HomeMy WebLinkAboutBldg & HVAC F1-131-1086BCITY HALL 2'S Church Avenue " P O. Bcx 1130 Oshkosh. Wisconsin 54902-1130 City of Oshkosh Q~KQfH Nov. 18, 1986 ON THE WATER James E. Larson, Architect 600 S. Main St. Oshkosh, WI 54901 ' Dear Mr. Larson: New restaurant building 180 J t. l Mike T wohig, owner File #F1-131-10868 Building, Heating & Ventilation plans have been reviewed by this office for compliance with important code requirements. The drawings are stamped "Construction may proceed." All items that ore required to be changed by this letter must be corrected before comm'eneing that part of the work. This approval is not a Building Permit. Necessary city permits must be secured before commencing work. You are hereby advised that the owner, as defined in Chapter 101.01(1) of the Wisconsin State Statutes, is responsible for all code requirements not specifically cited herein. Code requirements are set forth in Chapters 50 through 64 of the rules of the Department of Industry, Labor and Human Relations. The building will be inspected during construction and a final inspection will be made after completion to insure complete compliance with city and state codes. The architect, professional engineer, builder or owner shall keep at the building, as evidence of approval, one set of plans bearing the stamp of approval. ILHR 50.12 Roof truss plans must be submitted to this office and be approved prior to install- ' ation. An examination fee will be required. Plans . must be submitted with a completed SB-118 form from the building designer. ILHR 53.10, 1LHR 53.11, Lintels are to be provided in accordance to calculations. ILHR 54.07 Safe and continuous passageways at least 3'8" wide shall be provided at all exits. ILHR 54.001 Building capacity is 74 persons. ILHR 64.67 Exhaust hood duct shall be protected with insulating material to withstand a flue temperature of not less than 1000° F. An automatic suppression system in accordance to s ILHR 64.67(6) shall be provided. Nov. 18, 1986 Page Two James E. Lorson, Architect ILHR 54.06(2) Exit lights shall be provided over all exit doors except the principal entrance. Additional exit lights shall be provided as necessary to direct the occupants to the exit doors. ILHR 52.04(10) The international symbol for barrier-free environments shall be placed at all entrances indicoting the location of the nearest accessible entrance and accessible toilet facilities. ILHR 50.12(4) Heating and ventilation calculations shall be provided (including transmission and ventilation losses, and a summary of the total building heat loss expressed in Btu/hour. Sign approvals are not included. It appears sign setbacks do not comply unless a variance is granted by the Board of Zoning Appeals. Sincerely, EDWARD REIMER Chief Building Inspector EL R:mr cc: Mike T wohig