HomeMy WebLinkAbout0128572-Building Building Permit Work Card Job Address 300 -350 N KOELLER ST Permit Number 0128572 Create Date 1/14/2008 Owner BROS LLC Contractor R J ALBRIGHT INC. Category 231 - Addition Stores & Customer Service Plan ZZ4- 2193 -1107 Occupany Permit Required Flood Plain Height Permit Class of Const: 2Bibc Use /Nature Commercial / Work above the foundation for addition to combine two buildings into one. Remodel facade of existing buildings. of Work 3431 SF, 39' x 88'. HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Note Inspector Allyn Dannhoff Spoke to Adam H (Excell) about the foam insul on the roof. He is diving into it, says the supplier /manufacturer has some form of approval from the state allowing the EPS to be used without a thermal barrier. Date/Time requested: 1/24/2008 01:22 PM Notice Type: Ready Date/Time: 1/24/2008 01:22 PM Access: Requested By: Phone Number: O Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Page 1 of 1 JUL -21 -2008 MON 11:53 AM EXCEL ENGINEERING FAX NO. 9209269801 P. 04 Buildings, HVAC Compliance Statement SBD -9720 707970 Anytime Fitness/Koeller s This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of protects within buildings with total areas exceeding 50,000 cubic feet or greater and bleachers (Comm 50.10 /Comm 61.50). Failure to submit this form may result in penalties as specified in Comm 50.26 /Comm 61.23 and/or local ordinances. This form must be submitted prior to the plan approval expiration date or another submittal may be required. General Instructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and signed form to: City of Oshkosh -Div. of Inspection Service 215 Church Ave., -PO Box 1130 - Oshkosh, WI 54903 -1130 Note: If the review was done by the municipality, the compliance statement goes only to the municipal building inspector. Personal Information you provide may be used for secondary purposes [Privacy Law, x.15.04 (1)(m)). 1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. Transaction ID Number Z2 2042 - 0807 Site Number NIA Site location (number & street) 312N. Koeller St. l I City Q Village ❑ Town Of Oshkosh County of Winnebago 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary). Check those which apply: Q Building Object !DO 1159275 0 HVAC Object ID# Q Lighting Object ID# ❑ Partial Completion _ DesPription of Portion Completed A) R Statement of Substantial Compliance To the best of my knowledge, belief, and based on onsite observation, construction of the following building and/or HVAC Items applicable to thls project have been completed in substantial compliance with the approved plans and specifications. BUILDING/LIGHTING ITEMS 1. Structural system Including submittal and erection of all building 10. Exterior lighting 8. control requirements components (trusses, precast, metal building, etc.) 11. Interior lighting & control requirements 2. Fire protection systems (sprinklers, alarms, smoke detectors) 12. All conditions of lighting plan approval designed, Installed, and tested (including forward flow on back flow and applicable variances devices) by appropriately registered professionals. 3. Shaft and stairway enclosure Q HVAC ITEMS 4. Exits Including exit and directional lights 1, HVAC system Including final test 5. Fire - resistive conetructlon, enclosure of hazards, fire walls, labeled 2. All conditions of HVAC plan approval doors, class of construction, fire stopped penetrations and applicable variances 6. Sanitation system (toilets, sinks, drinking facilities) 7. Barrier -free Including Comm 18 elevators and lifts 8. Energy envelope requirements 9. Alt conditions of building plan approval and applicable variances The following Items are not In compliance and must be addressed: .,. .T,Q CV- . • B) ❑ Statement of Noncompliance Due to the following listed violations, this project is not ready for occupancy: C) Q Supervising Professional Withdrawn From Project (use A of above to Indicate project status as of this date.) D) ❑ Project Abandoned 3. SUPERVISING PROFESSIONAL SIGNATURE FOR: Q Building ❑ HVAC ❑ Lighting Adam Helndel, AIA, LEED AP Date: 1 - 2,.%.006 Name (please print or type) Phone # 9204264800 Customer ID# N/A Signature � � 1 $BD -9720 (R.02121104) _s'3v Building Permit Work Card Job Address 300 -316 N KOELLER ST Permit Number 0000000 Create Date 11/5/2007 Owner BROS LLC Contractor R J ALBRIGHT INC. Category 222 - Addition Offices, Banks, Professional Plan Occupany Permit Flood Plain _ Height Permit Class of Const: _ Use /Nature Addition to combine tenant spaces. of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Footings Inspector Allyn Dannhoff�� we) 0,74 equest in if 6, 0 A- e fteep Date /Time requested: 11/5/2007 08:02 AM Notice Type: Ready Date /Time: 11/5/2007 08:02 AM Access: Requested By: Del Rar - Laurie Phone Number: 920 - 731 -5464 Reinspect Fee O Fee Waived ❑ Reinspect Fee Paid Page 1 of 1 CITY OF OSHKOSH - DEPT. OF COMMUNITY DEVELOPMENT SITE PLAN REVIEW - ZONING Location of Property: 312 N. Koeller Street Date: 10/24/07 Applicant Name: Adam Heindel, Excel Engineering, Inc. Phone: 920 - 926 -9800 Fax 920 - 926 -9801 Applicant Address: 100 Camelot Drive City: Fond du Lac State: WI Zip: 54935 Owner: Bros LLC Parcel Number(s): 16- 0870 -1100 Zoning: C -2 PD Hwy 41 Type of Construction: Renovate existing retail buildings and join with 3,431 s.f. addition Compliance Checklist Use Height Asset Landscaping Let - Width Rent-Setback Parking-Standards Lighting Let - Dept)} Loading-Randards Signage Lot Aron uce Mechanical Screening Eleedplain Rear Setback Trap Yard Stand Var. /CUP/PD Conditions AjcPeft Building-Area Screening Other: Hwy 41 Comments /Conditions 1. NOTE: Planned Development/Condition Use Permit authorized 10/09/07 (see Res. 07 -282). 2. CONDITION: Per Res. 07 -282, the land area shall be consolidated into a single parcel as proposed. 3. CONDITION: Per Res. 07 -282, base standard modifications to reduce the front and transitional yard setbacks. 4. CONDITION: Dumpster location approved but details not submitted to date. Must comply with Section 30- 34(D)(7)© 5. CONDITION: Landscaping quantities exceed requirements. However, the two western-most and one southern parking lot landscape islands need to incorporate plantings. Plans show no plantings. 