Loading...
HomeMy WebLinkAbout0133809-BuildingCITY OF OSHKOSH No 133809 OSHKOSH ON THE WATER Job Address 1902 ROOSEVELT AVE BUILDING PERMIT -APPLICATION AND RECORD Designer Category 110 -New Single Family Owner HRS DEVELOPMENT INC Contractor SALZER SIDING Create Date 11/04/2008 Plan 038-1108 Type ~ Building ~ Sign ~ Canopy ~ Fence ~ Raze Zoning R1 Class of Const: 8 Size irreg Unfinished/Basement 1306 Sq. Ft. Rooms 3 Height 16 Ft. ^ Projection Finished/Living 1306 Sq. Ft. Bedrooms 3 Stories 1 Canopies Garage 576 Sq. Ft. Baths 2 Signs Foundation ~ Poured Concrete ~ Floating Slab ~ Pier ~ Other 0 Concrete Block ~ Post ~ Treated Wood Occupancy Permit Required Occupancy Fee $0.00 Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 1 # Structures 1 Use/Nature of Work New Single Family Residence with Detached Garage /One Story House, 1306 sf, 3 bed, 2 bath, 576 sf Detached Garage, 14x15 patio. HVAC Contractor SOLAR HEATING SERVICES LLC Electric Contractor SECKAR ELECTRIC CO INC Fees: Valuation $85,000.00 Plan Approval issued By: $75.00 Permit Fee Paid $373.00 Park Dedication $0.00 Date 11/05/2008 Final/O.P.00/00/0000 ^ Permit Voided Parcel Id # 1212680000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. I have read and understand~he afore mentione mfor Signature ~~~~~,~~~ ~~~ _. - _ _ Dat~ ,- ., Address PO BOX 825 OSHKOSH WI 54903 - 0825 Telephone Number (920) 231-5025 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Plumbing Contractor WELLNITZ PLUMBING PROJECT LOCATION Buildin Address / / Subdivision Name ~ ~ ~ /~ /t/~C'~J''~ ~(C' Lot No. Zoning District Setbacks: Front Left,~r ,~, Right ~ Rear ~. 'J ft. ,2 ,r Q ft. ._ ~ ft. ~~~,~' ft. PROJECT INFORMATION CCUPANCY Single Family AREA Unfnushed Basement U~ sq.ft. CONST. TYPE Site Const t d STORIES NUMBER OF ^ Two Family ^ Other ~ Living Area / ~f~~~ ft ruc e ^ Manufactured l~_Sto D' ROOMS Bathrooms ~ sq. . ^ 2-Story Garage.. ~~ ;~ sq ft OUNDATION ^ Bi-level ,~ Bedrooms USE ^ Seasonal ~ . . HEIGHT Concrete ^ Masonry ^ Tri-level ^ Quad-level 2 Remaining ermanent ^ Other Height of the Structure (from fmal grade to the peak ^ Treated Wood ^ Other Finished Rooms of the roof) /'' ~~ ~ ^ Other ELECTRICAL Panel Size: PLUMBING Sewer WATER BUILDING COST 00 Amps ~B~Munici al p Municipal Utility Sale Price of the Project $ y~G"j, ~,.~ ^ 200 Amps ^ 3 tic ^ Private On-Site Well (Final cost of house, lot & labor) Service: Permit No. MI1~.TS - ^ Underground ' The Cost of the Lot $ 2d ~~ .e bverhead --~ MINiJS - HEAT LOSS ~ The Cost of the Mechanicals $ ~.~e's~l/ Envelope Btt~/Iir EQUALS = The Cost of Construction $ ~Q'~ Infiltration Btu/Hr _ (Fair market value which includes labor) ENERGY SOURCE ' HVAC EQUIPMENT '~ ~orced Air Furnace Choices: Natural Gas, L.P., Oil, Elec, Solid, Solar ^ Radiant Baseboa_ rd or Panel Space Htg ^ Heat Pump ~ ~~ 31 2008 ^ B il o er Water Htg ^ Central Air Conditioning ^ Other - APPLICANTS SIGNATURE: DATE: CITY OF OSHKOSH BUILDING PERMIT APPLICATION Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0133809 P.O. Box 2509 Madison, WI 53701-2509 APPLICATION Parcel No. Wisconsin Statues 101.63, 101.73 ^ Constr ^HVAC ^ Elec ^ Plbg ~ Erosion ^ Other: Owner's Name Mailing Address Telephone No. HRS DEVELOPMENT INC