HomeMy WebLinkAbout0092675-Plumbing (interior)OSHKOSH
ON THE WATER
Job Address 1360 JUDY LEE CT
CITY OF OSHKOSH
PLUMBING PERMIT -APPLICATION AND RECORD
Contractor P&S PLUMBING
Bathtub 1 Shower
Whirlpool 1 Floor Drain
Lavatory 4 Lndry Tray
Toilet 3 Lndry Stndp
Res. Sink 1 Disposal
Bar Sink 0 Dishwasher
Water Heater 1 Sump Pump
Site Drain 0 Classnn Sink
Roof Drain 0 Breakrm Sink
Use/Nature
of Work
Owner
Size Material Type # Conn. Type
Sanitary Sewer 0
0
0
0
0
Stone Sewer 0
0
0
0
0
Water Service p
0
0
0
0
Valuation $8,200.00 Plan Approval $0.00 Permit Fees $102.00
Issued By Date 02/15/2002
Permit Voided
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. /
Signature ~`Z..-sue /y n '~~j ~~ c Date 2 ~l ,S/ c Z
Agent/Owner
Address PO BOX 2153 APPLETON WI 54913 - 0000 Telephone Number 734-3912
1 Ejector/Grind
1 Water Softner
0 Local Waste
1 Clothes Wshr
1 Bidet
1 Beer Tap
1 Dent.Oper.
0 Lab Sink
0 Sterilizer
Category 410 -Residential-Interior
0 Dip Well 0 F Prep Sink
0 Drink Ftn 0 Serv Sink
0 Wait. St. 0 Shamp Sink
0 Ice Chest 0 FIrIVUst Sink
0 Exam Sink 0 Catch Basin
0 Sculry Sink 0 Wash Ftn
0 Hand Sink 0 Urinal
0 Plaster Sink 0 Standp Rec
0 Surgeons Sink 0 Ice Maker
No 92675
Create Date 11/26/2001
Plan
0 Gar Drain _
0 Soda Disp
0 Coffee Maker
~ Int Grease Trap
~ Ext Grease Trap
0
0
0
0
0
0
0
0
0
NSFR
Plumbing Permit Work Card
Job Address 1360 JUDY LEE CT Permit Number 92675
Owner Contractor P&S PLUMBING
egory 410 -Residential-Interior Plan
uathtub ~ 1 Shower / 1 Ejector/Grind 0 Dip Well 0 F Prep Sink
Whirlpool ~ Floor Drain ~ Water Softner 0 Drink Ftn 0 Serv Sink
Lavatory 1l _
1 ~ 1 ! 4 Lndry Tray 0 Local Waste 0 Wait. St. 0 Shamp Sink
Toilet '~ Lndry Stndp ~ Clothes Wshr 0 Ice Chest 0 Flr/Wst Sink
Res. Sink ~ Disposal ~ 1 Bidet 0 Exam Sink 0 Catch Basin
Bar Sink 0 Dishwasher ~ Beer Tap 0 Sculry Sink 0 Wash Ftn
Water Heater -L' Sump Pump I
~ Dent. Oper. 0 Hand Sink 0 Urinal
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker
Use/Nature
of Work
Value $8,200.00
0 Gar Drain 0
0 Soda Disp 0
0 Coffee Maker 0
p Int Grease Trap 0
0 Ext Grease Trap 0
0
0
0
0
NSFR
Size Material Type # Conn.Type
Sanitary Sewer p ~~ ~ ?- ~ FF ~ 4?~
0
0
Storm Sewer p ~ .~~
,~ ~ r:5
0
0
0
Water Service 0
0
0
0 .-
0
Date Type Inspector ~ Approved
e
~6~~~w c
~ ~~ ~S ct~
~g,~3~~~
Create Date 11/26/2001
WATER CALCULATION WORKSHEET FOR ~ 3 ~ o S ~f ~ i L [~~~ c c N 2~
NAME OF PROJECT
INFORMATION REQUIRED TQ CALCULATE WATER SERVICE SIZE
1': Demand of building in building in gallons per minute. ' WSFU's Z ~ _ (GPM). / ~
t
2. _ Difference in elevation from main or extemal pressure tankto building..control-valve. (feet)
3. Size of water meter (when meter is required) 5/8" ~, 3/4" ~ 1" _, 1-1/2~ ~, 2" _, larger size
_r
4. Developed length from main ar externak;pressure tank to building control valve. (feet) / / 5
5. Low pressure at main in-street or external pressure tank. (psi)
CALCULATE WATER SERVICE PRESSURE LOSS
6. Low pressure at main in street or external pressure tank. (value of # 5 above) ~ ` ~
7. Determine pressure loss due to friction in 1 ~~/ inch diameter
water service. Subtract value of "7" ~l. ~ 3
(Water service piping material is P [- ~ S T - c )
subtotal 3 (~ 3'7
8. Determine pressure loss due to elevation,
(multiply the value of # 2 above by .434) Subtract value of "8" 3 , `/ 7
9. Available pressure after the bldg. control valve. (enter in "B" below) subtotal '2'1.9
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A")
B. Available pressure after the bldg. control valve. (from "9" above) Value of "B" 2 `~~~
C. Pressure loss of water meter (when meter is required) Subtract value of "C" ~
D. Pressure at controlling fixture.
(Controlling fixture is u~
E. Difference in elevation between the building control valve
and the controlling fixture in feet ~ X .434 psi/ft.
~, ~ e
F. Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture.
(Pressure loss due to )
G. Developed length from building control valve to controlling
fixture in feet ~ X 1.5
(Water distribution piping material is `~r9 " c cpPc~TZ )
subtotal 2 ? . ~l
Subtract value of "D" ~
subtotal / ~
Subtract value of "E" 3 ,`/ ~"7
subtotal / /. ~ / ~,
Subtract value of "F" - ~ -
subtotal
Divide by value of "G" o S
subtotal • /o' ~
Multiply by
100
A. Pressure available for uniform loss "A" _ ! y, £~~
SBD -6479 (R11/98)
WATER DISTRIBUTION DATASHEET
Date: February 15, 2002
Name: P & S PLUMBING
Street:
City:
Project: NSFR
Street: 1360 JUDY LEE CT
City:
1. 17.6 Gallon per minute buiding demand, predominatly Flush Tank.
2. 40.0 Low pressure at the Main in Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in Street to the Water Meter.
4a. 1.7 Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop.
Pressure loss detemined using a C value of 130 ,inside diameter of .995 and a velocity of 7.3 ft per sec.
4b. 7.5 Lb loss from a 115.0 ft 11/4" PE Tubing CTS ASTM 2737 AWWA C901 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150 ,inside diameter of 1.060 and a velocity of 6.4 ft per sec.
5. 4.6 Lb loss from a 3/4in Meter
6. 26.1 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = B-(C+D+E) x 100
F
A. 14 Pressure available for uniform loss (psi/100 feet of pipe).
B. 26.1 Lbs of pressure available at the Water Meter.
C. 8.0 Pressure needed at the controlling fixture. T/S FAUCET
D. 4.3 Lb loss resulting from a 10.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a WTR SFNR serving the controlling fixture.
F. 105.0 Ft Developed length from the 70.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 6 0 18 34 62 112 270 484 776 1835
Fixture Listing
Date: February 15, 2002
Name: P & S PLUMBING Project: NSFR
Street: Street: 1360 JUDY LEE CT
City: City:
Non Public Use Fixtures
Hnt ('n1A Tntal
1 Automatic Clothes Washer 1.00 1.00 1.50
2 Bathtub, with or without shower head 3.00 3.00 4.00
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
4 Lavatory 2.00 2.00 4.00
1 Shower, per head 1.00 1.00 1.50
3 Water Closet, gravity type flush tank .00 6.00 6.00
Public Use Fixtures
Hot Cold Total
1 Ice Maker .00 .50 .50
Total Water Supply Fixture Units 9.00 20.50 26.00
17.6 Gallon per minute demand of the building. Predominatly Flush Tank
13.1 Pressure available for uniform loss. For the table use - 14.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 I/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 150 150 150 150 150 150 150 150 I50 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 6 0 18 34 62 112 270 484 776 1835
~~