Loading...
HomeMy WebLinkAboutCertificate of OccupancyOat. 9, 1990 Ron Leiahtfuss 325 N. Sawyer Oshkosh, WI 54901 An Occupancy Permit is hereby granted for the new residence with attached garage located at 2381 Katy Court, Oshkosh, Wisconsin as described in Building Fermit Application number(s) 16252. This building is to be used only as a Single Family Residence and is in the R-1 Single Family Residence District. LIMITATIONSs Maximum floor loadings 40 lbs. per square foot live loading Maximum number of persona and/or living units: t living unit NOTE: A new Certificate of Occupancy shall be required prior to occupancy, should additional bulldin$(s) be created, or should any buildings mentioned above be altered or moved. The use of land, or buildings shall nat be changed until a Certificate of Occupancy is issued for that occupancy. ___.. BUILDING INSPECTOR ~. ~~ ~~ ~ ~~~ Chapter 21 WISCONSIN UNIFORM DWELLING CODE INSPECTION CHECKLIST a3~i Project Address: Owner: Permit #: ~~ 2 ~ Z Bu i 1 der : ~ ~.l.',GG~~tia!/ CHAPTER 21 - CONSTRUCTION STANDARDS DESIGN 21.03 Exits, Doors and Hallways (1) Two exits from first floor ~ (2) Egress windows from 2nd floor bedrooms or two exits from floor /" l/' ~~ (3 ) G~ ( 4 ) i (5) (6) (7> v" (8) /^ ~~~~. ~(8>(a> 20" wide x 24" high min. 46" sill height Two exits from 3rd floor Loft s More than 400 sq. ft. then stairway If 400 sq. ft. or less, then ladder ok Egress windows from basement bedrooms or two exits from floor If ground floor used for sleeping then exit to grade and another exit or bedroom egresa windows Doors Main exit - 3' x 6'8" Second exit - 2'8" x 6'8" Interior Circulation One-half of bedrooms - 2'8" x 6'8" door One full bathroom - 2'8" x 6'8" door Common use' areas - 2'8" door or 2'6" passageway Hallway -'3' wide 1989-21-48 Chapter 21 (10)(a> (b> (c> (d> 21.04 Stairs ~(1> ~! (1>(c> (1)(c>2. (1>(c)4. (2) ~` (2>(a> ~(2>(a> ~ (2)(c)1. ~ (2>(c>2. ~(2)(c>4. (2> ~ (2>(c>1. ~ (2>(c)2. ' /~i3> V (3>(a) ~~ (3>(b> Exit Balconies - treated wood, conc., steel Guardrail 3'' min., intermediate rails Maximum floor height 15 feet Minimum 3' x 3' Landings min. 3 ft. in travel direction Landing between door at head and foot of all stairs Except at head of interior stair when swing not over stair Except at head of interior stair, two or fewer risers, regardless of swing Except at head of exterior stair, three or fewer risers, at sliding glass door Exterior landing or platform not more than 8" below interior floor Handrails on stairs of more than three risers At least one provided Provided on 'all open sides Between 30 and 34 inches above nosing To prevent passage of objects over 9" dia. 1 1/2" clearance between rail and wall Withstand 200 lb. load in any direction Guardrails at elevation changes of over 24" At least 36" above floor To prevent passage of objects over 9" dia. Stairway Details 3 ft. wide Min. headroom of 6' 4" 1989-21-49 f ' Chapter 21 (3>(c> Max. riser of 8", min. tread of 9" ~(~3>(d> Winders per code ~ (3>(e> Spiral stairs per code Ladders per code 21.045 Ramps _~ (1>-(4) Ramps per code 21.05 L ght and Ventilation in h stable rooms (bedrooms in basements (1> 8X glazed openings ab only) (2)(a) 3.SX openable windows in all habitable rooms, kitchens and baths (or one air change per hour mech. vent.) /_(2)(b> Exhaust hoods terminate outside of dwelling (4) Crawl space vented, vapor barrier, organic matter removed (5> Safety glass in doors and sidelights 21.06 Ceiling Height ,~ Ceiling height-min. SOX of at least 7' 21.07 and Crawl Space Attic and crawl space access at least 14" x 24" 21.08 Firestopping, Draftstopping and Fire Separation ~(1><a) At floor levels (1)(b> At connections between concealed vertical and horizontal spaces (1)(c) At top and bottom of stairway stringers ,/~ (1m> Envelope homes wall passages lined, smoke detectors installed (3>(a) Above tenant separation ' and (b> (3)(c> Around chases (5) Garage separation per Table 21.08 ~,~ (5>(a> 45 min. wall and ceiling separation 21.04 Ladders (1) ,1989-21-50 Chapter 21 (5>(b> 20 min. door, solid core or metal _~ (5>(c> Noncombustible garage floor with drainage to drain or exterior 21.09 Smoke Detectors On each floor incl.' basement 21.10 D~e y Resistant Wood -~ (1>(a> Joists less than 18" from earth ~/ ; (1>(a> Girders less than 12" from earth / (1>(b> Sills less than 8".from earth _~ (.1)(d> Siding less than 6" from earth 21.11/Foam Plastic Insulation ~/ Protected with 15 minute finish FOOTINGS AND FOUNDATION INSPECTION' 21.12 Grade Slope away from dwelling 21.13 Excavations Proper protection of adjacent property 21.14 Excavations For Footing And Foundation (1> No excavations below footings unless reinforced (2> Soil undisturbed or compacted; no organics 21.15 Footings (1>(a) Continuous - 4" wider than wall, 8" deep (1>(b) Column - Z' x 2', l2" deep (1>(c> Trench (frost wall) - 8" wide (1>(d) Chimney and fireplace - 4" on each side, 12" deep 21.16 Frost Penetration Bottom of footing 'at least 48" below grade No footings placed on frozen soil 1989-21-51 Chapter 21 21.17 Drain Tiles~(Where Required) (2)(c) Exterior tale on Z" gravel, covered with 12" gravel t2>(d) Basement floor on 4" gravel (2>(e) Interior ti le connected to exterior ti le with bleeders every 8' (2)(f) Tile to sump pitched 1/8" per ft. (3> Drain ti le discharge per s. ILHR 82.36 21.18 Foundation General As wide as supported wall Lateral support at bottom (slab) and top (anchored floor) ' (1> Concrete - per ,Table 21.18-A - min. 3000 psi concrete (Z)(a) Unreinforced masonry per Table 21.18-B (2><b) Masonry reinforced w/pilasters per Table 21.18-C (2)(b) Masonry reinforced w/rebar per Table 21.18-D (2)(c) Lateral support at top and base of wall (3) Wood foundation - per NFPA Tech Report #7 - No galvanized fasteners 21.20 Concrete Floors At least three inch thick Four inch base course over clay snits 21.205 Wood basement floors Per NFPA Tech Report #7 FRAMING INSPECTION 21.22 Floors (1) Joists sized per span tables (1)(lm> Sill plates Any sill plates anchored Masonry walls -'Min. 2" x 6" sill plate or solid top course 1999-21-52 Chapter 21 (2> Truss joists properly installed (bearing points) (3> Girders or beams sized per 21.22-A1 or -A2 or Gen. Info. Notice #9 which is reprinted in UDC commentary s. ILHR 21.22(3) (Built-up wood beams to have double row of nails, nails spaced 18" in each row) (3>(a> Beam anchored to posts (4> Bearing 1 1/2" on wood, 3" on concrete or masonry Max. joist tail ends of 8" (5) Notching and boring (5>(a)1. Notching - max. 1/6 of depth not in mid 1/3 (5>(a>2. End notches not more than 1/4 of depth (5)(b> Boring - center of member, max. 1/3 of depth (6> Overhangs (6)(a) Max. 2 ft. where floor joists extend over wall (6)(b) Lookout joists attached to doubled floor joist with hangers set twice the overhang behind wall (7) Floor openings Doubled trimmers and headers if header over 4 ft. Hangers, beams or partition wall support if header over 6 ft. Hangers or ledger for tail joists over 8 ft. (8) Floor sheathing per Tables 21.22-8, C, D or E (8)(a) Plywood deck to have blocking, underlayment, wood strip flooring or T & G edges (9> Bridging every 8 ft. unless not required per NDS Wa11s 21.24 xterior Walls Weather-resistant Wall covering 1989-21-53 Chapter 21 21.25 Wood Frame Walls (1>(a) Stud size, grade and spacing per Table 21.25-A (1><b> Posts or multiple studs at corners (1)(d> Corner bracing (2> Proper top plate (3>(a) Header size per Tables 21.25-B, C or D (3)<b) Doubled shoulder stud for headers over 6' in bearing wall (3)<b>3. Single shoulder stud for headers over 6' if 2 x 6 construction (4) Stud not notched more than 1/3 of their depth <5) Load bearing partition over proper support 21.26 Masonry Wa lls (1) Proper cold weather work measure (3) Proper mortar per Table 21.26-A (7> Masonry Veneers (7)(a)1. Max. corbel of 1" (7)(a)2. Maintain air space (7)(a)3. Brick ledge or base flashing (7)(a)4. Weepholes every 4 ft. (8> Veneer Anchorage (8><a)1. Corrugated ties Max veneer unit size of 1 sq. ft. Tie every Z sq. ft. Embedded Z inches in point (8>(a)2. 1/4" dia. bolts for large units Each veneer unit w/3 anchors -or- units doweled to each other and wall anchor every 6 sq. ft. 1989-21-54 Chapter 21 (8>(b> Option of adhesive anchorage properly done (9> Framing member bearing - min. of 3" on masonry (14> Dampproofing of masonry foundations in clay soil Roofs and Ceili ngs 21.27 Roof Desi gn (1> Rafters and foists sized per span tables (3) Proper protection from water, 15 lb underlayment (4>(b) Crickets if chimney over 30" wide 21.28 Framing (1> 2X ridge board if rafters offset (2) Collar ties every third rafter ___ (4) Hip and valley rafters 2" wider than commons (4>(a) Doubled valley rafters unless supported (5> Trusses Wood grade marks per plan Proper load rating Bearing as indicated Diagonal supports to end walls as indicated Lateral support as indicated Lateral support of bottom chord as indicated No field modifications (6> Proper notching and boring of foists (7> Roof sheathing sized properly Edges supported or,clipped w/proper gap 1989-21-55 Chapter 21 FIREPLACE REQUIREMENTS 21.29 Masonry fireplaces (1> Flue size per Table 21.2,9 (3> Firebox - ~' Box of 1/4" metal, listed or 2" firebrick Walls at least 8" thick ~~(6) -Hearth extension per Table 21.29-1 (11) Combustible trim ~~ None within 6" of opening ~-~ Combustibles between 6" and 12" of opening not to project more - than 1/8" per inch from•opening (13) Combustible framing 2" away 21.30 Masonry chimneys - See Chapter 23 Checklist 21.31 Fireplace stoves To be listed 21.32 Factory-built fireplaces Listed (1) Installed per listing incl. clearances (3) Hearth extension per Table 21.32-1 1989-21-56