HomeMy WebLinkAbout14350-Building Maintenance (9/09/08)~1
OSHKOSH
ON THE WATER
Issue Date 9/g/2008
Address 45 W SOUTH PARK AvF
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
Compliance Date 10/9/2008
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance No
Address City
257 GREELEY ST BERLIN
Required for Occupancy Occupancy
Name
Sent to / Owner JOSEPH C/TAMMY BERTZYK
Introduction
Item # 1 Code NEC 300.15
Description
09/09/2008
Last
Updated
It
ollowing a complaint from Paula Hayford and receipt of an inspection report from K&H Schwanke LLC, it is necessary that
tis office be contacted to inspect the premises and corrections be made at the above address accordingly.
Compliance No Compliance Date ~nmai~nnR
em # 2 ~oae wl Comm 16.18 Compliance No Compliance Date 10/09/2008
Description fisted or labeled equipment shall be installed or used, or both, in accordance with any instructions included in the listing or labeling, provided
he instructions, listing or labeling do not conflict with this chapter.
09/09/2008 Devices to be wired according to manufacturer's direction. Reversed polarity issues to be corrected. Ceiling fans should not be on a lighting
immer if the manufacturer requires a fan rated dimmer.
Last
Updated
Item # 3 Code NEC 395.12(5) Compliance No Compliance Date 10/09/2008
Description oncealed knob-and-tube wiring shall not be used in the following: Hollow spaces of walls, ceilings, and attics where such spaces are
nsulated by loose, rolled, or foamed-in-place insulating material that envelops the conductors. Attic wiring.
09/09/2008
Last
Updated
Item # 4 Code NEC 406.3(B) Compliance No Compliance Data ~nmo»nnn
Description
09/09/2008
Last
Updated
Item # 5
eceptacles and cord connectors that have grounding contacts shall have those contacts effectively grounded. 3 prong receptacles require a
rounding conductor.
a.aae iwurv ~uut ~ i-3ti(A) Compliance No Compliance Date 10/09/2008
Description he exterior of every structure including fences shall be maintained by the owner in good repair. All exterior surfaces thereof be kept painted
r covered with exterior siding for purposes of preservation and appearance. All building foundations shall be maintained. Soffits, fascia or trim
09/09/2008 oose or missing.
Last
Updated
Item # 6 Code UDC 23 Compliance No Compliance Date 10/09/2008
Description Proper, consistent pitch required from appliance outlet to chimney inlet. Water heater flue.
09/09/2008
Last
Updated
State Zip Code
WI 54923 -1261
14350 Page 1 of 3
INSPECTION SERVICES DIVISION ROOM 205
i~- DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CORRECTION NOTICE
ON THE WATER
Issue Date 9/9/2008 Compliance Date 10/9/2008
Address 45 W SOUTH PARK AVE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance No
Name Address City
Sent to / Owner JOSEPH C/TAMMY BERTZYK 257 GREELEY ST BERLIN
Required for Occupancy Occupancy
Introduction
Item # 7
Description
09/09/2008
Last
Updated
Following a complaint from Paula Hayford and receipt of an inspection report from K&H Schwanke LLC, it is necessary that
his office be contacted to inspect the premises and corrections be made at the above address accordingly.
Code MUN CODE 16-33 Compliance No Compliance Date 10/09/2008
Baking plumbing fittings to be maintained/repaired.
State Zip Code
WI 54923 -1261
14350 Page 2 of 3
J
OSHKOSH
ON THE WATER
Issue Date 9/9/2008
Address 45 W SOUTH PARK AVE
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
Compliance Date 10/9/2008
Name Address
Sent to / Owner JOSEPH C/TAMMY BERTZYK 257 GREELEY ST
Introduction
Item # 8
Description
09/09/2008
Last
Updated
Summary
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance No
City State Zip Code
BERLIN WI 54923 -1261
Required for Occupancy Occupancy
=ollowing a complaint from Paula Hayford and receipt of an inspection report from K&H Schwanke LLC, it is necessary that
his office be contacted to inspect the premises and corrections be made at the above address accordingly.
code MUN CODE 16-34A(1) Compliance No Compliance Date 10/09/2008
very dwelling unit shall have heating facilities which are capable of safely and adequately heating all habitable rooms and bathrooms to a
emperature of at least 67 degrees F with an outside temperature of minus 15 degrees without forcingthe heating system. All habitable rooms
o be supplied with adequate heat sources. All heating shall be in operation to maintain this minimum during all occupied periods. Safety
ncem if the heat exchanger is cracked.
