HomeMy WebLinkAboutBuilding E6-2511-0908 (10/7/08)ON THE WATER
October 7, 2008
Stanley Bye
Stanley Bye -Architect
950 Gail Ave
Neenah, WI 54956
David Viaene
W 10460 Givens Road
Hortonville, WI 54944
Site:
Christopher Allen's
1226 Oshkosh Ave
Oshkosh WI 54902
Plan Number: E6-2511-0908
For:
Description: Addition /Alteration
Object Type: Building Only Leve12 Alteration
Class of Construction: VB, 963 sq ft ; Unsprinklered
Maximum No of Occupants: 99
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Note: This review is limited to the scope of the plans provided. Any alterations to the 2°d floor will require additional plans
to be submitted for review. All safety related code issues will need to be addressed on the 2°a floor even if the space
is unoccupied. Additionally no storage is permitted on the 2°d floor without further review.
Key Item(s) /Conditions:
• Comm 61.03 (13) EXISTING BUILDINGS AND STRUCTURES. (a) Unless otherwise
specifically stated in this code, an existing building or structure, and every element, system, or
component of an existing building or structure shall be maintained to conform with the building code
provisions that applied when the building, structure, element, system, or component was constructed,
or altered except when required by subsequent editions of the building code.
• IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
• IBC 1003.2.2.5 Posting of occupant load. Every room or space that is an assembly occupancy shall have
the occupant load of the room or space posted in a conspicuous place, near the main exit access doorway
from the room or space. Posted signs shall meet the requirement of municipal code section 13-5. Min 12
inches in length, min 4 inches in height with min % inch lettering and the numbers being minimum 3
inches in height. The sign shall state "Limit (number) Persons".
• IBC 1011 Exit signs are required to be installed per this section
I:`•.lnsnrcl~irs.Pl,an Recirv:'.C't~nimeeria) ('I;~~ Rrvew^_~ii5'~:F.G-2511-i;~ii;$ 12^_li(i.<hkvsl~ ~re131d~..tloc
Page 1 of 2
• IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are
required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4.
Existing means of egress emergency lighting is permitted to be maintained in compliance with the code
in effect at the time of construction. Any altered path of egress, or new path of egress, and any new
emergency lighting being installed is required to comply with current code requirements.
• Comm 61.30(3) This review does not include Truss components. Submit, prior to installation one set
of properly signed and sealed truss plans, and completed SBD-118 application form with appropriate fees.
• Comm 61.30(3) This plan review does not include heating, ventilation, or air conditioning. HVAC
plans are required to be submitted and approved prior to installation or modification of HVAC system.
• Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by;the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
SUBMIT:
• Comm 61.40 (4) Supervision. Prior to the initial occupancy of a new building or addition and prior to the
final occupancy of an alteration of an existing building the supervising professional shall file a compliance
statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence maybe made to me at the number listed below or the address on this letterhead.
Respectfull ,
rian e
Building Systems Consultant
(920) 236-5051 Monday -Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci. Oshkosh. wi.us
cc: Property file
Fee Required $ 320.00
Fee Received $ 320.00
Balance Due $ 0.00