Loading...
HomeMy WebLinkAbout2007-Project Closed Job Address 351 S WASHBURN ST Building Permit Work Card Permit Number 0122306 Create Date 10/20/2006 Owner WALMART REAL ESTATE BUSINESS TRUST Contractor HUNZINGER CONSTRUCTION CO Category 223 - Alteration Offices, Banks, Professional Occupany Permit Not Required Flood Plain Height Permit Use/Nature Dept. Store - Convert Family Center into Aurora Quick Care. of Work Plan V7-103-1006 Class of Const: HVAC Contr Plumbing Contr Electric Contr Inspections: Date 11/8/2006 Type Rough In Inspector Allyn Dannhoff ro' Walmart Aumm Q"'e' Ca', DatelTime requested: 11/7/2006 07: 18 AM Notice Type: Ready DatelTime: 11/7/2006 07:18 AM Access: I Requested By: Dan wI Hunsinger Const phone Number: 414-303-4837 o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid no time -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - - - - - -- - - - - - - - - - - - - - - - - - - --- - -.. - -- - - - - - - - -- - - - - - -- - - - - - - - - - '--- - - - -- - - - - -- -.;. - - -' -- - - - - - - - - _:... - - - - - - - --- Date 11/8/2006 Type Inspector Allyn Dannhoff no time .Request Line / Ready for a stud inspection. 11/8/2006 - no time - called Dan at Hunzifler and told him to proceed only after any electrical br plumbing has been approved. DatelTime requested: 11/7/2006 11 :31 PM Notice Type: Access: IPlastic on front of unit Requested By: HUNZINGER CONSTRUCTION CO - Dan o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready DatelTime: 11/7/2006 11:31 PM Phone Number: (414) 303-4837 - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - -- - - - - - - - -- -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - --- - - - - ---- - - - - - - - - - - - - --- - - - - -- - - - -- - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - --- - - - - -- - -- Date 12/31/2007 Type Final Inspector Allyn Dannhoff not approved Request ine. CLOSE FILE - HVAC Plan approval and potential return air and air contaminant issues have not been documented for compliance. DatelTime requested: 12/7/2006 08:42 AM Notice Type: Access: I Requested By: HUNZINGER CONSTRUCTION CO - Dan o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready DatelTime: 12/8/2006 Phone Number: 414-303-4837 - - - - - - - - - - - - - - - - - - -- - - - - -- -- - - - - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - -- -- - - - - -- - - - - - - --- - --.- - - - - - --- - -.. - - - - - - - - - -- - - - - - -- - - - - - - - - - --- - - - -- - - - - - -- - -- - - - - - - - - - - - - - - - -- - - - - -- Page 1 of 1 Electric Permit Work Card Job Address 351 S WASHBURN ST Permit Number 122469 Create Date 11/6/2006 Owner WALMART REAL ESTATE BUSINESS TRUS Service b New 0 ChangeO Temp . N/A Volts Circuits 10 Contractor VENTURE ELECTRICAL CONTRACTOR: I Type 0 Overhead 0 Underground . N/A Luminaires 18 Amps UsefNature of Work Switches 7 Receptacles 19 ~43 - Commercial-Addition/Remodels Dept. Store - Convert Family'Center into Aurora Quick Care. Value $16,000.00 , Inspections: Date 11/09/2006 Type Rough In Inspector Kevin Benner approved w/cond. he stubs were not install led from the electrical panel and 3 devices in the walls. All 9ther installations are approved. DatelTime requested: 11/08/2006 01 :49 PM Access: Notice Type: Ready DatelTime: 11/08/2006 01 :49 PM Requested by: VENTURE ELECTRICAL CONTRACTORS o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Phofle Number: 414-416-1658 Darryl - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~ - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -- -- - - - - - -- - - - - -... --'- - - - - - - --.- - - - -- - - - - - -- - - - - - -- - - - -- - - - - - - - - - - -- -.- - - - -.- - -- Date 12/04/2006 Type Abv Ceiling Inspector Kevin Benner not approved DatelTime requested: 12/01/2006 01:03 PM Access: Notice Type: FC Ready DatelTime: 12/04/2006 00:00 AM Requested by: VENTURE ELECTRICAL CONTRACTORS o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Phone Number: 414-416-1658 Darryl ----- - - -- - ---- --- - ------.