contact this office for an inspection and/or correct the above violations and request a re-inspection within the next 30
Office hours are Monday-Friday 7:30-8:30am and 12:30-1:30pm. If you have questions feel free to contact me at
!74.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 10/9/2008
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1:30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature
Signature
Date~~ ~~~~
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Bldg
Elec
HVAC
Plbg
Designer
/ Other OCCUPANT 45 W SOUTH PARK AVE
/ Inspector Andrew Prickett
OSHKOSH WI 54901 -
14350 Page 3 of 3
Inspected by: Adam Krause 236-5274 akrause@ci.oshkosh.wi.us
SEP-04-2008 THU 02 40 PM CHOICE BANK FAX N0, 9202301302 P. 02/03
Pa®e: i of 2
SUMMARY REPORT
Second Look inspection Services 8/19/2008
K&H Schwanke LLC Serving Wisconsin For Over 2x Years Established >zn 1987
Wtsoottsin's Most IE~cperienoed Inspection Company
1(800) 585-4708
Doc #: JK 20080819 HAYFORD Giant Name: Paula Hayford
Dwelling Address: 45 W. South Paris Ave. Inspector: ]ask Kallio
Qshkosh Wx
This Summary Report b designed bo assist you the client a5 an overview of the full report regarding Material Adverse Fact(s)
of the property inspected. A Material Adverse Fadts) Is a o~mponent that is not functioning M lls Intended manner, which
would constitute a safety, health or structural hazard. If there are not any Material Adverse Fads found at today's inspection,
the Summary Report t>efow will not have any loems ilsbecl. Thus, no Material Adverse Facts, or, defects per the Real Estate
Offer To Purchase were present. Read your report fully and carefulllr and pay particular attention oo comments and
remmmendat:lons regarding Marginal, Malntenanoe or Monlbr raged components, or r8pairs that are naommended. If
neglected, many of tf~ese iternS can or wid develop tn0o Adverse Mateftal Fads in the near future. Thus, any of the
components raged as Marginal, Malnbenanoe, or Monitor, and the recommended repairs should be underseood and
undertaken to prevent the present corlditbn from worsening h16o a Adverse Material Fad oondttlon.
F~rioF ~ nents
1205x. SoffltJFasda/Trlm ~ Urrsatb~f+sctory. Various pieces of seffib /fascia /trim were loose or missing
allowing weber penetratlan_ Repair /replace the applicab[a material.
1212x. Exterior Electrical ~ Uesatisfictoty. There la open air spliced wiring at tfra sxtattor. Have corrected
for ~Y by a qualHled eleediei4n.
1606x. ReceptaclPS / ughting Unsatisfactory. One or more of the electrical reoaptadas In 45A kitchen had
reveres polarity. To r+oduCe the risk of electrical chock, con~ectthe reverse
polarity. One or more of the electrical reoeptaehis were unwounded. To reduce
the risk of electrical shock, ground the receptacles. Recommend installing a
(SCI nceptade m reduce the rink of shock.
G era! j~ rio
1909x. Electrical / Celling Fans Unsatisfactory. One or mote of the electiiczl receptacles had reverse polarity. To
reduce the risk of electrical shock, aern9ct the reverse polarity.
One or more of the. fats era on dimmer switches. This is not reootnmended
becauso R can stress the fan motor and prematurely age the motor. Recommend
installed proper switch 6yatsm.
Plumbina„Sy.~QpL
2105x. Waste Water J Drain J 'Unsatisfactory. Improper materials or seals/connections were present. Have a
Vent Lines qualified plumber make necessary correct#ons to eliminate chance of sewer gab
errteting the structure.
Leakage was present on some of the fittings. Repair or replace the fittings.
2114x. Water Header Venting Unsatisfactory. The flue has an Improper angle for proper venting. Correct the
engia of tfie flue for proper venting for safety.
SECOND LOOK HOME INSPECTIONS SERVING WISCONSIN FOR OVER 21 YEARS!
SEP-04-2008 THU 02 40 PM CHOICE BANK FAX N0. 9202301302 P. 03/03
Page: 2 of 2
SUMMARY REPORT
Second look Inspection Services ~ 8/x.9/2008
K&H Schwanke I.LC Serving Wlsoonsln For Over 2~ Years Established In 1987
Wisconsin's Most E~cperlenced inspection Company
1(800) 5854708
H~tinq Pia t~SY~ms
2207. Heat Exchanger Unsatisfsctoryy. There Is a crack or multiple cracks Ih the heat exchang®r. Either
furnace replacement or heat exchanger repleeemeat [s neoeasary far safety.
Attic Systems
2510x. gectrical W!Nng Unsatisfactory. Knob and tube wirln~ was present Insulation was in contactor
covering the knob and tubin{l. provide proper clearance from I~ulation for
safety. Air spliced electrical eonnactlons ware noted in the attlc. F.nelase the
spiked connection In covered iuncdon 6axss for safety.
SECOND LOOK HOME INSPECTIONS SERVING WISOONSJN FOR OVER 21 YE4RS!