HomeMy WebLinkAboutProperty Maintenance - 9/4/1990CODE ENFORCEMENT DLVISION DEPABT:lENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOLATION/CORRECTION NOTICE DATE INSPECTED September 4 , 19 9 OCCITPANCY LNSPECTED Two Family Dwelling ADDRESS 203 West Irving Avenue OWNERS NAME Thomas Roblee & Wife . ADDRESS 1315 Kensington NOTICE DELIVERED/EXPLAINED T0: Mailed following complaint ' oe: ITEM # ORDER ~ FINDINGS OF LNSPECTION 1. 1633 (6) New front steps are being built without a permit and they do not meet current Codes. A permit shall be obtained. 2. 16-35 (2) The guadrails on the front porch are deteriorated and shal be replaced to Code. SEE ENCLOSURE 3. 16-35 (d) The storm door on the front shall be replaced. 4. 1635 (1) An inspection of the interior revealed that the walls and ceilings in the-first floor apartment were in poor condi- tion evith holes etc. All walls and ceilings. in the first floor unit shall be repaired to a smooth surface. 5. 1 634 2b Mechanical ventilation shall be installed in the showerroo in the first floor . ILHR82~.10 There is no~shutoff valve on 'rst floor toilet. 7. 16-35 (e~ The first floor bath door is off its hinges and shall be r hung .. 8. 16-33 (7 The smoke detector in the first floor is non-functional. 9. 16-35 (d Most of the windows are in poor condition and shall be re- paired and reglazed to stop cold air infiltration during win ter months. DEFICIENCIES MUST BE CORRECTED AND APPRO BEFORE CONCEALMENT. CALL (414) 236-5054 FOR I SPE ION. COMPLIANCE DATE: IMMEDIATELY ~ INSPECTOR: UCE K _ C CODE ENFORCEMENT DLVISION DEPABT:SENTOF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN VIOI.ATiON/CORRECTION NOTICE PAGE TWO DATE INSPECTED September 4 , 19 9 0 OCCUPANCY INSPECTED Two Family Dwelling ADDRESS 2 0 3 West I rvina Avenue OWNERS NAME Thomas Roblee ADDRESS NOTICE DELIVE.gED/EXPLAINED T0: ' ec: ITEM # ORDER ~ FINDINGS OF INSPECTION 10 18-79.1A The garage and side entry are obviously falling away from the main dwelling and continued movement can he noted due • to the cracking in the roofing tar along the dwelling and the sinking portion. The garage and side entry shall be removed from the property or jacked up to a level position and resupported at the foundation. A permit will be re- quired for this work. 11, 16-33 ,(6) The basement steps are in poor condition and shall be re- placed a comp ian an . 16-35 (3) The waterheater had a relief valve runoff tube which is too short and has a threaded end. The tube shall be re- placed with proper material. 13. 16- u~le~ and switch plates are missing in the lower front bedroom. 14. 16-33 (6) The carpeting on the interior stairs to the second floor shall be removed'as it is loose and creates a tripping hazard. 15. 16-33 (6) There is no handrail on the side entry steps. A reinspection will be made on September 14 1990 to assur compliance. DEFICIENCIES MUST HE CORRECTED AND APP VED B FORE CONCEALMENT. CALL (4l4) 236-SOSq FOR NSPE ON. COMPLIANCE DATE: IMMEDIATELY ~ INSPEC?OR: