Loading...
HomeMy WebLinkAbout0132796-Building (roof)~1 OSHKOSH ON THE WATER Job Address 1005 HIGH AVE CITY OF OSHKOSH No 132796 BUILDING PERMIT -APPLICATION AND RECORD Designer Category 211 -Alteration Industrial Owner AXLETECH INTERNATIONAL INC Create Date 09/03/2008 Contractor E D CHASE CO INC Plan Type ~ Building Q Sign (~ Canopy Q Fence Q Raze Zoning Class of Const: Size Unfinished/Basement Sq. Ft. Rooms Height Ft. ^ Projection Finished/Living Sq. Ft. Bedrooms `Stories Canopies Garage Sq. Ft. Baths Signs Foundation. Q Poured Concrete Q Floating Slab Q Pier ~ Other_ Q Concrete Block Q Post Q Treated Wood Occupancy Permit Not Required Occupancy Fee $0.00 Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use/Nature of Work pry: Repair miscellaneous areas of Built Up and Membrane Roof Systems. Remove and replace damaged insulation Densdeck over the insulation. Repair/replace vapor barriers, grouted concrete deck joints and slip sheets as needed. HVAC Contractor Electric Co ractc Fees: Va ti Issued By: \ Plumbing Contractor 000.00 Plan Approval $0.00 Permit Fee Paid $118.00 Park Dedication $0.00 Date 09/10/2008 Final/O.P.00/00/0000 ^ Permit Voided ~ Parcel Id # 0507610000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the Ci rongly urges the permit applicant to contact the easement holder(s) and to secure any ne a ap ovals before rting uch 'vi I have read and underst th ore entioned inf ation ~~~ Signature Date Agent/Owner ~ Address 5001 GREEN VALLEY RD OSHKOSH WI 54904 - 0000 Telephone Number 235-5220 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project fs ready. Page 1 of 2 Dannhoff, Allyn J. From: Terry Buss [tbuss@edchase.com] Sent: Wednesday, September 03, 2008 10:37 AM To: Dannhoff, Allyn J. Subject: Re: Axeltech repairs Yes, The address is Axeltech, 1005 High Street, 54901 Thanks, Terry B ---- Original Message ----- From: Dannhoff. Allyn J. To: Terry Buss Sent: Wednesday, September 03, 2008 10:17 AM Subject: RE: Axeltech repairs What is the address? Is the following an accurate Scope of Work? Scope of Work: Repair miscellaneous areas of Built Up and Membrane Roof Systems. Remove and replace damaged insulation with Poly-Iso with Densdeck over the insulation. Repair/replace vapor barriers, grouted concrete deck joints and slip sheets as needed. From: Terry Buss [mailto:tbuss@edchase.com] Sent: Wednesday, September 03, 2008 9:34 AM To: Dannhoff, Allyn J. Subject: Re: Axeltech repairs You could use $15,000 and I will let you know if we exceed that. We are not making any reaairs to the deck, It is OK, has grouted joints and has a vapor barrier that we are leaving in place unless it is rotted or loose. If we need to replace the vapor barrier we will inspect the joints, grout if necessary, and place a slip sheet over the joint prior to installing new vapor barrier materials. Terry Buss ----- Original Message ---- From: Dannhoff _Allyrn_J. To: Terrv Buss Sent: Wednesday, September 03, 2008 9:02 AM Subject: RE: Axeltech repairs Good Morning Terry; Do you have a ball park estimate or a "not to exceed" value that was given to Axel Tech? We can use this type of figure for the time being. See questions I have posed in your a-mail below Forward the standard value and roof assembly information and I will prepare the permit. If any questions come up, I will contact you. Thanks. Allyn 9/3/2008 Page 2 of 2 From: Terry Buss [mailto:tbuss@edchase.com] Sent: Wednesday, September 03, 2008 8:49 AM To: Dannhoff, Allyn J. Subject: Axeltech repairs Allyn, We are going to be doing some roof repair at Axeltech. Basically, this is over concrete decks that have an existing vapor barrier where leaks can interfere with operations by getting into electrical equipment. There will be some spot repair on Built-up roofs as well as some single ply. Are you repairing to the deck or just the top membrane? We will be going to go back with compatible materials in kind. The base will be polyiso and dens deck. All the materials used in the repairs would have a roofnav number if done as an entire system over a metal deck, but I do not think I can provide any over the concrete deck because roofnav does not address systems over concrete or such NC structures. That is my understanding anyway. With concrete decks, the state has given direction tha# the concrete serves as a 15 min. thermal barrier as long as any joints in the precast are solid grouted and in good shape (to limit heat transfer.} Some designers recommend a slip sheet over the joints to further reduce any chance of ma#erials seeping through the joints if there were any melting. I know that you stated that repairs of over, I believe, $1000 require a permit. This is a time and material situation, and while I am relatively sure that the amount will exceed $1000, I do not know what that figure will be. Can you advise me as to how you want us to handle this? TBuss 9/3/2008