Loading...
HomeMy WebLinkAbout0094951-Plumbing (interior)OSHKOSH ON THE WATER Job Address 1320 JUDY LEE CT Contractor O'NEILL ENTERPRISE INC Bathtub 2 Shower Whirlpool 0 Floor Drain Lavatory 3 Lndry Tray Toilet 3 Lndry Stndp Res. Sink 1 Disposal Bar Sink 0 Dishwasher Water Heater 1 Sump Pump Site Drain 0 Classrm Sink Roof Drain 0 Breakrm Sink Use/Nature of Work Size Material Type # Conn. Type Sanitary Sewer 0 0 0 0 0 Storm Sewer p 0 0 0 0 Water Service 0 0 0 0 0 Owner Category 410 -Residential-Interior 1 Ejector/Grind 0 Dip Well 0 F Prep Sink 1 Water Softner 0 Drink Ftn 0 Serv Sink 1 Local Waste 0 Wait. St. 0 Shamp Sink 1 Clothes Wshr 0 Ice Chest 0 FIrIWst Sink 1 Bidet 0 Exam Sink 0 Catch Basin 1 Beer Tap 0 Sculry Sink 0 Wash Ftn 1 Dent. Oper. 0 Hand Sink 0 Urinal 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0 Sterilizer 0 Surgeons Sink 0 Ice Maker Valuation $7,000.00 Plan Approval $0.00 Permit Fees $102.00 Issued By CITY OF OSHKOSH PLUMBING PERMIT -APPLICATION AND RECORD 0 Gar Drain 0 0 Soda Disp 0 0 Coffee Maker 0 0 Int Grease Trap 0 0 Ext Grease Trap 0 0 0 0 0 NSFR Permit Voided Date 06/07/2002 In the performance of this work, I agree to pertorm all work pursuant to rules governing the described construction. Signature Date Agent/Owner No 94951 Create Date 04/15/2002 Plan Address 5575 CTY RD N PICKETT WI 54964 - 0000 Telephone Number 428-4700 589-2007 d Plumbing Permit Work Car p L[ q S Job Address 1320 JUDY LEE CT Permi t Number 0 / ( / / Owner Contractor O'NEILL ENTERPRISE INC . ",tegory Plan .htub Shower 1 ~ Ejector/Grind 0 Dip Well 0 F Prep Sink Whirlpool 0 Floor Drain ~ _~9' Water Softner 0 Drink Ftn 0 Serv Sink Lavatory ~ .0~Lndry Tray ~-t)' Local Waste 0 Wait. St. 0 Shamp Sink Toilet 3 ~Lndry Stndp jClothes Wshr 0 Ice Chest 0 Flr/Wst Sink Res. Sink I ,6~Disposal _~,r8' Bidet 0 Exam Sink 0 Catch Basin Bar Sink 0 Dishwasher 1 ~ Beer Tap 0 Sculry Sink 0 Wash Ftn Water Heater _L.e~Sump Pump ^.e' Dent. Oper. 0 Hand Sink 0 Urinal Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker Use/Nature _- -- - - - - - - of Work Size Material Type # Sanitary Sewer 0 0 0 0 0 Storm Sewer 0 0 0 0 0 Water Service 0 0 0 0 0 Date Type Rough In ~ Inspector (Request Line .ji ~r`ground & above RI - NO PERMIT 3~~ Date/Time requested: 6/4/02 03:32 PM Notice Type: Telephone Number: Access: Ready Date/Time: 6/4/02 03:32 PM Requested By: ^ Reinspect Fee ^ Fee Waived ^ Reinspect Fee Paid -------------------- ------------------------------------------------------------------------------------ r ,.% f l ° Value $0.00 0 Gar Drain 0 0 Soda Disp 0 0 Coffee Maker 0 0 Int Grease Trap 0 p Ext Grease Trap 0 0 0 0 0 / ~ -Z- ~ ~ ~ ~~~~ c~' ~ j~ ~- Create Date 04/15/2002 Conn.Type -~- WATER DISTRIBUTION DATASHEET Date: July 22, 2002 Name: O'NEILL ENT Project: NSFR Street: City: Street: 1320 JUDY LEE CT City: 1. 16.1 Gallon per minute buiding demand, predominatly Flush Tank. 2. 43.0 Low pressure at the Main in the Street. 3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter. 4a. 1.1 Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop. Pressure loss detemined using a C value of 150 ,inside diameter of .995 and a velocity of 6.6 ft per sec. 4b. 3.4 Lb loss from a 45.0 ft 1" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter. Pressure loss detemined using a C value of 150 ,inside diameter of .995 and a velocity of 6.6 ft per sec. 5. 3.9 Lb loss from a 3/4in Meter 6. 34.6 Lbs of pressure available at the Water Meter. This value is entered in (B) below. The (A) value listed below is determined by using the following formula, then rounding the result up. A _ B- C+D+E x 100 F A. 19 Pressure available for uniform loss (psi/100 feet of pipe). B. 34.6 Lbs of pressure available at the Water Meter. C. 20.0 Pressure needed at the controlling fixture. SHWR-MASTER BATH D. 3.5 Lb loss resulting from a 8.0 ft difference in elevation from the Water Meter to the controlling fixture. E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture. F. 60.0 Ft Developed length from the 40.0 ft actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7 0 18 34 62 112 270 484 776 1835 2 ` ~~ 8.0 K5 1.is' I ~~ ~ 3.S DW l WATER CALCULATION WORKSHEET FOR _r'3?A Sc,~aly 1'ee rpu.