HomeMy WebLinkAbout0084503-Plumbing (interior)OSHKOSH
ON THE WATER
Job Address 505 GOLDEN IRIS DR
CITY OF OSHKOSH
PLUMBING PERMIT -APPLICATION AND RECORD
Owner DEWEY HOMES
Contractor P&S PLUMBING
Category 410 -Residential-Interior
No 84503
Create Date 12/06/2000
Plan
Bathtub 2 Shower
Whirlpool Floor Drain
Lavatory 2 Lndry Tray
Toilet 2 Lndry Stndp
Res. Sink 1 Disposal
Bar Sink Dishwasher
Water Heater 1 Sump Pump
Site Drain Classrm Sink
Roof Drain Breakrm Sink
Use/Nature
of Work
_ Ejector/Grind Dip Well F Prep Sink Gar Drain
1 Water Softner Drink Ftn Serv Sink Soda Disp
_ Local Waste Wait. St. Shamp Sink Coffee Maker
1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
1 Bidet Exam Sink Catch Basin Ext Grease Trap
1 Beer Tap Sculry Sink Wash Ftn
1 Dent. Oper. Hand Sink Urinal
_ Lab Sink Plaster Sink Standp Rec
_ Sterilizer Surgeons Sink Ice Maker
NSFR
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation $4,500.00
Issued By
Plan Approval $0.00 Perrnit Fees $78.00
Permit Voided
Date 03/02/2001
In the perfomtance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature /y~~•, /`'l,,J? ~~ ~ ~ ~ Date
3l2/c/
Agent/Owner
Address PO BOX 2153 APPLETON WI 54913 - 0000 Telephone Number 734-3912
Job Address 505 GOLDEN IRIS DR
Owner DEWEY HOMES
agory 410 -Residential-Interior
Bathtub ~ l2 Shower
Whirlpool Floor Drain
Lavatory ~ Lndry Tray
Toilet / f' 2 Lndry Stndp
Res. Sink ~ Disposal
Bar Sink Dishwasher
Water Heater _ ~ 1 Sump Pump
Site Drain Classrm Sink
Roof Drain Breakrm Sink
Use/Nature
of Work
Plumbing Permit Work Card
Permit Number 84503
Contractor P&S PLUMBING
Plan
Ejector/Grind Dip Well
_~ Water Softner ~ Drink Ftn
Local Waste Wait. St.
/ 1 Clothes Wshr Ice Chest
Bidet Exam Sink
Beer Tap Sculry Sink
~ 1 Dent. Oper. Hand Sink
Lab Sink Plaster Sink
Sterilizer Surgeons Sink
F Prep Sink
Serv Sink
Shamp Sink
FINV11st Sink
Catch Basin
Wash Ftn
Urinal
Standp Rec
Ice Maker
Create Date 12/06/2000
Value $4,500.00
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
NSFR
Sanitary Sewer
Size Material Type
(~ , ~, ~~~
storm sewer ~~ ~y,.~ ~~ '~~
Inspector
# Conn.Type
~- ~,V,~~DaP~ls o~
~`"'"'
~ ~ s/~~
~~~oved
3~y 0.,.;.t.~ Wks
Date 00/00/0000 Type
WATER CALCULATION WORKSHEET FOR S o5'- G- ac D tr.t,. / R r S
NAME OF PROJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE
1. Demand of building in building in gallons per'minute. WSFU's ~ o (GPM) l `~
2. Difference in elevation fram main or-external pressure tank to building control valve. (feet) ~ i
3. Size of water meter (when meter is required) 5/8" _, 3/4" /, 1" _, 1-1/2" _, 2" _, larger size
4. Developed length from main or external pressure tank to_building control valve. (feet) 5 G r
5. Low pressure at main in street or external pressure tank. (psi} ~/ ~/
GALGULATE WATER SERVICE PRESSURE LOSS
6. Low pressure at main in street or external pressure tank. (value of # 5 above) `~ `/
7. Determine pressure loss due to friction in 1 inch diameter
water service. Subtract value of "7"
(Water service piping material is ~' r " cap!' cat t )
subtotal t ! o
8. Determine pressure loss due to elevation,
(multiply the value of # 2 above by .434) Subtract value of "8" . `/'1
9. Available pressure after the bldg. control valve. (enter in "B" below) subtotal '~ 6 , S 3
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A")
B. Available pressure after the bldg. control valve. (from "9" above)
C. Pressure loss of water meter (when meter is required)
D. Pressure at controlling fixture.
(Controlling fixture is LL. c. )
E. Difference in elevation between the building control valve
and the controlling fixture in feet Fl X .434 psi/ft.
F. Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture.