6. CONDITION: Photometric plan submitted and is NOT approved. Exterior lighting cannot exceed 0.5 footcandles at the property line. Plans show eastern lot line in violation as well as portions along the south lot line and north lot lines. No exterior lighting shall be installed until a revised photometric plan is re- submitted and approved. 7. NOTE: Signage is not part of this review, as it is not supplied. No signage shall be installed until a signage plan is supplied and approved by the Department of Community Development. 8. CONDITION: No mechanical equipment shown on submitted plans. All rooftop and ground level mechanical equipment and utilities must be screened in accordance with Section 30 -35 (I)(5) and not be located within required setbacks. 9. CONDITION: Per Res. 07 -282, grading, storm water and drainage plans are reviewed and approved by the Department of Public Works. 10. CONDITION: Per Res. 07 -282, applicant must incorporate further windows or other elements on the north and east facades. * *THIS REVIEW IS FOR ZONING PURPOSES ONLY. CONTACT INSPECTION SERVICES (920- 236 -5050) PRIOR TO PERMIT ISSUANCE TO DETERMINE IF MORE INFORMATION IS NEEDED ** ** *REVIEW FEE NOT COLLECTED TO DATE. APPLICANT MUST REMIT PRIOR TO PERMIT ISSUANCE * ** Review Fee: $200.00 ❑ Approved © Approved w /Conditions ❑ Denied ❑ Hold Reviewed by: Todd Muehrer Review Date: 10/31/07 Please contact the Zoning Administrator at 920.236.5059 if you have any questions. REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and when no change is proposed. COPY: Planning Address File Engineering E IVED Safety and Buildings 4003 N KINNEY COULEE RD commerce.wi.gov LA CROSSE WI 54601 -1831 NOV O 7 2D07 TDD #: (608) 264 -8777 f i sconsin www•commerce.wi.gov /sb/ Department of Commerce C * _;� lL4 ; F www.wisconsin.gov C Jim Doyle, Governor Ic - ", ;N CFP\, e`, i }',!/1 ^ "� In Mary P. Burke, Secretary November 05, 2007 CUST ID No. 1046066 ATTN :• Buildings & Structures Inspector ADAM HEINDEL BUILDING INSPECTION EXCEL ENGINEERING CITY OF OSHKOSH 100 CAMELOT DRIVE POB 1130 FOND DU LAC WI 54935 OSHKOSH WI 54902 FOOTING FOUNDATION APPROVAL Identification Numbers PLAN APPROVAL EXPIRES: 11/05/2089 Transaction ID No. 1478421 Site ID No. 731939 SITE Please refer to both identification numbers, Bros Koeller above, in all correspondence with the agency. 312 N Koeller Drive City of Oshkosh FOR: Facility: 685322 BROS KOELLER 312 N KOELLER DRIVE Tenant Name or Addn/Alt Description: Building additions (39' x 88' & 1' x 20' extensions) multi -tenant bldg Object Type: Building ICC Regulated Object ID No.: 1159275 Major Occupancy: Mercantile; Type IIB Metal Frame Unprotected class of construction; Addition- Alteration plan; 25,175 project sq ft; Unsprinklered; Occupancy: A -2 Dining & Drinking, B Business, M Mercantile; Allowable area determined by: Fire Walls The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED to allow construction of the Footings and Foundations only, for the subject project prior to review and approval of the full building plans by this department. The owner, as defined in s. 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. Prior to the start of construction, all applicable building permits should be obtained from the local authorities having jurisdiction in accordance with local laws and ordinances. Nothing in this approval limits the power of municipalities to make, or enforce, additional or more stringent regulations, providing the regulations do not conflict with this code or any other rule of the department, or law. DEPARTMENT CONDITIONS • If this project is in an unsewered area, a sanitary permit must be obtained prior to the issuance of a local building permit. • This approval is only for footing and foundation work. Construction of the remainder of the building shall not take place prior to departmental review and conditional approval of the construction plans. • If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 7 days prior to any earth disturbing activities. You will need to either file the NOI and an erosion control plan summary on -line at www.commerce.wi.gov /sb or submit a completed NOI form and either a plan summary or complete plan to us, with additional fees, or to the certified municipality. • This "Permission to Start" does not include permission to install any underground plumbing, including sanitary/storm sewers, or water or mains. All projects needing submittal per Comm Tables 82.20 -1 &2 must have complete plumbing plans, application, & fees submitted and approved prior to commencement of any plumbing work. ADAM HEINDEL Page 2 11/5/2007 Submit • Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations, and appropriate fees are required to be submitted for review and approval prior to installation. The submitted HVAC plans shall match the approved building plans. Note as per Comm 2.10 installation of HVAC without approved plans could result in double fees. • Comm 61.30(3) Submit, prior to installation, one (1) set of properly signed and sealed metal building plans, a completed SB -118 application form including this transaction number and signed by the building designer, and $100 submittal fee to the designated Safety & Buildings Office. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submittal may be an additional $200. Reminders • Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code and properly signed and sealed. The plans shall be available at the job site as requested by the Department representative or local official. • IBC 703.2 Provide rated wall source on the plans and specifications to show how rated assemblies are being provided to meet the design ratings proposed at the different design locations. • IBC 705.5.1 Provide wall extensions to properly protect at east & northwest ends of fire wall. Also provide parapets at fire wall to adjacent buildings on the same lot per this section or meet one of the exceptions. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per statute 101.12(2), Wisconsin Statutes, nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely a Fee Required $ 300.00 if Fee Received $ 300.00 Balance Due $ 0.00 Jack A Miller Building Plan Reviewer, Integrated Services WiSMART code: 7648 (608) 785 -9348, Fax: (608) 785 -9330, M - F 7:45 am - 4:30 pm jack.miller@wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014, Monday, 7:45A.M.- 4:30P.M. Randy Schmiedel, Bros LLC Safety and Buildings 4003 N KINNEY COULEE RD commerce.wi.gov LA CROSSE WI 54601 -1831 It • ■ TDD #: (608) 264 -8777 i sco n s i n R www•SSE WI Department of Commerce www.wisconsin.gov DEC 0 7 2007 Jim Doyle, Governor Jack L. Fischer, A.I.A., Secretary DEPARTMENT OF COMMUNITY DEVELOPMENT December 06, 2007 INSPECTION SERVICES DIVISION CUST ID No. 1046066 A ITN.: Buildings & Structures Building Inspector ADAM HEINDEL BUILDING INSPECTION EXCEL ENGINEERING CITY OF OSHKOSH 100 CAMELOT DRIVE POB 1130 FOND DU LAC WI 54935 OSHKOSH WI 54902 (Please forward a copy of this letter to the fire department conducting inspections of this project.) CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 12/06/2009 Identification Numbers Transaction ID No. 1487493 SITE Site ID No. 731939 Bros Koeller Please refer to both identification numbers, 312 N Koeller Drive above, in all correspondence with the agency. City of Oshkosh, 54902 FOR: Facility: 685322 BROS KOELLER 312 N KOELLER DRIVE OSHKOSH 54902 Tenant Name or Addn/Alt Description: Building additions (39' x 88' & 1' x 20' extensions) multi -tenant bldg Object Type: Building ICC Regulated Object ID No.: 1159275 Major Occupancy: Mercantile; Type IIB Metal Frame Unprotected class of construction; Addition - Alteration plan; 25,175 project sq ft; Unsprinklered; Occupancy: A -3 Other Assembly Uses, B Business, M Mercantile; Allowable area determined by: Fire Walls The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Submit • Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations, and appropriate fees are required to be submitted for review and approval prior to installation. The submitted HVAC plans shall match the approved building plans. Note as per Comm 2.10 installation of HVAC without approved plans could result in double fees. • Comm 61.30(3) Submit, prior to installation, one (1) set of properly signed and sealed metal building plans, a completed SB -118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison WI 53707 -7162. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submittal may be an additional $200. Reminders • Comm 61.30(3) This review does not include lighting. Comm 63.0001. Prior to installation, lighting plans and calculations shall be prepared in compliance with the code and properly signed and sealed. The plans shall be available at the job site as requested by the Department representative or local official. ADAM HEINDEL Page 2 12/6/2007 • Comm 61.31(2)(b) A copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. Changes to the approved plan must be submitted for review and approval. Failure to properly attach the approval and index page to plans that match the copy on file with the Department may result in enforcement action under ss. 101.02 or 443.13, Statutes. • The three items addressed in the attached letter from Excel Engineering Inc. dated December 6, 2007 must be met. Everybody shall be reminded that the masonry block to be used shall be from a eligible manufacturer bearing the UL Classification Marking. • Comm 61.36(1)(a) & (b) This approval will expire 2 years after the date of this letter if the building shell is not closed in within those 2 years. Also, this approval will expire 3 years after the date of this letter if the work covered by this approval is not completed and the building ready for occupancy within those 3 years. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional' full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 7 days prior to any earth disturbing activities. You will need to either file the NOI and an erosion control plan summary on -line at www.commerce.wi.gov /sb or submit a completed NOI form and either a plan summary or complete plan to us, with additional fees, or to the certified municipality. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ 1,090.00 00■.N.A.LZ). Fee Received $ 1,090.00 n Balance Due $ 0.00 Warren Douglas Erler Plan Reviewer , Integrated Services WiSMART code: 7648 (608)789 -4690 , Mon - Fri; 7:45 am - 4:30 pm warren.erler@wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014 , Monday,7:45A.M.- 4:30P.M. Excel Engineering Inc Randy Schmiedel, Bros LLC Proposed Rules: The Wisconsin Division of Safety & Buildings is in the process of adopting the 2006 International Code Council suite of building codes, including the International Existing Buildings Code, with a likely effective date of March 1, 2008. You may view or download the adopted draft of chs. Comm 61 -65 at www.commerce.vvigov/SB/SB-CodeD evelopment.html DEC -06 -2007 THU 08:32 AM EXCEL ENGINEERING FAX N0, 9209269801 P. 02 X CEL. ENGINEERING INC. • December.6, 2007 Mr. Warren Douglas Erler Wisconsin Departmept of Commerce 4003 N, Kinney, Coulee Road • • • La Crosse, WI.54601: #831 RE: Transaction ID No. 1487493 Dear Mr. Erler; • Attached you will find my responses to your December 5 review letter. • The 3 hour masonry wall will be constructed per UL Design No. 1.1904. I • have attached a copy of this design to this letter for your review. This information will also be forwarded to the contractor. • • . • The glazing. in! the AL10 frame has been corrected. Please see the • attached drawing. • Storage of recyclable will be provided in the new dumpster enclosure. Please see the attached site plan for location. If you have any questions, or require any additional information, please feel free to call me.' • Sincerely, ,' • EXCEL E INEERING • A i , A, SEED AP Arch! ect, Project Manager i . * ADAM d• * HEII•'1DEL 1\-g5 APPLE 110N H • • F:1Job Fites17o3820 Alliance.Deiralopment Koller StreeNcorreslWarren- 12QB07.doc 12/6/2007 100 CAMELOT DRIVE - FOND Au MC, WI 54935 . PHONE: (920) 926 -9800 FAX: (920) 926 -9801 Safety and Buildings PO BOX 7162 commerce.wi.gov MADISON WI 53707 -7162 TDD #: (608) 264 -8777 if isconsi n www•commerce.wi.gov /sb/ www.wisconsin.gov Department of