- ----- - - - ---- - - - ----- - - - ---- -- - - - - ------ - - - - ----- ---- -- - ----- -- ---- - - - ------10 - -------_ ____ _ _ _ ____ _ _ _ _________ _ _____._ ____._ _ _ _ ____ ____ Date 12/05/2006 Type Consultation Inspector Kevin Benner Meet the HVAC contractor on site to review the VAV / Duct heater installation to corr~ct Work Space violation. he easr unit is oksy, the west unit is to be turned 180 degrees and a temporary wall support to be removed as well as CL wiring to be relocated that is secured to the before mentioned wall support. This was reviewed with Mark from Total Comfort and Darryl from Venture Electric i DatelTime requested: 12/05/2006 07:56 AM Access: Notice Type: Ready DatelTime: 12/05/200610:00 AM Requested by: Total Comfort HVAC Contractor Mark o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Phone Number: -- --- ------ -- ------ - - - - ---- -- - ---- - - - ---- - - - ----- - -- - - ------ ---- ---- - --------------- ---- - - - ---- - --- -._- ---- ---- - - - ------ ------ -- ----- ---- -- ----- - ----------- Date 12/08/2006 Type Final Inspector Kevin Benner not approved breaker loks required for the water heater disconnects and the circuit breakers shall bl;l clearly identified as to its purpose. Reviewed with Darryl from the E.C. DatelTime requested: 12/07/2006 01:57 PM Access: Notice Type: Ready DatelTime: 12/08/2006 11 :30 AM Requested by: VENTURE ELECTRICAL CONTRACTORS o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Pho~e Number: 414-416-1658 Darryl - - - - -- - - - - - - - - -- - -.- - - - -- - - - - - - - - - - - --- - - - - - - -- - - - - - - - -- - - - - - - -- -- - - - - - - -- - - - - - - - - - - - - - - - - --- - - - - -- - - -'- - - - - -- - - - - - -- - - - - --- - - - - --- - - -- - - - - - - - - - - --- - - - - - - - - -- HVAC Permit Work Card Job Address 351 S WASHBURN ST . Owner WALMART REAL ESTATE BUSINESS TRl Fuel U Gas I U Oil I U Electric I U Solar U Solid I Value System 0 New I 0 Replace I 0 Other U Forced Air I U Radiant I U Steam I U AlC I U Vent U Electric I U Hot Water I U Suppl. I U Con. Burner I Chimney Type 0 Chimney A 0 Chimney B 0 Direct Vent Use/Nature ICOMM/ReVise existing ductwork. Add (2) duct heaters and toilet exhaust fan. of Work I I Inspections: Permit Number 122449 Create Date 11/06/2006 Contractor TOTAL COMFORT OF WISCONSIN INC $6,200.00 I I . Not Applicable l I Date 12/31/2007 Type Final Inspector Allyn Dannhoff not approved HVAC Plan approval and potential return air and air contaminant issues have not been documented for compliance. DatelTime requested: Access: I Requested By: o Reinspect Fee 0 Fee Waived Notice Type: Ready DatelTime: Phone Number: o Reinspect Fee Paid - - - - -- - - - - - - -- - - - - - - - -- - - - - - - -- - - - - - - --- - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - - - - - - - - - - - - - - -. -- - - - - --- - - - - - - - - - - - - - -- - - - - --- - - - - - - - - - - - - - - - -- - - - - - - - - - -- - - -- Plumbing Permit Work Card Job Address 351 S WASHBURN ST Permit Number 122460 Create Date 11/08/2006 Owner WALMART REAL ESTATE BUSINESS TRU Contractor LOUIS SCHMITT PLUMBING Category 440 - Industrial-Interior Plan Value $12,600.00 Bathtub Shower Water Softner Wait. St. Shamp Sink Coffee Maker - - - - - - Whirlpool Floor Drain Local Waste Ice Chest - FlrlWst Sink - Int Grease Trap - - - - Lavatory 1 Lndry Tray Clothes Wshr Exam Sink 2 Catch Basin Ext Grease Trap - - - - -- Toilet 1 Disposal - Bidet Sculry Sink - Wash Ftn - RPZ Valve - - - Res. Sink Dishwasher Beer Tap Hand Sink - Urinal - Eye Wash Statn - - - - Bar Sink Sump Pump - Lab Sink Plaster Sink - Standp Ree - Wtr Sewer Mtrs - - - Water Heater 3 Classrm Sink - Sterilizer Surgeons Sink - lee Maker - Deduct Meters - - - Site Drain - Breakrm Sink - Dip Well - F Prep Sink - Gar Drain - Wtr Usage Mtrs - Roof Drain - Ejector/Grind - Drink Ftn - Serv Sink - Soda Disp - Misc. - Fixtures Use/Nature New Aurora Clinic addition in Wal-Mart/lnterior