(Pressure loss due to ~
G. Developed length from building control valve to controlling
fixture in feet ~ G X 1.5
(Water distribution piping material is _ r' M r~ c OPP[~i1 )
A. Pressure available for uniform loss
SBD -6479 (R11/98)
Value of "B" 3 ~ . S 3
Subtract value of "C" ~ , 5"~
subtotal 3 3 , 0 3
Subtract value of "D" b~
subtotal ~ S . ~ 3
Subtract value of "E" 3 - `/'7
subtotal z r,s~
Subtract value of "F" -~ -
subtotal Z l ~ S ~
Divide by value of "G" ~
subtotal , 2 3 9 5
Multiply by 100
«A„ = 3, 9 ~
TAt~cis fs?~~~a- C
l' ~ ~ cv
r
WATER DISTRIBUTION DATASHEET
Date: March 5, 2001
Name: P & S PLUMBING Project: NSFR
Street:
City:
Street: 505 GOLDEN IRIS DR
City:
1. 12.8 Gallon per minute buiding demand, predominatly Flush Tank.
2. 44.0 Low pressure at the Main in the Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter.
4a. 1.0 Lb loss from a 15.0 ft 1 " Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop.
Pressure loss detemined using a C value of 130 ,inside diameter of .995 and a velocity of 5.3 ft per sec.
4b. 3.2 Lb loss from a 50.0 ft 1" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 130 ,inside diameter of .995 and a velocity of 5.3 ft per sec.
5. 2.5 Lb loss from a 3/4in Meter
6. 37.4 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A - B- C+D+E x 100
F
A. 29 Pressure available for uniform loss (psi/100 feet of pipe).
B. 37.4 Lbs of pressure available at the Water Meter.
C. 8.0 Pressure needed at the controlling fixture. T/S FAUCET
D. 3.5 Lb loss resulting from a 8_0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a serving the controlling fixture.
F. 90.0 Ft Developed length from the 60.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 g g
Maximum Gpm 6.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 8 0 17.5 34 60 110 270 480 776 1833
Fixture Listing
Date: March 5, 2001
Name: P & S PLUMBING
Street:
City:
Non Public Use Fixtures
Hot Cold Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00
Total Water Supply Fixture Unit:;
12.8 Gallon per minute demand of the building. Predominatly Flush Tank
28.8 Pressure available for uniform loss. For the table use - 29.0
7.00 15.00 18.00
Maximuu Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 8 0 17.5 34 60 110 270 480 776 1833
Project: NSFR
Street: 505 GOLDEN IRIS DR
City:
WATER CALCULATION WORKSHEET FOR S'~ G ~ G- G`!~ Us.t,~ l JZ t S r! 2 ~ yiS ~~~
NAME OF PROJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE' S12E
1. Demand of building in building in gallons per minute. WSFU's ~~ _ (GPM)
2. Difference in elevation from main. or external pressure tank to-building control valve. {feet) •~' J
3. Size of water meter (when meter is required) 5/8" ~, 3/4" 1~1" _, 1-1/2" _, 2" _, larger size
4. Developed length from main ar external pressure tank to building-control valve. (feet} 5-G t
5. Low pressure at,main in street or-l~xtemal pressure tank..,..... (psi) ~/ `/
CALCULATE WATER SERVICE PRESSURE LOSS
6. Low pressure at main in street or external pressure tank. (value of # 5 above) L/ ~~
7. Determine pressure loss due to friction in ~_inch diameter
water service. Subtract value of "7" ~~ 5~
(Water service piping material is 1f I ~''' c c ~®c~Y1 )
subtotal ~l ~. ~
8. Determine pressure loss due to elevation,
(multiply the value of # 2 above by .434) Subtract value of "8" ~ ~ ~/ ~
9. Available pressure after the bldg. control valve. (enter in "B" below) subtotal 3 `7 , 0 3
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A")
B. Available pressure after the bldg. control valve. (from "9" above) Value of "B" 3 ~ ~ d 3
C. Pressure loss of water meter (when meter is required) Subtract value of "C" -3
subtotal ~ ~ d
D. Pressure at controlling fixture. Subtract value of "D" ~
(Controlling fixture is _ cc1 ~ C_ )
subtotal 2 ~ . ~ 3
E. Difference in elevation between the building control valve
and the controlling fixture in feet _~_ X .434 psi/ft. Subtract value of "E" 3 ~ ~/ `~
subtotal 2 Z , S~
F. Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture. Subtract value of "F" / S.-
(Pressure loss due to w~~za-n ~`~~ r~-~a~~a )
subtotal ''~. 5~
G. Developed length from building control valve to controlling
fixture in feet ~/ ~ X 1.5 Divide by value of "G" ~ Z
(Water distribution piping material is ~ ~ i'7 " c c,°~c3/! ) subtotal , / G ~ U
Multiply by 100
A. Pressure available for uniform loss "A" _ ! ~~ Sa
SBD -6479 (R11/98)
<<
~=. ~r .
3 ~<
~~ - ~ 3 ~ ~
w. s , ~, ti.