-~- Z~ ~` f1r~ ~(~ q'~'~ (•S' k.T t .S' wwe of ~to.r~cr 1NFORMATiON REQUIRED TO CALCULATE WATER SERVICE $1ZE 'I. Demand of building in building in gallons per minute. WSFU's ~~ = {GPM} 15.8 2. Difference in elevation from main or external pressure tank to building control valve. (feet) Z 3• Size of water meter (when meter is required) 5/8'_, 3/4' ~ 1" ~, j_1~" _, 2"= [anger size 4. Developed length from main or extemai pressure tank to~ building control valve, {feet) yS 5. Low pressure at main in street or extemat pressure tank {psi) 43 CALCULATE WATER SERVICE PRESSURE LOSS fi. Low pressure at main in street or external pressure tank. (value of # ~ above) 4 3 7• Determine pressure foss due to friction in =inch diameter water service. Subtract value of "7" 3.C. (Water service piping material is -Copper TYPe L j ex.gS o subtotal ~.y 8. Determine pressure loss due to elevation, ~ - (mul6iply the value of # 2 above by .434) Subtract value of "i3" . ~ _~ 9. • Available pressure after the bldg. control valve. (enter in "13" below) subtotal ~„ s332 CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A") B. Available pressure after the bldg. control valve. (from "9" above} Value of "8" a$"532 C. Pressure loss of water meter (when meter is required) Subtract value of "C" 3 subtatat a 3.532 D. Pressure at controlling fixture. {Controlling fixture is P$/ ~ ~ E. Difference in elevation between the building control valve and the controlling fixture in feet 8 X .434 psi/ft. F. Pressure loss due to water treatment devices, instantaneous water heaters and backflow preventers which serve the controlling fixture. (Pressure loss due to a G. Developed length from building control valve io controlling fixture in feet yb X t .5 {Water distribution piping material is C~D~e.~-~~! A. Pressure available for uniform loss Subtract value of "C" ZO subtotal I x.532 Subtract value of "E" 3,a'it subtotal iL .«o Subtract value of "F" ~ subtotal IZ. ~ Divide by value of "G" fro subtotal O.Ze~ Multiply by 100 «A~t ~ Fixture Listing Date: July 22, 2002 Name: O'NEILL Street: Street: 1320 JUDY LEE CT City: City: Non Public Use Fixtures U~* r•~,~ T~*~, 1 Automatic Clothes Washer 1.00 1.00 1.50 1 Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1/2" diameter .00 6.00 6.00 1 Kitchen Sink 1.00 I.00 1.50 1 Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50 2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00 1 Shower Stall, lavatory and water closet FT -group 1.50 3.00 3.50 Public Use Fixtures Hot Cold Total 1 Ice Maker .00 .50 .50 Total Water Supply Fixture Units 9.50 19.50 23.50 16.1 Gallon per minute demand of the building. Predominatly Flush Tank 18.6 Pressure available for uniform loss. For the table use - 19.0 Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7 0 18 34 62 112 270 484 776 1835 Project: NSFR Fixture Listing Date: July 22, 2002 Name: O'NEILL ENT Street: Street: 1320 JUDY LEE CT City: City: Non Public Use Fixtures Fint Cnlrl Tntal 1 Automatic Clothes Washer 1.00 1.00 1.50 1 Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1/2" diameter .00 6.00 6.00 1 Kitchen Sink 1.00 1.00 1.50 1 Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50 2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00 1 Shower Stall, lavatory and water closet FT -group ] .50 3.00 3.50 Public Use Fixtures Hot Cold Total 1 Ice Maker .00 .50 .50 Total Water Supply Fixture Units Project: NSFR 9.50 19.50 23.50 16.1 Gallon per minute demand of the building. Predominatly Flush Tank 18.6 Pressure available for uniform loss. For the table use - 19.0 Maximun Allowable load for Crosslinked Polyethylene (Pex) Tubing ASTM F876 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0 Value of C 150 150 150 I50 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 4 6.5 9 15 22 31 53 0 0 0 Maximum FM WSFU 0 0 0 5 7 IS 58 0 0 0 Maximum FT WSFU 4 8 11.5 21.5 35 58 142 0 0 0 WATER DISTRIBUTION DATASHEET Date: July 22, 2002 Name: O'NEILL ENT Street: City: Project: NSFR Street: 1320 JUDY LEE CT City: 1. 16.1 Gallon per minute buiding demand, predominatly Flush Tank. 2. 43.0 Low pressure at the Main in the Street. 3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter. 4a. 1.1 Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop. Pressure loss detemined using a C value of 150 ,inside diameter of .995 and a velocity of 6.6 ft per sec. 4b. 3.4 Lb loss from a 45.0 ft 1" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter. Pressure loss detemined using a C value of 150 ,inside diameter of .995 and a velocity of 6.6 ft per sec. 5. 3.9 Lb loss from a 3/4in Meter 6. 34.6 Lbs of pressure available at the Water Meter. This value is entered in (B) below. The (A) value listed below is determined by using the following formula, then rounding the result up. A - B- C+D+E x 100 F A. 19 Pressure available for uniform loss (psi/100 feet of pipe). B. 34.6 Lbs of pressure available at the Water Meter. C. 20.0 Pressure needed at the controlling fixture. SHWR-MASTER BATH D. 3.5 Lb loss resulting from a 8.0 ft difference in elevation from the Water Meter to the controlling fixture. E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture. F. 60.0 Ft Developed length from the 40.0 ft actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Crosslinked Polyethylene (Pex) Tubing ASTM F876 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0 Value of C 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 4 6.5 9 15 22 31 53 0 0 0 Maximum FM WSFU 0 0 0 5 7 15 58 0 0 0 Maximum FT WSFU 4 8 11.5 21.5 35 58 142 0 0 0