Loading...
HomeMy WebLinkAboutHVAC D7-2440-0708 (7/30/08)~.~I~W f~l ON THE WATER July 30, 2008 Phil Steinhofer Hurckman Mechanical Ind. Inc. PO Box 10977 Green Bay, WI 54307-0977 John J Hogerty II Bergstrom Inc One Neenah Center Neenah, WI 54456 Site: BPG Triplex 3660 Jackson St Oshkosh WI 54901 For: Description: HVAC alterations Object Type: HVAC only Class of Construction: IIB - 8692 Sq Ft.; Occupancy: F: Factory /Industrial Plan Number: D7-2440-0708 City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) /Conditions: • IMC 606.4.1 The duct smoke detectors I'shall be connected to a fire alarm system. The actuation of a smoke detector shall activate a visible acid audible supervisory signal at a constantly attended location. • IMC 606.4.1 Exception 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identifies as air duct detector trouble. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). i C:`,(nneiii~ins.Pla~3 Rey irv:':Cumme:cial Plan Revirw ^_OO~'i(7;="_d?4-!??~?x ?ci~if) J:?ckson Si llv.a<-` Onf~~.doi Page 1 of 2 ' I SUBMIT: I • IMC 403.3.4 Balancing. Ventilation systems shall be balanced by an approved method. Such balancing shall verify that the ventilation system is capable of supplying the airflow rates required by Section 403. Balancing report required to be submitted prior to ftnal occupancy being allowed. • Comm 61.40 (4) Supervision. Prior to the initial occupancy of a new building or addition and prior to the final occupancy of an alteration of an existing building the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. j In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility. for designing a safe building, structure, or component. Inquiries concerning this correspondence maybe Respec rian oe Building Systems Consultant (920) 236-5051 Monday -Friday 7:30 A.M. to bnoe@ci.oshkosh.wi.us cc: Property file to me at the number listed below or the address on this letterhead. :30 A.M and 12:30 A.M to 1:30 P.M. Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 1:1(tia;t'.it i~ ~S'•Plan ReYie:e1C'~~mrre~,:wl I';ai~ itrv rw' "_Ou?i'•.(7;' ^_~#$f)-t)'Og ?ti6G a.~ckson $t I It-.~(:" Onh'.<lo~• Page 2 of 2