Plumbing with point-of-use electric water heaters. of Work Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Inspections for Work Card 89483 Date 11/9/2006 Type Underground Rough Ir Inspector Paul Wolf approved " DatelTime requested: 11/8/200601 :32 PM Noti.ce Type: Telephone Number: Access: I Ready DatelTime: 11/8/2006 01 :32 PM Requested By: LOUIS SCHMITT PLUMBING o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid - -- - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - ... - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - --- - - - - - - - - - --.... - - - - - - - - - - - - - - - - - - - - - - - - - --- - -.. - - - - - - - - - - - - - --.- - - - - -- - - - -- - - - - - -- - - - -.. --' - - - - - -- - - - - --- Date 12/8/2006 Type Final Inspector Paul Wolf not approved No access, left card. DatelTime requested: 12/7/200601:20 PM Notice Type: Telephone Number: Access: I Ready DatelTime: 12/7/2006 01:20 PM Requested By: LOUIS SCHMITT PLUMBING o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - -- - - - - - - -- - - -- - -- - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - ..- - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - -- - - - -- Date 12/11/2006 Type Re Final Inspector Paul Wolf approved DatelTime requested: 12/12/200E08:43 AM Notice Type: Telephone Number: Access: I Ready DatelTime: 12/12/200( 08:43 AM Requested By: LOUIS SCHMITT PLUMBING o ReinspectFee 0 Fee Waived D Reinspect Fee Paid - --- - - - - - - -- - - - - - - - -- - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - - - - - -- - - - - - - - - - - - - - -- - - - --- - - - - - - - - - - - - - - -- - - - - - -- - - - - - -- - - - -- - -- ""'" j commerce.wi.gov ~i!~900!Jen Safety and Buildings 141 NW BARSTOW ST FL4TH WAUKESHA WI 53188-3789 TOO #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary September 22, 2006 CUST ID No. 911436 A TTN: Buildings & Structures Inspector CURTIS BAER THE ZIMMERMAN DESIGN GROUP 7707 HARWOOD AVE MILWAUKEE WI 53213 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 09/22/2007 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 SITE: Walmart Supercenter #1430 351 S Washburn St City of Oshkosh, 54901 ; Fire Dept ID: 7003 FOR: Facility: 675585 W ALMART SUPERCENTER #1430 - AURORA QUICK CARE 351 S WASHBURN ST OSHKOSH 54901 Tenant Name or Addu/Alt Description: AURORA QUICK CARE Object Type: Building ICC Regulated Object ID No.: 1096400 Major Occupancy: Mercantile; Type HIB Exterior Noncombustible Unprotected class of construction; Alteration plan; 472 project sq ft; Occupancy: M Mercantile Tenant Name or Addu/Alt Description: AURORA QUICK CARE Object Type: HV AC ICC System Regulated Object ID No.: 1099018 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Items · The submitted plans have been reviewed and conditionally approved pending receipt of the fees indicated. A copy of this letter has been sent to all appropriate parties. The designer has been informed that the conditionally approved plans will remain on hold within the Department until the required fees have been paid. r CURTIS BAER Page 2 9/22/2006 . No permits shall be released, nor work commenced onthis project until plans are released and can be provided on-site. If the conditionally approved plans are in the field, the inspection group can safely assume all required fees have been appropriately paid. Failure to pay within 30 working days will result in a denial. Submit . Approval of Plumbing Plans is not included with this review. Submittal of Plumbing Plans and Calculations in compliance with mc 2901.1 and Comm 81 to 87 may be required depending on the number of fixtures and type of facility. Approval of Plumbing Plans, if required, shall be obtained prior to commencing construction. A copy ofthe approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of th~ Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. If this construction project will disturb one or more acres of land, an Erosion Control No~ice of Intent (NOI) shall be filed with the department 14 days prior to any earth disturbing activities. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ Fee Received $ Balance Due $ 450.00 360.00 90.00 Keith Glaunert, P.E. Fire Protection Engineer, Integrated Services (262)548-8604, M - F 7:30 AM - 4:00 PM keith.glaunert@wisconsin.gov Make Checks Payable To Commerce. cc: Peter R Ochs, State Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M. Wal-Mart Real Estate Business Trust John Rydzewski, Aurora Health Care Ventures ~. '. Dannhoff, Allyn J. From: Sent: To: Cc: Subject: Dannhoff, Allyn J. Wednesday, November 22,200610:27 AM 'joe.ward@wal-mart.com' 'slemke@hunzinger.com'; 'STORE-MGR.s01430@STORES.US.wal-mart.com' RE: STORE 1430, Oshkosh, WI Good Morning Mr. Ward; I was advised by Shem Lemke of Hunzinger that you would be the most appropriate person to contact about the following issue: I was contacted by a local HVAC contractor that had been contacted by your company about modifying an existing HVAC system to address the odor issue created by the Nail Salon and is affecting air quality for the adjacent Aurora Quick Care Center at the Oshkosh, Wisconsin Wal-Mart. Please note this information has revealed there are Code Issues to be corrected at this site. Per the HVAC Plans for the Quick Care Center, these two spaces share one HVAC System and the return air duct for this system is located in the Nail Salon. As a result the return air is transferring the odors from the Nail Salon into the adjacent Quick Care Center. Please note this situation creates the following violations (or potential violations) of the State of Wisconsin Building & HVAC Code: 1. The Nail Salon, per COMM table 64.0403, would be classified as a Beauty Salon and as such is required to provide 1/2 cfm per s.f. of floor area of exhaust (to be exhausted directly to the outdoors.) It is unknown if this has been provided. 2. Comm 64.0403 3. Where mechanical exhaust is required by Table 64.0403, recirculation of air from such spaces shall be prohibited. All air supplied to such spaces shall be exhausted, including any air in excess of that required by Table 64.0403. In layman's terms, no air from the Nail Salon (because it is contaminated/odored) can be introduced into other areas of this building. As a result, revised HVAC Plans shall be required to be submitted to the State for review and approval to address this design oversight. Please note, the present State Approved Plans did not identify that a Nail Salon existed and would be sharing the HVAC system with the Quick Care Center. Please advise me what steps will be taken to comply and the time frame that is anticipated in complying. If you have any questions, please call me at 920-236-5045. Sincerely; Allyn Dannhoff Director of Inspection Services City of Oshkosh -----Original Message----- From: slemke@hunzinger.com [mailto:slemke@hunzinger.com] 1 .. Sent: Wednesday, November 22, 2006 9:36 AM To: adannhoff@ci.oshkosh.wi.us Subject: FW: STORE 1430, Oshkosh, Wl Shem Lemke Project Manager Hunzinger Construction Company 21100 Enterprise Avenue Brookfield, WI 53045 262.780.9117 262.797.0474 fax ----- Forwarded by Shem Lemke/hunzinger on 11/22/2006 09:34 AM _____ "Joe Ward" <Joe.Ward@wal-mar To: "Kerr, Matthew" <Matthew.Kerr@zdg.com> t.com> cc: <john.rydzewSki@aurora.org>, <slemke@hunzinger.com>, "Baer, Curt G." <curt.baer@zdg.com>, "Jansen, Lisa C" <lisa.jansen@ZDG.com>, "Denise Wes!;:" 11/16/2006 08:07 <Denise.west@wal-mart.com> Oshkosh, WI AM Subject: FW: STORE 1430, Matthew, Please note that this is being addressed in this matter. Please monitor the situation and let me know if you need more help. Thanks, Joe Ward Project Manager Income Development lA, IL, IN, MI, MN, MO, WI Wal-Mart Stores Inc. P: 479-277-0180 F: 479-204-2263 joe.ward@wal-mart.com -----Original Message----- From: Paul Humphreys Sent: Thursday, November 16, 2006 7:54 AM To: 01430-US-OFFICE ASSOCi 01430-US-STORE MGRi 01430-US-STORE CO MGR Cc: Joe Wardi 'Linda Fade' Subject: FW: STORE 1430, Oshkosh, WI Importance: High Joe Ward with Branded foods brought the odor issue to our attention. 2 ~ Rci is needing to add an extension to the vent pipe so odors cannot come into the medic area. -----Original Message----- From: Joe Ward Sent: Monday, November 06, 2006 4:54 PM To: 'Kerr, Matthew'; Paul Humphreys Cc: jOhn.rydzewski@aurora.org; slemke@hunzinger.com; Baer, Curt G.; Jansen, Lisa C; Denise West; Sharon Gregory Subject: RE: Quick Care - HVAC Issue" Importance: High --------------------------------------------------~--------------------- Store's Details 1430 01 4003966 ST 351 So. Washburn St. Oshkosh, WI 54904 17216 Mgr Name: CARLOS RODRIGUEZ Phone: 920 - 2311575 E-mail: STORE-MGR.s01430@STORES.US.wal-mart.com Move in Date: 02/10/2003 ------------------------------------------------------------------------ Thank You, Paul Humphreys Phone 479-204-0706 email paul.humphreys@wal-mart.com 3 -----Original Message----- From: Linda Fade [mailto:lfade@rci1.netJ Sent: Thursday, November 16, 2006 7:51 AM To: Paul Humphreys Subject: Re: STORE 1430, Oshkosh, WI Hello Paul WO# 1608438 Our tech has met with manager Carlos Redriquez at this location and the manager is not aware of any issue about an extension to a vent pipe No other members of management quite knew about it either when I called to let them know that we would have someone out to take care of that, and they said to find out from Carlos. But he does not know either. Let me know if you can find out where they are needing this extension. the actual work order did not specify an area. Thanks Linda Original Message From: Linda Fade To: wmpb@wal-mart.com Sent: Wednesday, November 08, 2006 3:12 PM Subject: STORE 1430, Oshkosh, WI Hello Paul WO# 1608438 adding extenstion to vent pipe notified store management, asst. ETA first of next week, 11/13/06 Thank you Linda Fade Project Manager Registered Contractors, Inc. Phone: 800-324-9389 Fax: 440-205-0879 Email: Ifade@rci1.net ****************************************************~************** *** This email and any files transmitted with it are confidential and intended solely for the individual or entity to whom they are addressed. If you have received this email in error destroy it immediately. ****************************************'************** **************** Wal-Mart Confidential **************************** ****************************************** 4 Message Page 1 of6 Dannhoff, Allyn J. From: Dannhoff, Allyn J. Sent: Thursday, January 18, 2007 3:58 PM To: 'Joe Ward' Subject: RE: STORE 1430, Oshkosh, WI Dr. Mr. Ward; Coincidentally I was reviewing this file earlier this week. To date I have no evidence that a revised HVAC plan has been sent to the state and as a result I have not performed an inspection to determine compliance. I have not heard anything from anyone since we last exchanged e-mails, phone calls. Please let me know if you find anything out. Thanks. Allyn -----Original Message----- From: Joe Ward [mailto:Joe.Ward@wal-mart.com] Sent: Thursday, January 18, 2007 3:19 PM To: Dannhoff, Allyn J. Cc: slemke@hunzinger.com; 01430-U5-STORE MGR Subject: RE: STORE 1430, Oshkosh, WI -, AHen, I am following up to make sure we have complied. Please confirm. Thanks, Joe Ward Project Manager Income Development lA, IL, IN, MI, MN, MO, WI Wal-Mart Stores Inc. P: 479-277-0180 F: 479-204-2263 joe.ward@wal-mart~com ~ Please consider the envimnment before printing this email -----Original Message----- From: Dannhoff, Allyn J. [mailto:adannhoff@ci.oshkosh.wi.us] Sent: Wednesday, November 22,200610:27 AM To: Joe Ward Cc: 'slemke@hunzinger.com'; 01430-U5-STORE MGR 1/18/2007 Mi;.ssage Page 2 of6 Subject: RE: STORE 1430, Oshkosh, WI Good Morning Mr. Ward; I was advised by Shem Lemke of Hunzinger that you would be the most appropriate person to contact about the following issue: I was contacted by a local HV AC contractor that had been contacted by your company about modifying an existing HV AC system to address the odor issue created by the Nail Salon and is affecting air quality for the adjacent Aurora Quick Care Center at the Oshkosh, Wisconsin Wal-Mart. Please note this information has revealed there are Code Issues to be corrected at this site. Per the HV AC Plans for the Quick Care Center, these two spaces share one HV AC System and the return air duct for this system is located in the Nail Salon. As a result the return air is transferring the odors from the Nail Salon into the adjacent Quick Care Center. Please note this situation creates the folIowing violations (or potential violations) of the State of Wisconsin Building & HV AC Code: 1. The Nail Salon, per COMM table 64.0403, would be classified as a Beauty Salon and as such is required to provide 1/2 cfm per s.f. of floor area of exhaust (to be exhausted directly to the outdoors.) It is unknown if this has been provided. 2. Comm 64.0403 3. Where mechanical exhaust is required by table 64.0403, recirculation of air from such spaces shalI be prohibited. AIl air supplied to such spaces shall be exhausted, including any air in excess of that required by Table 64.0403. In layman's terms, no air from the Nail Salon (because it is contaminated/odored) can be introduced into other areas of this building. As a result, revised HV AC Plans shalI be required to be submitted to the State for review and approval to address this design oversight. Please note, the present State Approved Plans did not identify that a Nail Salon existed and would be sharing the HV AC system with the Quick Care Center. Please advise me what steps will be taken to comply and the time frame that is anticipated in complying. If you have any questions, please calI me at 920-236-5045. Sincerely; Allyn Dannhoff Director of Inspection Services City of Oshkosh -----Original Message----~ From: slemke@hunzinger.com [mgjltQ;~l~IJJk~@l;mnzj1;1gIT,(:Qm] Sent: Wednesday, November 22,20069:36 AM To: adannhoff@ci.oshkosh.wi.us Subject: FW: STORE 1430, Oshkosh, WI 1/18/2007 Message Page 3 of6 Shem Lemke Project Manager Hunzinger Construction Company 21100 Enterprise Avenue Brookfield, WI 53045 262.780.9117 262.797.0474 fax ----- Forwarded by Shem Lemke/hunzinger on 11/22/2006 09:34 AM _____ "Joe Ward" <Joe.Ward@wal-mar To: "Kerr, Matthew" <Matthew.Kerr@zdg.com> t.com> cc: <john.rydzewski@aurora.org>, <slemke@hunzinger.com>, "Baer, Curt G." West" <curt.baer@zdg.com>, "Jansen, Lisa C" <lisa.jansen@ZDG.com>, "Denise 11/16/200608:07 <Denise.West@wal-mart.com> AM Subject: FW: STORE 1430, Oshkosh, WI Matthew, Please note that this is being addressed in this matter. Please monitor the situation and let me know if you need more help. Thanks, Joe Ward Project Manager Income Development IA, IL, IN, MI, MN, MO, WI Wal-Mart Stores Inc. P: 479-277-0180 F: 479-204-2263 joe. ward@wal-mart.com 1/18/2007 Me%sage Page 4 of6 -----Original Message----- From: Paul Humphreys Sent: Thursday, November 16, 20067:54 AM To: o 1430-US-OFFICE ASSOC; o 1430-US-STORE MGR; 01430-US-STORE CO MGR Cc: Joe Ward; 'Linda Fade' Subject: FW: STORE 1430, Oshkosh, WI Importance: High Joe Ward with Branded foods brought the odor issue to our attention. Rci is needing to add an extension to the vent pipe so odors cannot come into the medic area. -----Original Message----- From: Joe Ward Sent: Monday, November 06, 20064:54 PM To: 'Kerr, Matthew'; Paul Humphreys Cc: john.iydzewski@aurora.org; slemke@hunzinger.com; Baer, Curt G.; Jansen, Lisa C; Denise West; Sharon Gregory Subject: RE: Quick Care - HV AC Issue Importance: High Store's Details 1430014003966 ST 351 So. Washburn St. Oshkosh, WI 5490417216 Mgr Name: CARLOS RODRIGUEZ Phone: 920 - 2311575 1/18/2007 M~ssage Page 5 of6 E-mail: STORE-MGR.s01430@STORES.US.wal-mart.com Move in Date: 02/1 0/2003 ----------------------------------------------------------------------------J..------__________________________: Thank You, Paul Humphreys Phone 479-204-0706 email pau1.humphreys@wal-mart.com -----Original Message----- From: Linda Fade LmqUJQ:Ifqg~@rGiLnGt] Sent: Thursday, November 16, 2006 7:51 AM To: Paul Humphreys Subject: Re: STORE 143'0, Oshkosh, WI . Hello Paul WO# 1608438 Our tech has met with manager Carlos Redriquez at this location and the manager is not aware of any issue about an extension to a vent pipe No other members of management quite knew about it either when I called to let them know that we would have someone out to take care of that, and they said to fmd out from Carlos. But he does not know either. Let me know if you can fmd out where they are needing this extension. the actual work order did not specify an area. Thanks Linda ----- Original Message ----- From: Linda Fade To: wmpb@wal-mart.com Sent: Wednesday, November 08,20063:12 PM Subject: STORE 1430, Oshkosh, WI Hello Paul WO# 1608438 1/18/2007 Nlessage adding extenstion to vent pipe notified store management, asst. ETA first of next week, 11/13/06 Thank you Linda Fade Project Manager Registered Contractors, Inc. Phone: 800-324-9389 Fax: 440-205-0879 Email: lfade@rcil.net ******************************************************************* *** This email and any files transmitted with it are confidential and intended solely for the individual or entity to whom they are addressed. If you have received this emaiI in error destroy it immediately. * * * ** *** *** * ** * * ** * * ** * * ** * * ** * * '" *** * ** *** * ** * ** * ** * ** **************** Wal-Mart Confidential **************************** ****************************************** ****************** ** * ********** ****** *** ****'*********************** *** This email and any files transmitted with it are confidential and intended solely for the individual or entity to whom they are addressed. If you have received this em ail in error destroy it immediately.****************************************************** **************** Wal-Mart Confidential **************************** *****************~************************ 1/18/2007 Page 6 of6 Dannhoff, Allyn J. From: Sent: To: Subject: Dannhoff, Allyn J. Thursday, April 19, 20071 :10 PM 'Joe.Ward@wal-mart.com' FW: Plan review, County of WINNEBAGO, City of OSHKOSH Joei Apparently the HVAC issue with the Aurora Quick Care is not,"being attended to by your designers. The plans submitted to the state were denied due to non-response to a previous inquiry. "'~ 'j; At some point, this office will have to issue a Correction Notice to cease occupancy of these spaces until compliance is provided. Please advise what steps are being taken to correct this issue. Thanks. Allyn Dannhoff 920-236-5045 -----Original Message----- From: AutoSend@commerce.state.wi.us [mailto:AutoSend@commerce.state.wi.us] Sent: Thursday, April 19, 2007 9:20 AM To: peter.ochs@wisconsin.govi adannhoff@ci.oshkosh.wi.uSi duane.henderson@hendersonngieers.comi brad.moore@brrarch.com Subject: Plan review, County of WINNEBAGO, City of OSHKOSH Transaction ID: 1348557 Site: WALMART SUPERCENTER #1430 351 S WASHBURN ST OSHKOSH 54901 Designer(s) : DUANE S HENDERSON This email is sent to you from the Wisconsin Department of Commerce, Safety and Buildings Division, regarding review ofa plan submittal identified by Transaction ID, above. Agency contact information is in the letter and on our WEB site. Click on the following attachment to retrieve the subject letter MS Word format: <http://apps.commerce.wi.gov/COM_CLA/Regobj?f=661898&k=483921> PDF format: <http://apps.commerce.wi.gov/COM_CLA/RegObj?f=661898&k=483921&w=p> A hard copy of this letter will NOT be mailed to you. Copies of the signed approval letter will be attached to approved plan sets. The attachment is available for 21 days from this email. Safety and Buildings WEB home page: <http://www.commerce.wi.gov/sb/> Agency contacts: <http://www.commerce.wi.goV/SB/SB-DivContacts.html> Do not reply to this email.This is an automated email account that does not accept responses 1 c,., DUANE S HENDERSON Page 2 4/19/2007 cc: Peter R Ochs, State Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. Boice Raidl Rhea Architects Inc Walmart Stores Inc Brad Moore, Boice Raidl Rhea Architects (Plans Mailed To) .j' ~./J commerce.wi.gov ~L!!2gJ)!m~!:! Safety and Buildings 141 NW BARSTOW ST FL 4TH WAUKESHA WI 53188-3789 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov April 19, 2007 Jim Doyle, Governor Mary P. Burke, Secretary CUST IDNo. 918808 A TTN: Buildings & Structures Inspector BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 DUANE S HENDERSON HENDERSON ENGINEERS INC 8325 LENEXA DR STE 400 LENEXA KS 66214 DENIAL OF REQUEST FOR APPROVAL SITE: Wa1mart Supercenter #1430 351 S Washburn St City of Oshkosh, 54901 ; Fire Dept ill: 7003 FOR: TENANT ALTERATION (B)/HV AC ONLY FOR TENANT A & B Object Type: HV AC ICC System Regulated Object ID No.: 1110764 950 sq ft Area Heated Reviewed for conformance with Chs. Comm 61-65 . The submittal as described above has been reviewed foryonformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes listed in th,e regarding line above. The submittal is being returned DENIED. The non-approval action is based upon the following: . The above submittal has been denied due to non-response to additional information requests. If you wish to continue with this project, it must be resubmitted, in quadruplicate, and be accompanied by an Application for Submittal form and r~quired fees. The resubmitted materials must be revised to show compliance with the items indicated above. Note that the code in effect at the time ofre-submittal would apply. All of the data and statements submitted were considereq. Sincerely, Tariq Masood Plan Reviewer, Integrated Services (262)548-8608,07:45 To 16:30 tariq .masood@wisconsin.gov Fee Required $ Fee Received $ Refund Amt $ 230.00 340.00 11 0.00 ""","Ii commerce.wi.gov ~!!E9Jl!Je!:! Safety and Buildings 141 NW BARSTOW ST FL 4TH WAUKESHA WI 53188-3789 TOO #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary February 27,2007 CUST ID No. 918808 Fee Required $ Fee Received $ Refund Amt $ 230.00 340.00 110.00 DUANE S HENDERSON HENDERSON ENGINEERS INC 8325 LENEXADR STE 400 LENEXA KS 66214 REQUEST FOR ADDITIONAL INFORMATION SITE: Wa1mart Supercenter #1430 351 S Washburn St City of Oshkosh, 54901 ; Fire Dept ID: 7003 FOR: Description: TENANT ALTERATION (B)/HVAC ONLY FOR TENANT A & B Object Type: HV AC ICC System Regulated Object ID No.: 1110764 950 sq ft Area Heated The submittal described above has been placed on HOLI) and the review and approval is pending subject to receipt of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional information and/or revised plans, the plans will be reviewed for compliance to applicable Wisconsin Adminjstrative Codes and Wisconsin Statutes. The following must be corrected/revised and accompany the resubmittal: As you have not satisfactorily responded to my plan examination letters dated December 11, 2006 & January 30, 2007, your plans are subject to denial. Please respond to my plan examination letters within next 10 working days to avoid a denial action. Send your resubmittal into the address listed above, unless otherwise noted, and the department will review the resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. If you have any questions, after reading the above comments and related code sections cited, please call me at the telephone number below. If the abQye requested information and/or plans are not received within 30 business days ofthe date ofthjs correspondence, this submittal will be returned denied. No fees will be refunded, and a new fee, application form, and submittal of plans/specifications will be required should you desire to continue with this project. The code in effect at the time of new submittal would apply. ~ ' DUANE S HENDERSON Sincerely, Tariq Masood Plan Reviewer, Integrated Services (262)548-8608,07:45 To 16:30 tariq.masood@wisconsin.gov Page 2 2/27/2007 cc: Peter R Ochs, State Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. Brad Moore, Boice Raidl Rhea Architects (Plans Mailed To)