ELECTRIC CO INC 689404 5920 COURTNEY PLUMMER RD WINNECONNE WI 54986 - 9728 (920) 582-4909
Contractor: Con Elec / HVAC Plbg Lic/Cert # Mailing Address Telephone No.
SOLAR HEATING SERVICES LLC 1013252 9591 MEADOW BROOK RD BERLIN WI 54923 _ 9230 920-361-0792
Contractor: Con Elec HVAC / Plbg LiGCert # Mailing Address Telephone No.
WELLNITZ PLUMBING 223819M 4810 AMBERWOOD LN APPLETON WI 54913 - 7924 (0)231-7390
Lot Area S . ft. 1/4, "1%4,Section ,T N,R E(or)W
Building Address Subdivision Name iot No. Block No.
1902 ROOSEVELT AVE
Zoning District(s) Zoning Permit No. Front Rear Left Right
l
...,
/ New ^ Repair / Single Family Entrance Panel / Forced Air Furnace Nat L.P. Oil Elea Solid Sola
^ Alteration Two Family
^ Raze Size: 100 am ^ Radiant Baseboard or Panel Fuel Gas
^ Addition
^ Move Garage Service: ^ Heat Pump Space Htg ^/ ^ ^ ^ ^ ^
^ Other (print): ^/ Overhead
^ Boiler
Water Htg
^/
^ ^ ^ ^ ^
^ Underground
Other:
^
'
~ ^ Central Air Conditioning Dwelling unit will have 3 kilowatt or
TYKE`
^/ Site Constructed /' ,OIf~DA
Concrete '~ Other
more installed electric space heating equip.
Unfinished Manufactured
^ ^ Masonry ~ Infiltration control option is: ^/ Full sealing
~
^ Treated Wood Sewer of joints. ^ Blower door test ^ Exterior
Basement 1306 S . ft.
q ~'
^ Oth ^/ Municipal air infiltration barrier.
Li
i / 1-Sto
r er
v
ng Area 1306 Sq. ft. Y ^ Septic
2-Sto
^ ry 8_a~$E
P
it N
23565
l
E
Garage 576 Sq, ft, ^ Seasonal erm
o. nve
ope
BTU/HR
^ Other g~;fyyrA', Infiltration 15985 BTU/HR
^/ Permanent „
^/ Municipal Utility NG~ "
^/ Plus Basement ^ Other ^ Private On-Site Well 100000
I agree to comply with all applicable codes, statutes and ordinances and with the conditions of this permit; understand that the issuance of the permit creates no legal liability,
express or implied, on the state or municipality; and certify that all the above information is accurate. If one acre or more soil will be disturbeb, I understand that this
project is subject to ch.NR 151 regarding additional erosion control and stormwater management. I expressly grant the building inspector, or the inspector's authorized agent,
permission to enter the premises for which this permit is sought at all reasonable hours and for any proper purpose to inspect the work which is being done.
^ J I vouch that I am or will be an owneroccupant of this dwellin
for which I a
l
i
f
g
m app
y
ng
or an erosion control or construction permit without a Dwelling
Contractor Certification and have read the cautionary, statment re ardin ntra r po bility the Building Permit Application.
_
APPLICANT'S SIGNATURE l~ DATE SIGNED ~/ -~~
APPROVAL CONDITIONS This permit is issued p su the foil con 'ions. Failure to comply may result in suspension or
revocation of this permit or other penal
Submit truss plans prior to installation. Maintain erosion control until lawn is established.
^ Town ^ Village ^/ City ^ County ^ State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
Plan Review $75.00 `~ Construction
Inspection ^HVAC Name Allyn Dannhoff
^ Electrical
Wis. Permit Seal $30.00 ^ plumbing Date 11/4/2008
Other ^/ Erosion
Total $105.00 ^ 381694 Cert. No. 70264
SBD-5823 (R. 07/491
0
50'
~ 23.0
0 3.0
N 24X24 SLAB DRIVEWAY AND
PARKING OR GRAVEL ACCESS DRIVE
GARAGE 24' MAX CAD LOT LINE
o w
(V
~
`1 U
Z
J W
W
p ~
w
~ J
Lf
M
)
(n ~
0 15.0
~ PATIO
o
n ~i
0
~ci
HOUSE o.
I PLAN # °'
RAN-1306-1008 _
SILT FENCE
2'X6' LANDING
INTO SIDE SET BACK
0 0 ~o
co
~ ~
0
2.0
0
N
26.0
0 7.5 28.0 14.5
Sri
N
50.0
ROOSEVELT
in
o'
w
Z_
UII'.
RE ~
FOR CO C
WISCONSIN a
R IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE PROPER
EROSION CONTROL BY USE OF SILT FENCING, GRAVEL ACCESS STOCKPILED SOIL MUST BE SEEDED WITH RYE GRASS OR COVERED
ROADWAY OR OTHER APPROVED METHOD BY LOCAL AUTHORf1Y. WITH A TARP. EROSION CONTROL SHALL BE PLACED AT DOWN SLOPE
CONSULT LLH.R. 21.125, I.LH.R 21.13. AND LOCAL BUILDING OF THE STOCKPILE.
INSPECTOR FOR ANY QUESTIONS.
Pei sdaress 1906 ROOSEVELT ROSS DESIGN LLC
scale. 1'20' Coatrnctor HARRY SALZER
Date 10-30-08 TEI. (820) 426-1921 E-Mail irdesignmyahoo.com
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address /lc>Z ~c:~~~ ~'/ ~ Permit # /J~ Jam' ~O~
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also required
to have window well areas in accordance with COMM 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with COMM
21.08. The door and frame assembly between the dwelling unit and an attached garage
shall be labeled by an independent testing agency as having a minimum fire-resistive
rating of 20 minutes. All drywall joints are required to be taped/sealed unless the
joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and
backed by solid wood or drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, slits and holes in electrical boxes, gaps
around heating ducts, and holes in the return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected with battery back-up.
5. Hydromassage tubs are required to have an access panel to the motor. The access panel
must be accessible without removing the finish of the house.
6. The truss manufacturer must design all overframing, according to standards set by the
truss plate institute, or structural calculations must be provided prior to the rough building
inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them. -
9. Column caps are to be designed to ensure adequate beam bearing, provide a positive
connection to the beam without splitting the member, and provide lateral restraint.
I:\Inspections\Forms\Printed Forms\Standard Conditions~of Approval Rev 11-06.doc
10. The property owner and applicant is responsible for compliance with COMM 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from. the street at the end of each workday.. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due
to the electrical inspector needing to look at the power serving the appliances;
16. A 6' stepladder must be on site at the final inspection to provide access to the attic.
17. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. At the final inspection no furniture or personal
belongings are allowed in the dwelling. If occupancy is required prior to the completion
of the house the applicant/owner is required to submit an application for a Temporary
Occupancy Permit along with the required fees. A Temporary Occupancy maybe
approved provided that all health and safety issues are complete and approved.
18. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
19. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
Signature of Applicant~~ ;~ ~-~ ~ ~ Date . ~~~-c~J-'~
I:\Inspections\Forms\Printed Forms\Standard Conditions of Approval Rev 11-06.doc