Commerce Jim Doyle, Governor Jack L. Fischer, A.I.A., Secretary December 13, 2007 CUST ID No. 1046066 ATTIC• Buildings & Structures Inspector ADAM HEINDEL BUILDING INSPECTION EXCEL ENGINEERING CITY OF OSHKOSH 100 CAMELOT DRIVE POB 1130 FOND DU LAC WI 54935 OSHKOSH WI 54902 COMPONENT RECEIVED Identificati„nNumbrrs Transaction ID No. 1491182 SITE: Site ID No. 731939 Bros Koeller = ; Pease refer to both ide ication numbers, 312 N Koeller Drive above, m all correspondencetth the agency. City of Oshkosh, 54902 FOR: Facility: 685322 BROS KOELLER 312 N KOELLER DRIVE OSHKOSH 54902 Object Type: Metal Building Regulated Object ID No.: 1165495 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fire resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fire ratings have been employed. The submitted materials have not been reviewed by the Department for compliance with all applicable administrative rules. The department reserves the right to formally review the plans in the future if the department determines that such a review is warranted, and to order corrective actions with respect to the outcome of that review. A copy of the plan that is identical to the plan submitted for our file shall be available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan shall bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely, Fee Required $ 100.00 Fee Received $ 100.00 Balance Due $ 0.00 Joanne Koch License/Permit Program Associate , Integrated Services (608)264 -7623 , 07:45 - 4:30 joarme.koch@wisconsin.gov cc: John R Anderson, State Building Inspector, (715) 823 -2014, Monday, 7:45A.M.- 4:30P.M. Page 1 of 1 Dannhoff, Allyn J. From: Adam Heindel [adam.h @ExcelEngineer.com] Sent: Monday, January 28, 2008 2:12 PM To: Bob Albright Cc: adannhoff @ci.oshkosh.wi.us Subject: Bros Koeller Bob, I have received confirmation form Allyn that the approach we discussed on Friday will be acceptable. Provide 5/8" exterior gypsum board as a base layer under all EPS foam. Where there is no EPS, the polyisocyanurate insulation can be applied directly to the metal deck. If you have any questions, please feel free to call me. Thanks, Adam Heindel, AIA, LEED AP Architect, Project manager Excel Engineering, Inc. Office: (920) 926 -9800 Cell: (920) 904 -4300 Fax: (920) 926 -9801 Email: adam.h @excelengineer.com Web: www.excelengineer.com 1/28/2008 JUL -21 -2008 MON 11 54 AM EXCEL ENGINEERING FAX NO, 9209269801 P. 05 Buildings, HVAC Compliance Statement SBD -9720 703820 Bras. /Koeller Dr. Rev. This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of projects within buildings with total areas exceeding 50,000 cubic feet or greater and bleachers (Comm 50.10 /Comm 61.50). Failure to submit this form may result in penalties as specified in Comm 50.26 /Comm 61.23 and /or local ordinances. This farm must be submitted prior to the plan approval expiration date or another submittal may be required. General Instructions: Prior to the Initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and.signed form to; City of Oshkosh -Div. of Inspection Service 215 Church Ave., -PO Box 1130- Oshkosh, WI 54903 -1130 Note: If the review was done by the municipality, the compliance statement goes only to the municipal building inspector. Personal Information you provide may be used for secondary purposes [Privacy Law, s. 15.04 (1)(m)]. 1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. Transaction ID Number NIA Site Number NIA Site location (number & street) 312 N. Koeller St, I City ❑ Village (3 Town Of Oshkosh County of Winnebago 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary). Check those which apply: la Building Object ID# 1159275 0 HVAC Object ID# - ❑ Lighting Object ID# ❑ Partial Completion Description of Portion Completed A) 14 Statement of Substantial Compliance To the best of my knowledge, belief, and based on anslte observation, construction of the following building and/or HVAC Items applicable to this project have been completed in substantial compliance with the approved plans and specifications. BUILDING/LIGHTING ITEMS 1. Structural system including submittal and erection of all building 10. Exterior lighting & control requirements components (trusses, precast, metal building, etc.) 11. Interior lighting 8, control requirements 2. Fire protection systems (sprinklers, alarms, smoke detectors) 12. All conditions of lighting plan approval designed, Installed, and tested (Including forward flow on back flow and applicable variances devices) by appropriately registered professionals. 3. Shaft and stairway enclosure ❑ HVAC ITEMS q. Exits Including exit and directional lights 1. HVAC system including final test 5. Fire - resistive construction, enclosure of hazards, fire walls, labeled 2. All conditions of HVAC plan approval doors, class of construction, fire stopped penetrations and applicable variances 6. Sanitation system (toilets, sinks, drinking facilities) 7. earner - tree Including Comm 16 elevators and Ilfts 8. Energy envelope requirements 9. All conditions of building plan approval and applicable variances The following Items are not In compliance and must be addressed: B) ❑ Statement of Noncompliance Due to the following listed violations, this project is not ready for occupancy: C) ❑ Supervising Professional Withdrawn From Project (Use A or 13 above to Indicate project status as of this date.) D) ❑ Project Abandoned • 3. SUPERVISING PROFESSIONAL SIGNATURE FOR: o Building Q HVAC ❑ Lighting Adam Helndel, AIA, LED AP Date: 1 • ZI • o$ Name (please print or type) Phone 4 920- 926 -8800 Customer ID# N/A Signature .BD -9720 (ILn1/'Jilui) Page 1 of 1 Dannhoff, AIIyn J. From: Adam Heindel [adam.h @ExcelEngineer.com] Sent: Monday, September 15, 2008 12:00 PM To: Dannhoff, Allyn J. Cc: bobjr @rjalbright.com Subject: Koeller Street - Head of wall detail Attachments: incomingfax_ excelengineer _com_20080915_103504.pdf AIIyn, I have been in contact with 3M to come up with a head of wall joint for the existing 2 hour wall between Anytime Fitness and the old Buyers Guide space. 