HomeMy WebLinkAbout2008-Buidling~~IV..(J I-l
ON THE WATER
October 22, 2008
Tom Mudrovich
Mudrovich Architects
300 N 31d Street, Suite 304
Wausau, WI 54403
Mark Craig
Compass Properties
300 N 3`d Street Suite 214
Wausau, WI 54403
Site: Plan Number: E6-2512-0908-R
American Red Cross
515 S Washburn St. Suite 201
Oshkosh WI 54904
For:
Description: REVISION -Corridor ceiling
Object Type: Building only for suite 201 and 203A
Class of Construction: IIB - 5340 Sq Ft.; Unsprinklered
Occupancy: B: Business /Office
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) !Conditions:
• The installation of the ceiling assembly NER-258 is required to have the gypsum backing installed where
the liner panels are not in tight contact with the J-runner, as shown in the detail provided by USG for this
condition. A copy of this detail is attached to this letter.
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
• All prior conditions that were included in the September 25th plan review letter are still required to
be complied with.
I:lTnn..<t~ ~rs;Pi,~n iZC~'il'~'~.~~I1171R'C.?'~lilj P;at) ~C~'Ct;' ^n~~~1~:(1-Z>1?-f}~/pSlt ~~ J ~ ~~ ~i~tl?t1iiS 5t t31~ig ttevision OnFr.doi
Page 1 of 2
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence maybe made to me at the number listed below or the address on this letterhead.
Respec
Brian oe
Building Systems Consultant
(920) 236-5051 Monday -Friday 7:30 A.M
bnoe@ci.oshkosh.wi.us
cc: Property file
to 8:30 A.M and 12:30 A.M to 1:30 P.M.
Fee Required $
Fee Received $
Balance Due $
100.00
100.00
0.00
1~~~.b~.1t;.~I~onsiPkan 17e~•ietir?C`nmr:~e~ci,Ff flan 12e~~ew RO?,'•:56-2513-d908iZ ,515 S ~~"ai~bim~ 5? i3icg lte~~ision €~r(~.doc
Page 2 of 2
Shaft Wall -Wall Intersactlan 7hisuscsystemDelaifmustnohbeosed
without a complete avaloation'by amens design
Design No. U4~ 5 System B or U438 [J-Runner Gap] ~ P ~''~b'l~°`~'~"~~'
1/2"max. SNEETROCK BRAND ACOUSTICAL SEALANT
5/8" SHEETROCK BRANDFIRECQDE CORE, ,,_
d. ~ GYPSUM PANELS
~ --
,_,.._ .
~: ___. -
i _
a USG STEEL J-RUNNER
CONCRETE a ~ FASTENERS. AS REQUIRED
- WALt - _..w. ,
:,
_ .
. ~~-~- STRIPS OF EITHER
d 5/8~' SWEETROCK BRAND FIRECODE GYPSUMPANELS OR
x`.
LtN~ ~ .:-----~
~ 'jihl~-;~ [~~
~ ~ Sz-*~~..~,
",
1" SHEETROCK BRAND' GYPSUfvI`L1NER PANELS
.. .. F.. ~ ,-~
>.
.-- ~-.-
' i-
- ~~
1" SHEETROCK BRAND GYPSUM
LINER PANELS
G USGCorporaUon DraWnby:
S50 West Atlams SVaet Approved: JME
ChlCago, IL 6066136J6 Date: x-25-2008
.4rchllecturalandTecl~rdpiSoluHons Sclle NTS
800-874.4968 Flie: