Loading...
HomeMy WebLinkAbout0131086-Electric (new service)CITY OF OSHKOSH No 131086 OSHKOSH ELECTRIC PERMIT -APPLICATION AND RECORD Re v ~ s e d ON THE WATER Job Address 3600 JACKSON ST Owner BERGSTROM OLDS-CADI GMC TK-NIBS 1- Create Date 06/27/2008 Contractor WITZKE ELECTRIC INC Category 652 -Industrial-New Building Wiring Plan Service New ~ Change ~ Temp 0 N/A Type Q Overhead (~ Underground Volts 277 / 480 Circuits 12 Luminaires Amps 2000 Switches Receptacles 12 Appliances Use/Nature of INDUSTRIAL /NEW 2000 AMP SERVICE, WELDERS, RECEPTACLES AND EQUIPMENT HOOK UPS '*debt acct Work Fees: Valuation $51,000.00 Plan Approval ' $0.00 Permit Fee Paid $366.00 Issued By: ^ Permit Voided Date 06/30/2008 Parcel Id # In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date AgenUOwner Address PO BOX 102 OSHKOSH W 1.54903 - 102 Telephone Number (920) 235-6572 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. CITY OF OSHKOSH No 131086 OSHKOSH ELECTRIC PERMIT -APPLICATION AND RECORD ON THE WATER Job Address 3650 JACKSON ST Owner BERGSTROM OLDS-CADI GMC TK-NIBS IP Create Date 06/27/2008 Contractor WITZKE ELECTRIC INC Category 652 -Industrial-New Building Wiring Plan Service New Q Change Q Temp Q N/A Type Q Overhead Q Underground ~ Volts 277 / 480 Circuits 12 Luminaires Amps 2000 Switches Receptacles 12 Appliances Use/Nature of Work NEW 2000 AMP SE PMENT HOOK UPS *'debt acct Fees: Valuation $51,000.00 Plan Approval $0.00 Permit Fee Paid $366.00 Issued By: ^ Permit Voided Date 06/30/2008 Parcel Id # 1519605800 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date ___- Agent/Owner Address PO BOX 102 OSHKOSH WI 54903 - 102 _ Telephone Number (920) 235-6572 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. JUN. 27.2008. 12~05PM WITZKE ELECTRIC ..,.., .....o.~osL Ji~•ision of enspeedon Services P.O. Bax l 130 Oshkosh, tiY! j4g03.1130 Phoae (920) 23&5050 Fax (920) 236.5084 ELECTRICAL. PERMIT APPLICATION ' All information after bold categories must be provided. Incomplete applications will noc be processed. N0.5~6~~.16~~7~p ~ ~ ~~ w ON TNF WAT@R • Application(s) and fee(s) cap be brought to Ciry Hall, Room 205 or mailed to L•~spect7on 5er`,ices, PO Box 1138, Oshkosh WI 'Sa903-1138, Cornmeneing work without permit(s) will result in fees being doubled or 5100,00 plus the normal permtt fee, which ever is greztcr. OR ~r„A...,.. - --- - , „~,~r h -- ~~ ~ mr re ,~c Ott v tr3 en v ad u 2 ~rn~3 cis t t wn>r t is or stud tlrr uP vour account DaTE 6 0 JOB a,DDR1rSS ~~ 6 Q~~I ~'„~+ .n. _ Coti"rR~CTOR_W i ~ z-k~ ^ f ~ c.:-Lr!'t^...~ n,~, CHECT{ ~ A.LL ~.PPLICA,BLE CSE CATEGORY ~Smgle 1=artilY ^Duplex p~iulti-Fzmily ^Re;ttal ' - f~Contyercial Iindustriel SERVICE CVcw ~OTetrporary /~11 L7Charge ,~ , T~'P8 ^Overhea~ C~Vot Applicable G~1ot .gpo,ccab,e ^Ltnder~ ot:ad FILL Iii TPiE ?.PPROPRLa=E BL,a``I; ti~ZTI3 TI3E ::ti'L_~R Volts ~C~'7 / ~ ~ phase _ - ~-aips 2©0~ Receptacles = ~ ~ Switches r Circuits = ~- Fixtures CI3ECI{ E7 AI.L ~,PPLIC~BLE aRange ^Di shwa,ner ' pFan OR Blower ^1=urnnce ~Garb~ge Disposal ^Dn•er ^~~'ator Hee:er QVlotors ~A,~C ^E1ect:ic Sign ^Gas Pumps ^Other DFSCRIPTIOti OF A_C,L ti'4'ORR;.6EI~G DO~~ ~ Z.~o•o ~" ~~7d~ .~__ 9 e ., _ . ~ ~ ~t tR.r~ Gets • , ti.aX'L~ (Including Labor and all a . ,_ I ~L3,STER ELECTRICL~~ a!# Enel~~ng lig~~ Gstures) ~~ D~ ~~~t ~~~ ;.~: Electric Permit Work Card Job Address 3600 JACKSON ST Permit Number 131086 Create Date 6/27!2008 Owner BERGSTROM OLDS-CADI GMC TK-NIBS IN Contractor WITZKE ELECTRIC INC Service New Q Change Q Temp ~ N/A Type ~ Overhead ~ Underground ~ N/A Volts 277 / 480 Circuits 12 Luminaires Amps 2000 Switches Receptacles 12 Value $51,000.00 Use/Nature 52 -Industrial-New Building Wiring INDUSTRIAL /NEW 2000 AMP SERVICE, WELDERS, RECEPTACLE of Work EQUIPMENT HOOK UPS ''debt acct rnspecvons: Date 07/01/2008 Type Consukation Inspector Kevin Benner__ approved w/cond. rounding, Service physical protection, declassification of the bottom 18" for a commercial repair garage. Date/Time requested: 06/30/2008 07:46 AM Notice Type: Ready Date(Time: 07/01/2008 09:30 AM Access: -Meet by the ftont door Requested by: WITZKE ELECTRIC INC Phone Number: 379-4967 Dan 0 Reinspect Fee 0 Fee Wavied ^ Reinspect Fee Paid ----------------------------------------------------------------------------------------------- Date 07/01/2008 Type Underground Inspector Kevin Benner approved Date/Time requested: 07/01/2008 01:45 PM Access: Requested by: WITZKE ELECTRIC INC Phone Number: 379-4967 Dan Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid ------------------------------------ ~ ---------------------- Date 08/19/2008 Type Service Ins ctor Kevin Benner approved w/cond. 5KAIC MCB .FP Test to be conducted rounding electrode conductor to be extended and connected to the structural steel. eviewed with Dan Cook Date/Time requested: 08/19/2008 08:30 AM Access• Requested by: WITZKE ELECTRIC INC Phone Number: 379-4967 Dan Reinspect Fee ~ Fee Wavied ^ Reinspect Fee Paid --------------------------------------------- ~ ------------------------ Date 08/28/2008 Type Re Service Ins ctor Kevin Benner to WPS 8/28!8 approved DatelTime requested: 08/28/2008 07:44 AM Notice Type: _ Ready Date/Time: 08/28/2008 07:44 AM Access: Notice Type: Ready Date/Time: 07/01/2008 00:00 PM Notice Type: Ready Date/Time: 08/19/2008 01:45 PM Requested by: WITZKE ELECTRIC INC Phone Number: 379-4967 Dan Reinspect Fee ~ Fee Wavied ^ Reinspect Fee Paid Square D®Ser-vices Electrical Equipment Test Report MOTOTRON GFR TESTING 25812667-001 sad`' 5~hneider Electric d :4~ ~:~.-~., August 27, 2008 MOTOTRON DAN COOK 920-379-4967 3650 JACKSON STREET OSHKOSH, WI 54901 Customer PO.: 0144810 Project: 25812667-001 Subject: Service Report Dear DAN COOK 920-379-4967, Enclosed please find the project documentation for the work performed by Square D Services at your OSHKOSH facility on 08/26/2008. In addition to this summary letter we have included test reports, drawings and other documentation as it applies to this project. Scope of Work Summary Square D Services performed preventive maintenance and testing services on all equipment in accordance with applicable industry standards . Recommendations /Conclusions No issues were noted during the project that resulted in specific recommendations; however, each specific test /inspection record may be reviewed for specific test and inspection values. Thank you for allowing Square D Services to assist you with this project. If you have any questions or concerns regarding this report or work performed please contact RUEGSEGGER TOM at 877-737-7697. Respectfully, Terry Michels FSR cc: Robert Fulton, Square D Services RUEGSEGGER TOM, Square D Services File ~ ~~ Services Division Sctal~%d~r Eie~ric LV Circuit Breaker ;~"'~`~"~~ '~"`' F:c~r,~- ~", 1-888-778-2733 (Manually Operated) REFERENCE INFORMATION Contact Name: DAN COOK 920-379- 4967 FSR: Teny Michels Job No: 25812667-001 Customer Site: MOTOTRON Customer Ref No: 0144810 DBID: 21-262030 3650 JACKSON STREET OSHKOSH, WI 54901 Date: August 26, 2008 IDENTFFICATION Sub Station Location: N/A Customer Asset ID: Service Entrance Sub ID: New 480 V Circuit ID: Main NAMEPLATE DATA Manufacture: Square D Manufacture Date: 08022 Serial No: 0640755604004 Type: RJ2000: Frame Size: 2000 Amps Rated Amps: 2000 Amps Sensor Rating: 2000 Amps Rating Plug: 2000 Amps Fuse Type: Unfused Fuse Manufacture: N/A Fuse Model/Catalog No: Fuse Rating: Trip Unit Type: Micrologic 6.OA Trip Curve No: 613-04 Interrupt Rating: 65000 KA . Mounting: Fixed Number of Operations: Number of Operations: INSPECTION CHECKLIST ITEM AS LEFT ITEM AS LEFT Blown Fuse Indicator (BFI): Not Applicable Switch Condition: Acceptable Interlocks: Acceptable Primary Disconnects: Acceptable Over-Travel Stops: Not Applicable Secondary Disconnects: Acceptable Mechanical Wear: Acceptable Ground Contacts: Not Applicable Mechanical Lubrication: Acceptable Main Contacts: Acceptable Intermediate Contacts: Not Applicable Arcing Contacts: Acceptable Trip Free Test: Acceptable Pri.Current Path Lubrication: Acceptable Manual Close Test: Acceptable Arc Chutes: Acceptable Spring Discharge: Not Applicable Interphase Barriers: Acceptable Insulated Linkages/Bracing: Acceptable Gap /Wipe Settings: Not Applicable Contact Alignment / Sequence: Not Applicable Test Report, 25812667 - 001 4. INSULATION- RESISTANCE TEST Test Equipment ID: Meg-803 Calibration Date: 1/22/08 FSR: 803 Test Voltage: 1,000 Tests are performed with breaker CLOSED and all unenergized poles grounded Tests are performed with breaker OPEN and all unenergized poles grounded AS FOUND AS LEFT AS FOUND AS LEFT AToB 90GS2 ALINE TO LOAD 90GS2 A To C 90 G S2 B LINE TO LOAD 90 G S2 BToC 90GS2 CLINE TO LOAD 90GS2 A TO GROUND 90 G S2 B TO GROUND 90 G S2 TEMPERATURE 70 °F C TO GROUND 90 G S2 HUMIDITY 40 CONTROL WIRING TEST Test Voltage: Kv As Found: As Left: CONTACT RESISTANCE TEST Test Equipment ID: Duc-803 Calibration Date: 1/22/08 FSR: 803 THROUGH PRIMARY DISCONNECT FINGERS AND/OR FUSES (IF APPLICABLE) BYPASS PRIMARY DISCONNECT FINGERS AND/OR FUSES (OR NO PRIMARY DISCONNECT FINGERS AND/OR FUSES) AS FOUND AS LEFT AS FOUND AS LEFT PHASE A PHASE A 11 N S2 PHASE B PHASE B 10NS2 PHASE C PHASE C 11 N S2 OVER CURRENT PROTECTION -TRIP UNIT DATA Test Equipment ID: FFTS-803 Calibration Date: 1/22/08 FSR: 803 Manufacture: Square D Trip Device Serial #: N/A Style: Micrologic 6.OA Battery Status As Found: Pass As Left: Pass Settings CT Coil Ratings: 2,000 CT Tap Ratings• 2,000 Rating Plug• 2,000 As Found Setting As Tested Setting As Left Setting I*2T ON As Found Setting As Tested Setting As Left Setting 1*2T ON Long Time Pickup 1 1 1 Instantaneous Pickup 2 2 2 Long Time Detay .5 .5 .5 Ground Fault Pickup 500 500 500 Short Time Pickup 1.5 1.5 1.5 Ground Fault Delay .1 .1 .1 Yes Short Time Delay .1 .1 .1 Yes TRIP UNIT TIMING TEST (measured in Seconds) Trip Device Function Test Current Amps Specified Range Phase A Phase B Phase C Amp Range Minimum Maximum As Found As Left As Found As Left As Found As Left Long Time 2,667 12 20 16.66 16.66 16.66 Short Time 3,500 1 2 1.45 1.45 1.45 Instantaneous 5,000 0.01 0.065 0.036 0.036 0.036 Ground Fault 1,000 0.08 0.15 0.144 0.144 0.144 Test Report, 25812667 - 001 5.