3M recommended the attached assembly be used. Since the joint is only accessible from one side, they recommended installing the joint material in the following order; mineral wool, FireDam Spray, mineral wool, FireDam Spray. The joint is to fill the entire thickness of the wall. If you have any questions, please feel free to call me. Thanks, Adam Heindel, AIA, LEED AP Architect, Project Manager EXCfl ENGINTEnING 100 Camelot Drive Fond du Lac, WI 54935 P: 920 j 926 1 9800 ext. 134 F: 920 1 926 1 9801 C: 920 1 904 1 4300 E: adam.h @excelengineer.com W: www.excelengineer.com Always a Better Plan 9/15/2008 ENGINEERING JUDGMENT FOR: 09/12/08 Fire Protection Products Dana Decker 3M FPP Sales / Upper Midwest and Chicago Region 1 St. Paul, MN 55144 Fax: (651) 735 -0277 Project: Oshkosh Retail Building Contractor: Adam Heindel Fire Stopping Category: Joints / Head of Wall Hourly Rating Requested/ Type: Smoke Seal / Smoke Seal Joint Type: Construction Maximum Joint Width: 1 in. Floor Assembly: Fluted Steel Deck/Roof Assembly Wall Assembly: Gypsum Wallboard Assembly Type of Movement Dynamic Special Conditions: Needs smoke seal on joint between gypsum wallboard assembly to metal roof deck. Write as smoke seal only with mineral wool and FD Spray 200 Application Details: To smoke seal the scenarios where a gypsum partitions abut the underside of a non -rated fluted metal deck, install in accordance with one of the following UL systems that applies to the field situation: HW -D -1059, HW- D-0478, HW -D -0447, HW- D-0205, HW -D -0101, HW -D -0031, HW -D -0029, HW -D -0020. 1. Due to the inclusion of a non -rated roof assembly, the obtainable rating of these scenarios is 'Smoke Seal'. 3M Fire Barrier Material: FireDam 200 Spray Based On: HW-D-1059, HW-D -0478, HW -D -0447, HW-D -0205, HW -D -0101, HW-D-0031, HW -D -0029, HW D -0020 At this time, 3M can only provide a smoke and draft seal rating for this application, From previous testing and experience, and if the 3M Fire Stopping Products are installed properly, the smoke and draft seal will receive an L rating of <1 CFM/Lin ft as per UL1479. Engineering Judgment Prepared By: Reviewed By: $ Mark Lund 524718 Technical Service Engineer c Dana Decker Adam Heindel Email: adam.h @excelengineer.com 3M Building and Commercial Services Division 3M Center, Building 207 - 1 S - 02 St. Paul, MN 55144 -1000 Page 1 of 1 .31 : T; .t • ‘ - 0 'j• ' ..';''' "1.51 ;.. :''. 7. . 1 • - • : ' t ':: - 4.-t.-...: ..: . .--_-4. :., :. ; 13 a . : ts; i ' -:. : . • F•'..41 •,... ': .:::'. I :3 , ' T. ,:; ." . : ''' .' • , ,:lit--: • -= - '.;' , 77 , 41 ,- 1 .i • .-i: .i-c.Y.,t: 4 - 4 -7 141. - , - -,_..-,. • • :- :: ;::'::'.. . , 4 i 1 - --• - • - .4 r - 4rio' Ti ...* . .• I -:;•'.. ' I : 4 : F : :.-. F. it I i..- ''. .4 -- •' ,..- _ 1 • • • • . .A,..7 - .",- .-' - • 4 • - -..• • -- i . •-"' 1. 4 v -17,...k:'.-...... tfi.- ,..-. _ ... .... .t 1. 4...?-t; • • .., ' -, t-..,:fd .t.: FireDarri Spray 200 , ..„ . ., ,,,.....,........._ ..,............ .....,. .,....„...„:„..,.. ......„ _ ,,,... „.,.... „.....„:...._ .........„ :.,.....,. ,: ' 1 ' : ..'-, R'L''''. I 1 i r , 1 . . .., - :-= Ali', a - ;:4-., . :,:. . . -- :IL .. .,- . • 4.9 . . ' :-•!:. 44 _ ; :.....: . -;.,..,. . . : ..„-,;:.. .,-,...„....„, .......-.---..t.,,., c .....?"-5.-_.,,,„,,,, . ..= .=. - .:..-,. .::..„- - .FT,. il,:.■ :',. , .-:',..". 4, •'''l ,'.. • • ' ,.. -`:----`; . =11 -: .. .,r- ' ; :=1 I ''' " : - '''....,'R''' 4.••••••:„,„.r-c '•:::: ..trg-. 4* :44,4,4„ ,, 7 4 " - .41 4 '; - ' • --- '11% '. - . - - 77 - Sq 4 ,.. -. • . • - -, a 4 F-•,,r,•, - - 2 - I 1 ' ''', , .7 - :. -- *A .f..:) .:T1 ;- ..:,‘„ -*-14....-.-- 4 -: :$ .- ' .5 "E'rE'.. -------..- ..-,', -si----e,, . .::,... . .,_ .,...,:,:::•.:,;,,:„!,„.-.---:,-IF„„y-----.70„.::N::= :Iv.. 5r,-..;-=1:7----:,--7.1:fi„1"-"''''' 4 7.1,;:i.-.5.4:-- , !:,:•• -_.. -- ... '' ':" '''''. iat- 1 1: 84 : 1 + : - ---'- v' 41:41'1*5='::.:-;. -- ": - := 1--- :: -"li ..e-it:' 2 3,43- - .---,---- -----.. -,--,...-Ir.:,,-"i--, / --J-2.. -•1 L.,.,_ i .,..y, - ... --. 7 .:::...Mge41,,,,,:,;;I:•.,?•:4":t. ,.:7 " - --Wg544.7.. .. i : • '.• 1 '' '-'''''''In't - ....;?-•----;.. :. .. . • •• ,. ... - ...;•_' 1 ' ••. '-..•••••.*2 • ka...1:44-4 - ,•-•,.-_,--,••••••--..------„,;-- , a......4....;g.=. ...,......„.. ..„....„•,,,.. _ • .. . •;:),$ ' -,..?:''' "•' ..--,...-..= ••::::,..*:,•;•:_:.-::.-1.....T. -, • -'-17--:,......4itezr.- i;',:i"+••--zals;.-7..- ACI.,..,94:;:,,;e•:-0,:':-..:-'.,2, ......._-_-. ,%•-..,mt . -.. ••••'Tt•••: "7"Nix - : _L-- , -■;;V:". ,...:„.- .w.:_.- - -54- - 4.7..:sv - L.. ::--. ':-..-, - ::: : :: --,..:.:.,,- --,, , .::' ...---:-...-_-.. _A 4 — 4.-- ... ...:,. -'';E:' ,-; - 4..,, . - ,.:: ..' - ' ''; 7 7; ' ,7 ',''.3:q .-. :•Z;:;. I- i t:F. , .1".. -=:- • -..-7:-.:7 -.4.7- - . .:--- .a.- - - -. -. - -' : .._. ..... . _ ._. , l,: 1 • :-!§::=. ' ..........- — - - _ . --,,,,•'-- '''. '.• T -: :-- ..._1...=; 6...1 i - .'!......_=-I-z7::::::::::----,-•-•,--"-::,-1,2,7 .::. ,-,-,., - - - - - — ------- ...t. -- - - -, : --,-. ..::::' , " =4 : 37,- Nff,..=-4.1._ - =.=-...2._•-i-,.- ',... :-; :: :* - N1:11 irr4 el P= i'd ..... -- 7 --,,..".:, .,, .....i. ,...., .,. rrer, d'.. • i.i • T 1' ...-:- ..t. '. _ , , , '..1:::4 -- -,-_--•--- .4.44. , ..-„4...--4_7-___4 -1: 1, 4 i - e• '.45 "1 ': 5 P e. N. Ei il R AI 1i ri, 1:•• §. i, :-. — - ------. . .. ' ,, :4:44:.- • , ... - S 4 . 14.,,c,._L o ._ •,....- 21::::.. ‘' 4 tt-- i--; it... . s'''• , - --= - --k_ 'ii ..- ... ,-,--.. -_,--:. ,-,,,,' - • ,, ... - - - - , -qf.::q..-- ..34 . 11 . x.. 1 re,,,ctili Sprki v: , : .....i .. ' --.,.,.- --- -•'1 4 ,:-4E .. .--,...• "•":" ' ' '' '.i.tk‘t." ..• -• __ j DI wr :3EN.AtiT ---.44,-Ait . .--:- - From 3M, the indush 4` y leader in :: - • , ;$,••-• , ..--,,- 0 .7 -, .!1,;---4 ,,.-Aitioam"."-Silltat "4.4 - - • - • "•,-.:,-: T• - "' . •••::-. .. 4 ..-- .::- . • _ . . . . fire protection technology: . - • .- • . • -:-; - 1..s.- ..--.----:•••:,.• - , a,„:-., . 111141t 440atIV ' .--=-- •- : "_.,"`" -2•:. ......,...y. • 3M'" FireDam'" Spray 200 is ideal for sealing building I 44 . joints, penetration seals and perimeter joints. - - • - • ....., ....„ . _. ... ....... _ . .: ,,..- ,.., ,.._ . Applied as a 1/8 inch (3 mm) thick coating with an - ... airless sprayer, this water-based coating dries in '.:•?.*!<,_ . ambient conditions to form a flexible seal wi is -7 ,41. .:::„:„, ci-:.:-.... • ,- : ,-.,.., ,..,- t,,,,„T....1: • ::: ' - ,-- 1. - . - - - :.- 5,?- 4 ?....r..... - .:-. -.. ...:;-% . ,.i.‘ . 7..,::4 - ..•• . compression/extension of up to +/- 25% of nominal = . • - joint width. 1' 7.54. . 7 -... ..... . . _ . ...-:„.„.. .. . , , .. . • .-, _ ..... —_ -- - - ---,-.--:_--::-..,,,,..-,• ..,4.,„ • --- '',+':=-......--,..,.:,-----.=-•-----W.=.77-=-1-7kiit.:-:---,...,1%5:0V.4.1t14 '...„..F 4 '• , - - '.•:''..7.1''''.": --.±-7 -_,....._.-- - : ... - ::::::::•:I - - .: -.. .e:t' : . : • :',.7. ''.7-77;7,---:=7:7.; : •::'.:'-` ='••• - - • • T - ' 7 .• , fri.L .- ., %-...,'.;'-:::'=::- - ::-.7.:::-. - - .„:::=.- , - --- 7..i: ..i....:5 3M FireDam Spray 200 meets IBC requirements and is '-?- - .':•--- ;'. • . ..::- -• . • . -:'•'..:- ..... '-'''''' - 7- - • :,' ---:"--. 4 tested for up to 4 hours. Its available from any 3M ' -,•• : ... _ .. -- - . --i;',. ... Authorized Fire Protection Products Distributor in five-gallon pails. t .F .:44- f - . 4 .:Ii:- E -"%lf;-: 7 :- - - .i . i:i • _...i.... ' - .."f=•: - - ' ''' !•',‘...'...','. ,... . .,-.7.-i...:-.. -ar iii - . , ..... ---- - ,-- :617. - --,-_-z.....-i..----.-- ' =';: ------- 7" -- . -- -- ‘ - - ---- ' — '5=7--------' - -a-4-*--z--,-,---,---::,.-::-;..%:-.-------;_-------:....-E--,-,:—.. c as • 4 R ■ , orying • Dries to a neutral gray color.i.iz . . • Highly elastic i _,...,,.. , --i--:. - :,..........,.. „ . - : - :- .---- -. 71- . 1 .. - - 0 -, --= - 7. 2 iim f-K- - -:7_,; , _ . _--- =_____ •-- i . --- ..:__ .„... 1. - --r.: : :::_ fir,...„ --_ _ ---- , ‘,....,,, • High-cling properties'help prevent sagging • Applied with conventlebel airless sprayers , . - --27-- --- --1--- - -'-- ",_-- ---- ''-'''--:*-7----'-'7Z-7.fr------r---L1-.....----2---t--,i1:-;,--=-:..--"t7-i—:--zi.!;._-_-- • Cleans easily with water' (no solvents required i • clhosion to most censtruction rnateriter....1, ili Super.oi a . . „.. .. . ,„ , . a .=-:::,,,, Ideal for head of wall, floor to wall ...:„...„,,,,..,.,,,..„,„..-.-..„ ...,. • Paintable when cureci . i ....,.. :.: --1-., and perimeter joints! . . 3M Fir eDam Tm Spray 200 aa03 wo ��a Ct� p S Sfrb, 411> 1 i C AS °ORATO APPROVED Listed FILL, VOID OR CAVITY SUBJECT TO THE Product Data Reference our Directory MATERIALS. FOR USE IN CONDMONS OF at 1R6.Opr.COm JOINT SYSTEMS AND APPROVAL AS A WALL 155654 2 THROUGH- PENETRATION & FLOOR PENETRATION FIRESTOP SYSTEMS SEE FIRE STOP WHEN UL DIRECTORY OF INSTALLED AS PRODUCTS CERTWIEO DESCRIBED IN THE FOR CANADA SEE UL FIRE CURRENT EDmON OF 1. Product Description 2. Applications RESISTANCE DIRECTORY 90G9 THE FM GUIDE OVAL GUIDE 9069 3M FireDamTm Spray 200 is Ideal for sealing building joints, sprayable water-based material, through penetration seals, and that dries to form a tough, perimeter joints. Helps limit the elastomeric coating. This material spread of noxious gas, smoke, and when used as part of an assembly water. Maintains the integrity of will firestop building joints, the fire -rated construction. perimeter joints (curtain wall), and through penetration seals. 3MTM FireDam Spray 200, when installed properly, will control the 3. Physical Properties transmission of fire, heat, and Units/ smoke before, during, and after Product Unit Volume Ctn. exposure to fire. FireDam 5 gallon 1155.0 cu. in. 1 Spray 200 (18.9 litre) (18926.9 cu. cm) 3MTM FlreDamT" Spray 200 Features 4. Specifications • Superior adhesion to most construction materials Product • Highly elastic -- maintains The coating is tested and listed by independent test agencies including performance with +/- 25% joint UL and ITS Omega Point Laboratories. The coating complies with the movement requirements of IBC, BOCA, ICBO, SBCCI, and NFPA Code 4101. • Broad range of applications- - extensive portfolio of tested and Building Joints: Have been fire tested and evaluated under the pass/fail listed building and criteria of ASTM E 1966 and UL 2079 at maximum extended joint width. perimeter joint systems • Applied with conventional Perimeter Joints: Have been fire tested and evaulated under the airless spray equipment pass/fail criteria of ASTM E2307 at maximum extended joint width. • Robust job site formula Penetration Seals: Are capable of passing ASTM E 814/UL 1479 - Freeze/thaw resistant Standard Method for Through - Penetration Firestops up to 2 hours fire - Uniform seal formation in resistance rating. hot and cold drying conditions Typically Specified Divisions • Low sag, thick coating build Division 7 Thermal and Moisture Protection properties- -stays where it's 07840 Firestopping sprayed 07842 Fire Resistive Joint Systems • Paintable • Easy water clean -up B. Firestopping Properties 5. Performance A. Typical Physical Properties Building Joints: Underwriters Laboratories Systems: HWD0020, HWD0021, HWD0022, HWD0023, HWD0029, Color: Gray HWD0030, HW00031, HWD0038, HWD0040, HWD0101, Non Volatile Content: Gray HWD0122, HWD0123, HWD0192, HWD0248, HWD0265, Viscosity 40,000 cps HWD0376, HWD0379, HWD0384, HWD0385, HWD1010, HWD1059, FFD0002, FFD1042, FFD0014, FWD0004, Coverage *: 12.8 sq. ft. /gallon (0.31 sq. m/litre) FWD0011, FWD1040 Flash Point: None ASTM E 84: Flame Spread: < 25 Penetration Seals: Underwriters Laboratories System: Smoke Development: < 50 CAJ1275, CAJ1275, CAJ8106, WL8033, WL8034 Dry Time: < 4 hrs tack - free Perimeter Joints: Omega Point Laboratories 670°F (21°C)/56% R.H. 24 hrs fully dry CEJ113P, CEJ114P, CEJ115P, CEJ116P, CEJ119P, CEP120, The coverage rate listed Is calculated coverage based on 1/8 In. (3 mm) thick wet coating. CEJ121 P, CEJ122P, CEJ123P, CEJ124P, CEJ125P, CEJ126P, CEJ158P, CEJ159P CEJ160P, CEJ161P, CEJ162P, CEJ163P, CEJ164P, CEJ165P, CEJ166P, CEJ167P, CEJ168P, CEJ169P, CEJ234P, CEJ238P, CEJ266P, CEJ267P, CEJ2B8P, CEJ289P, C. Firestopping Code Requirements CEJ311P, CEJ312P, CEJ313P CEJ35OP, CEJ370P' ICBO Uniform SBCCI Standard BOCA Basic/National Building Code NFPA Life Safety Building Code Building Code (1996 Edition) Code 101 (2003 Edition) (1997 Edition) (2006 Edition) 702 104.2.4 702.0 709.7 8.3.5 DEFINITIONS PLANS MUST SHOW HOW REVISED AND JOINTS PENETRATIONS INTEGRITY IS EXPANDED DEFINITIONS 706 