PO BOX 825 OSHKOSH WI 54903 - 0825 Contractor: / Con Elec HVAC Plbg Lic/Cert # Mailing Address Telephone No. SALZER SIDING 7351 PO BOX 825 OSHKOSH WI 54903 _ 825 (920) 231-5025 Dwelling Contr. Qualifier LiGCert # The Dwelling Contr. Qualifier shall be an owner, CEO, COB or employee of Harold R Salzer 7352 Dwelling Contr. Contractor: ^ Con ^/ Elec ^ HVAC^ Plbg Lic/Cert # Mailing Address Telephone No. SECKAR ELECTRIC CO INC 689404 5920 COURTNEY PLUMMER RD WINNECONNE WI 54986 - 9728 (920) 582-4909 Contractor: Con Elec / HVAC Plbg Lic/Cert # Mailing Address Telephone No. SOLAR HEATING SERVICES LLC 1013252 9591 MEADOW BROOK RD BERLIN WI 54923 _ 9230 920-361-0792 Contractor: Con Elec HVAC / Plbg LiGCert # Mailing Address Telephone No. WELLNITZ PLUMBING 223819M 4810 AMBERWOOD LN APPLETON WI 54913 - 7924 (0)231-7390 Lot Area S . ft. 1/4, "1%4,Section ,T N,R E(or)W Building Address Subdivision Name iot No. Block No. 1902 ROOSEVELT AVE Zoning District(s) Zoning Permit No. Front Rear Left Right l ..., / New ^ Repair / Single Family Entrance Panel / Forced Air Furnace Nat L.P. Oil Elea Solid Sola ^ Alteration Two Family ^ Raze Size: 100 am ^ Radiant Baseboard or Panel Fuel Gas ^ Addition ^ Move Garage Service: ^ Heat Pump Space Htg ^/ ^ ^ ^ ^ ^ ^ Other (print): ^/ Overhead ^ Boiler Water Htg ^/ ^ ^ ^ ^ ^ ^ Underground Other: ^ ' ~ ^ Central Air Conditioning Dwelling unit will have 3 kilowatt or TYKE` ^/ Site Constructed /' ,OIf~DA Concrete '~ Other more installed electric space heating equip. Unfinished Manufactured ^ ^ Masonry ~ Infiltration control option is: ^/ Full sealing ~ ^ Treated Wood Sewer of joints. ^ Blower door test ^ Exterior Basement 1306 S . ft. q ~' ^ Oth ^/ Municipal air infiltration barrier. Li i / 1-Sto r er v ng Area 1306 Sq. ft. Y ^ Septic 2-Sto ^ ry 8_a~$E P it N 23565 l E Garage 576 Sq, ft, ^ Seasonal erm o. nve ope BTU/HR ^ Other g~;fyyrA', Infiltration 15985 BTU/HR ^/ Permanent „ ^/ Municipal Utility NG~ " ^/ Plus Basement ^ Other ^ Private On-Site Well 100000 I agree to comply with all applicable codes, statutes and ordinances and with the conditions of this permit; understand that the issuance of the permit creates no legal liability, express or implied, on the state or municipality; and certify that all the above information is accurate. If one acre or more soil will be disturbeb, I understand that this project is subject to ch.NR 151 regarding additional erosion control and stormwater management. I expressly grant the building inspector, or the inspector's authorized agent, permission to enter the premises for which this permit is sought at all reasonable hours and for any proper purpose to inspect the work which is being done. ^ J I vouch that I am or will be an owneroccupant of this dwellin for which I a l i f g m app y ng or an erosion control or construction permit without a Dwelling Contractor Certification and have read the cautionary, statment re ardin ntra r po bility the Building Permit Application. _ APPLICANT'S SIGNATURE l~ DATE SIGNED ~/ -~~ APPROVAL CONDITIONS This permit is issued p su the foil con 'ions. Failure to comply may result in suspension or revocation of this permit or other penal Submit truss plans prior to installation. Maintain