MAINTAINED FOR FOR PENETRATIONS 711.0 8.3.6 CONSTRUCTION JOINTS ASSEMBLIES AND JOINTS FIRE PARTITIONS JOINTS 708 PENETRATED 7 7 FRAME 703.1 711.6 8.4.4 WOOD CO OD FRAME 202 CONSTRUCTION PENETRATIONS - REFERS PENETRATIONS CONSTOCKING DEFINITIONS DOCUMENTS SHALL TO 714 INDICATE DETAILS AND 8.4.5 709 705.3 MATERIALS FOR 711.7 JOINTS WALL & PARTITION WOOD FRAME PROVIDING RATINGS AT JOINTS - REFER TO 709.7 PENETRATION CONSTRUCTION JOINTS AND 8.5.6 PROTECTION FIREBLOCKING PENETRATIONS 713.0 PENETRATIONS FLOOR/CEILING AND 709.3.2.2 705.3.1.5 703.1.1 ROOF /CEILING 8.5.7 CURTAIN WALL GAP CURTAIN WALL GAP PENETRATIONS AND ASSEMBLIES JOINTS JOINTS SHALL NOT BE 710 705.4 (GENERAL) CONCEALED FROM 713.2 FLOOR/CEILING OR PENETRATIONS OF FIRE VIEW BEFORE CURTAIN WALL GAP ROOF/CEILING RATED ASSEMBLIES INSPECTION PENETRATION 713.4 PROTECTION 705.5 (WALLS) 703.2 PENETRATIONS - REFERS NFPA 711.3 BUILDINGS FOR MORE TO 714 SHAFT ALTERNATIVE 705.6 (FLOORS) THAN TWO STORIES Code 70 NEC SHALL INDICATE 713.5 National 714 705.7 ALL PENETRATIONS JOINTS - REFERS TO THROUGH - PENETRATION FIRE RESISTANT JOINT 709.7 Electric Code FIRESTOPS F &T SYSTEMS 704.1.1 REQUIREMENTS SUFFICIENT DATA 714.0 300 -21 FIRESTOPPING SHALL BE AVAILABLE PENETRATIONS - ALL UBC STANDARD 7 -1 International TO JUSTIFY UNTESTED REQUIREMENTS EQUIVALENT TO Building Code MATERIALS USED FOR (GENERAL) ASTM E 119 (2003 Edition) RATINGS ATION OF FIRE 7141 THROUGH 714.1.6.2 One UBC STANDARD 7 -5 WALL ASSEMBLIES One and Two EQUIVALENT TO 702 707.0 Family Dwelling ASTM E 814 DEFINITIONS FIRE WALLS AND 714.2 THROUGH 714.2.6.5 Code PARTY WALLS FLOOR /CEILING AND 712 707.10 ASSEMBLIES ROOF/CEILING (1995 Edition) NFPA 5000 PENETRATIONS PENETRATIONS - 602.7 (2006 Edition) 713 REFERS TO 714 714.3 THROUGH 714.3.2 FIRESTOPPING FIRE RESISTANT JOINT NONRATED ASSEMBLIES ( FIREBLOCKING IN OTHER 8.8 SYSTEMS 707.8 MODEL CODES) PENETRATIONS JOINTS - REFERS TO 721.0 8.9 713.3 709.7 FIREBLOCKING AND JOINTS EXTERIOR CURTAIN 709.0 DRAFTSTOPPING WALL/FLOOR FIRE SEPARATION 8.9.3 INTERSECTION ASSEMBLIES EXTERIOR CURTAIN WALLS AND THE 709.6 PERIMETER JOINT PENETRATIONS - REFER TO 714 6. Installation Techniques (4°C) and 90 °F (32°C). 3MT"" dispensing 3M FireDanfm Spray FireDamTM Spray 200 can be 200 and achieving the thickness Shown is an example of a UL applied when the ambient air and coverage necessary to comply tested and listed system for 3M°4 temperature is 10°F ( -12°C) or with the tested systems for the FireDamTM Spray 200. The higher. Note: ft is recommended product. The equipment appropriate tested and listed that the pails of product remain mentioned is not an entire list of system must be used for each in heated storage at 70 °F (21°C) the pumps capable of delivering application. Additional details are prior to spraying material in 3M° FireDamTM Spray 200 but a available through your 3M conditions below 40 °F (4 °C). sample of those known to be authorized Fire Protection Products capable of accomplishing the Distributor or sales Mel FireDamTM Spray 200 can desired results. representative. be applied to surfaces that are 10 °F ( -12 °C) providing that the General Equipment Parameters 1. Surface Preparation: Surfaces surfaces are frost free, clean, must be frost free, clean, dry dry and dust free. Flow Output: 0.6 gpm minimum and dust free. Liquid Pressure: 2000 psi minimum The curing (evaporating of Recommended Tip Size: No. 419 water) of the 3MN FireDamTM (8 in. fan with 0.019 orifice 2. Insulation: Cut minimum 4 Ib. )can be density mineral wool to the 200 is affected by the ambient changed based on application contour of the joint adding 25% temperature and humidity. The conditions to each dimension so that the lower the temperatures and the Motor Size: Greater than or equal mineral wool can be tightly higher the humidity the slower to 0.75 horsepower packed into the joint. The the product will dry. At 70 °F mineral wool should be flush (21 °C) and 50% R.H. a 1/8 in. Recommended Equipment with the face of the wall. thick wet coating is fully dried in Wagner: SprayTECH® EP2355, 24 hours. Note: At temperatures EP2400 and EP2510 3. Coating: Apply the 3M0, below 32°F (0°C) no drying of Grace: Ultra® Max 695, 795, FireDamTM Spray 200 using an the products will occur until the 1095 and 1595 airless sprayer to the joint temperature of the installed Titan: 840ix and 1140ix overlapping onto the wall and product is above 32 °F (0°C). floor a minimum 1/2 in. (13 mm). Equipment Start -up A minimum 1/8 in. (3 mm) 7 Spray Equipment If the spray equipment has been wet coating should be applied used previously and has wash of a over the mineral wool and These procedures are intended to previous product, then purge the substrates. 3MT"' FireDamTM inform and users of the equipment machine, hoses, and gun prior to Spray 200 must be applied at a requirements for properly spraying - do this as follows: temperature between 40 °F • Have a 5- gallon pail filled with 3MT FireDamTM Spray 200 five (5) gallons of clean water. 2 hr. Gypsum Wallboard Fluted Steel Deck This will be needed for clean - up at the end of the application. Item #1 Fluted steel Deck • Turn on pump in prime (re- circulating mode). The pump 3.0" should have a large and small Item 12 d tube. The large tube is a primary material pick -up tube, and small tube is the 1 °" h re- circulating tube. Joint Item #3 J---- • With pump in prime mode, place large pick -up tube in pail of waba d clean water, leaving small Item #1: 4 Ib. density mineral wool re- circulating tube out of pail. Cut the shape of the flutes • As pump primes, water will be item #2: 4 ib. density mineral woo! pushed out of system -- pump cut to the contour of the this water into another container. flutes and the loint Continue to do this until a Item #3: Minimum 1/8" (0.125`) complete flow of clean water wet coating of 3M solution is attained. FireDam Spray 200 • Drop re- circulating tube into pail of clean water solution. • Change pump from prime to gallon pail. Place the clean maintenance and storage. spray mode. Hit the trigger of water solution next to the pump °SprayTECH' is a trademark of Wagner gun and hold open until clean and drop the large pick -up tube 'Ultra is a trademark of Greco water solution only comes out. into the solution, while holding • Next turn pump back to the small re- circulating tube 8. Maintenance re- circulating mode and drop away from the clean water large pick -up tube in pail of solution. 3MTM FireDamTM Spray 200 is 3MTM FireDamTM Spray 200, • As machine comes to prime (out stable under normal storage while holding the small of small tube) 3MTM FireDamTM conditions. The product has a 12 re- circulating tube aside in Spray 200 will come out first, month shelf life when stored at another empty small pail or cup. then a combination of 3MTM recommended temperature in the • As pump primes, you will pump FireDamTM Spray 200 and clean original, unopened container. clean water solution; then a water solution, then finally just Store at 40 °F to 90 °F (4°C to combination of 3MTM FireDamTM the cleaning solution and water. 32 °C) for maximum shelf life. Spray 200 and clean water • Now drop small tube in the pail Normal stock and stock rotation solution and finally just 3MTM of the water solution and allow are recommended. Higher FireDamTM Spray 200. machine to re- circulate for a temperatures can , redupe shelf life. • Change pump to spray mode couple of minutes. and hit spray trigger. As before, • Now change pump from prime 9° Purchase Information hold gun open until you have (re- circulating) mode to spray just 3MTM FireDamTM Spray 200 mode and immediately hit the 3M T FireDam TM Spray 200 is coming out. trigger on spray gun. available from 3M Authorized Fire • Then equipment is ready to • 3MTM FireDamTM Spray 200 will Protection Distributors. For spray. come out first then a combine- information on where to buy, go to tion of 3MTM FireDamTM Spray www 3m com/firestop or call (800) Equipment Clean -up /Shutdown 200 and clean water solution 328 -1687. To clean-up the gun, hoses, and and finally just clean water spray machine a couple of clean solution. plastic 5- gallon pails, a tooth -brush • Run the entire 5 gallons of water 10. Safe Handling or other similar brush will be liquid through the machine. Information needed. • if the pump will not be used for Consult Material Safety Data • First, place pump in a couple of days, an additional Sheet prior to handling and re- circulating mode and remove five (5) gallons of clean water disposing of 3MTM FireDamTM both tubes from pail of 3MTM solution needs to be circulated Spray 200. FireDamTM' Spray 200. Using through the machine for ten (10) paper towel, wipe any excess minutes. spray off the outside of the pick- • Use a toothbrush to clean -up up and re- circulating tube. the gun and spray tip. • Have a minimum five (5) gallons • Follow pump manufacturer's of clean water in a five (5) recommendations for pump Warranty and Limited Remedy This product will be free from detects in material and manufacture for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. User Is responsible for determining whether the 3M product is fa for a particular purpose and suitable for user's method of application. If this 3M product is proved b be defensive within the wananty period stated above, your exclusive remedy and 3M's sole obligation shall be, at 3M's option, 10 replace or repair the 9M product or refund the purchase price of the 3M product. LinallaticantilablIty Except where prohibited by law, 3M will not be liable far any loss or damage arising from the use of this 9M product, whether direct, Indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3111, Building and Commercial Services Division 3M and FireDam are registered trademarks of 3M Company. 3M Center, Building 223 -2S -24 St. Paul, MN 55144 -1000 Phone 800 -328 -1687 Fax 888 - 362-2737 Printed in U.S.A. Bolger 7010958 www.3m.com/firestop oat 2008 98-0213- 4340 -9 Page 1 of 2 Dannhoff, Allyn J. From: Dannhoff, Allyn J. Sent: Monday, December 01, 2008 1:30 PM To: 'Adam Heindel' Subject: RE: Koeller Street Retail Building Thank you for the clarification, I believe we went down the same path when the other wall was done. My apologies. Please proceed and ask someone to let me know when it is done so I can inspect and close this file. From: Adam Heindel [mailto:adam.h @ExcelEngineer.com] Sent: Monday, December 01, 2008 8:42 AM To: Dannhoff, Allyn 3. Subject: Re: Koeller Street Retail Building Allyn, Per the fire stop manufacturer, they cannot rate a joint between a rated wall and an unrated roof assembly. The joint will stay in place only as long as the roof assembly is in place. Therefore, they can only rate the joint as a smoke seal in cases like this. Please call me if you would like to discuss. Thanks Adam Heindel Architect, Project Manager Excel Engineering, Inc. From: Dannhoff, Allyn J. To: Adam Heindel Sent: Mon Dec 01 08:02:46 2008 Subject: RE: Koeller Street Retail Building Sorry if I did not respond earlier. The attachment lists this as a Smoke Seal, not as a rated head of wall joint. The intent is to complete the rated wall to the underside of the roof deck. Is this the same joint used for the opposite wall of the Anytime fitness? From: Adam Heindel [ mailto :adam.h @ExcelEngineer.com] Sent: Wednesday, November 26, 2008 12:56 PM To: Dannhoff, Allyn 3. Subject: Koeller Street Retail Building Allyn, Back in September, I emailed this document to you for the proper top of wall treatment for the existing rated wall between Anytime Fitness and the old Buyers Guide space. I don't think that I ever received a response back on whether or not this would be acceptable. Please get back to me so that the contractor can get the work completed. Thanks, Adam Heindel, AIA, LEED AP Architect, Project Manager EXCEL ENGINEERING. 100 Camelot Drive Fond du Lac, WI 54935 P: 920 1 926 1 9800 ext. 134 F: 920 1926 ( 9801 12/1/2008 Page 2 of 2 C: 920 1 904 1 4300 E: adam.h @excelengineer.com W: www.excelengineer.com Always a Better Plan From: mwlund @mmm.com [mailto:mwlund @mmm.com] Sent: Friday, September 12, 2008 10:32 AM To: dadecker @mmm.com Cc: Adam Heindel Subject: 524718.pdf Oshkosh Retail Building Regards, Mark Lund, PE Technical Service Engineer 3M Building & Commercial Services Division 3M Fire Protection Products mwlund @mmm.com 12/1/2008