erosion control until lawn is established. ^ Town ^ Village ^/ City ^ County ^ State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 `~ Construction Inspection ^HVAC Name Allyn Dannhoff ^ Electrical Wis. Permit Seal $30.00 ^ plumbing Date 11/4/2008 Other ^/ Erosion Total $105.00 ^ 381694 Cert. No. 70264 SBD-5823 (R. 07/491 0 50' ~ 23.0 0 3.0 N 24X24 SLAB DRIVEWAY AND PARKING OR GRAVEL ACCESS DRIVE GARAGE 24' MAX CAD LOT LINE o w (V ~ `1 U Z J W W p ~ w ~ J Lf M ) (n ~ 0 15.0 ~ PATIO o n ~i 0 ~ci HOUSE o. I PLAN # °' RAN-1306-1008 _ SILT FENCE 2'X6' LANDING INTO SIDE SET BACK 0 0 ~o co ~ ~ 0 2.0 0 N 26.0 0 7.5 28.0 14.5 Sri N 50.0 ROOSEVELT in o' w Z_ UII'. RE ~ FOR CO C WISCONSIN a R IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE PROPER EROSION CONTROL BY USE OF SILT FENCING, GRAVEL ACCESS STOCKPILED SOIL MUST BE SEEDED WITH RYE GRASS OR COVERED ROADWAY OR OTHER APPROVED METHOD BY LOCAL AUTHORf1Y. WITH A TARP. EROSION CONTROL SHALL BE PLACED AT DOWN SLOPE CONSULT LLH.R. 21.125, I.LH.R 21.13. AND LOCAL BUILDING OF THE STOCKPILE. INSPECTOR FOR ANY QUESTIONS. Pei sdaress 1906 ROOSEVELT ROSS DESIGN LLC scale. 1'20' Coatrnctor HARRY SALZER Date 10-30-08 TEI. (820) 426-1921 E-Mail irdesignmyahoo.com CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address /lc>Z ~c:~~~ ~'/ ~ Permit # /J~ Jam' ~O~ Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with COMM 21.03. 2. Garage spaces shall be separated from the dwelling unit in accordance with COMM 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire-resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, slits and holes in electrical boxes, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected with battery back-up. 5. Hydromassage tubs are required to have an access panel to the motor. The access panel must be accessible without removing the finish of the house. 6. The truss manufacturer must design all overframing, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. - 9. Column caps are to be designed to ensure adequate beam bearing, provide a positive connection to the beam without splitting the member, and provide lateral restraint. I:\Inspections\Forms\Printed Forms\Standard Conditions~of Approval Rev 11-06.doc 10. The property owner and applicant is responsible for compliance with COMM 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from. the street at the end of each workday.. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances; 16. A 6' stepladder must be on site at the final inspection to provide access to the attic. 17. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. At the final inspection no furniture or personal belongings are allowed in the dwelling. If occupancy is required prior to the completion of the house the applicant/owner is required to submit an application for a Temporary Occupancy Permit along with the required fees. A Temporary Occupancy maybe approved provided that all health and safety issues are complete and approved. 18. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 19. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. Signature of Applicant~~ ;~ ~-~ ~ ~ Date . ~~~-c~J-'~ I:\Inspections\Forms\Printed Forms\Standard Conditions of Approval Rev 11-06.doc