Loading...
HomeMy WebLinkAbout0092902-Electric (relocate panels) .", e OSHKOSH ON THE WATER Job Address 3300 MEDALIST DR CITY OF OSHKOSH No 92902 ELECTRIC PERMIT - APPLICATION AND RECORD Owner SQUARE D CO Create Date 03/04/2002 Service p New o Change o Temp Category 653 - Industrial-Addition/Remodels Type 0 Overhead Plan o Underground Contractor VOS ELECTRIC, INC. Volts Circuits o o Fixtures o o Amps o Switches Receptacles Appliances Use/Nature of SQUARE D COMPANY (Demolition & Relocation of electrical panels) Work Fees: Valuation Issued By: +< fJ' $28,000.00 Plan Approval $0.00 Permit Fee Paid $234.00 Date 03/04/2002 D Permit Voided: Signature all w rk pursuant to rules governing the described construction. Date 7~fi3c%L- Address 3138 MARKET STREET Agent/Owner GREEN SAY WI 54304 - 0 Telephone Number (920) 336-0781 Mar 04 02 08:08a " -< Oshkosh Inspections 920-236-5084 p. 1 ~ ~QtH Division of Inspection Services 215 Church Avenue P.O. Box 1130 Oshkosh, WI 54903-1130 Fax (920) 236-5084 Phone (920) 236-5046 ELECTRICAL PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. DATE 0'- "1- d-I?J d- JOB ADDRESS .?~OO 'M~L1ST OR. OWNER GE. C.RANt> CONTRACTOR VOS' 1:::'Uc(:.~ \c:-- :t..... '\ t_ CIRCLE ALL APPLICABLE USE CATEGORY SINGLE FAMILY DUPLEX MULTI-FAMILY RENTAL COMMERCIAL INDUSTRIAL SERVICE NEW c6ffiNgi) TYPE OVERHEAD UNDERGROUND TEMPORARY NOT APPLICABLE ~OTAPP~ NO. OF FIXTURES SWITCHES RECEPTACLES CIRCUITS AMPS / PHASE VOLTS CHECK ALL APPLICABLE RANGE WATER HEATER GARBAGE DISPOSAL DRYER DISHWASHER FAN OR BLOWER FURNACE A/C_ ELECTRIC SIGN____ MOTORS GAS PUMPS OTHER DESCRIPTION OF ALL WORK BEING DONE Q. EL&c..~ '11010 OF EJ...Et. _If< I (' A { /Ji!v J C~S + ~ArJ ElLS · Submit payment with application. Failure tb pay within 30 days will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. VALUE (Including labor and all materials including light fixtures) $ ~~. to\~ ~ I MASTER ELECTRICIAN Job Address 3308 MEDALIST DR Electric Permit Work Card Permit Number 92902 Create Date 3/4/2002 Owner SQUARE D CO Service b New 0 ChangeO Temp . N/A Volts Circuits 0 Contractor VOS ELECTRIC INC Type 0 Overhead 0 Underground . N/A Luminaires Amps o Switches o Receptacles o o Value $28,000.00 Use/Nature 653 - Industrial-Addition/Remodels SQUARE D COMPANY (Demolition & Relocation of electrical panels) of Work Inspections: Date Type Rough In Inspector REQUEST FROM THE BUILDING INSPECTOR. (4/8/02 11 :44 AM the building inspector witnessed the installation of 9 3/0 cu conductors eing pulled in 3" conduit thru 6 90's, 2 offsets & 1 j-box being pulled in with a crane. The electricians were pulling straightthru the j-box.) I erified the installation to be 3" EMT & the j-box is 18"X18". DatelTime requested: 04/12/2002 10:37 AM Access: Requested by: o Reinspect Fee 0 Fee Wavied Notice Type: Ready DatelTime: 04/12/2002 Phone Number: o Reinspect Fee Paid Date Type Final reoo.., from ~e 'olld'o. '""ecro, DatelTime requested: 05/13/2002 09:56 AM Access: Requested by: o Reinspect Fee 0 Fee Wavied Inspector Kevin Benner Notice Type: Ready DatelTime: 05/13/2002 09:56 AM Phone Number: o Reinspect Fee Paid Benner. Kevin From: Sent: To: Cc: doug. thurber@ps.ge.com Tuesday, September 03, 20022:44 PM larry@excellence-electric.com tony. neely@ps.ge.com; barry.weinbrenner@ps.ge.com; kbenner@ci.oshkosh.wi.us; larry@excellence-electric.com Larry, On Aug. 29, 2002 GE Power Systems/AC Compressor was inspected by the city of Oshkosh. Kevin Benner, Brian Noe, and Douglas Thurber were present during the inspection. The following is a list of violations needing correction from Excellence Electric. 1. Inspect all disconnects and correct grounding. Found three instances of two ground wires one a single lug on the paint booth. 2. Inspect all 30 amp outlets and correct grounding:o'Found 12 gauge ground on 30 amp outlets in the pipeshop. 10 gauge wire required here. 3. Ground building with new GE service to the main plant. 'i:' 4. Clarify with Kevin his expectations on conductor identification and remedy. Cordially, Douglas Thurber 1 Benner. Kevin From: Sent: To: Cc: doug. thurber@ps.ge.com Wednesday, September 04,20027:19 AM philip.plowman@ps.ge.com tony.neely@ps.ge.com; barry. weinbren ner@ps.ge.com; kben ner@ci.oshkosh.wLus Phill, On Aug.29, 2002 GE Power Systems/AC Compressor was inspectedby the city of Oshkosh. Kevin Benner, Brian Noe, and Douglas Thurber was present for the inspection. The following is a list of violations needing correction from Vos Electric. You will need to forward this list to your connection at Vos. 1. Two wires under one lug on office trans former 2. Equipment ground sized to small on office transformer 3. Boxes not anchored under floor in computer room 4. Flex conduit not anchored in computer room 5. Two wires under single lug on 350 amp breaker and 400 amp panel 6. Ground not bonded in pull boxes 7. LB cover missing in break room 8. Class 2 and power wires not seperated in fire suppression system in the computer room 9. Box cover missing at employee entrance 10. Kevin requested pull tension calculations from Vos for the 350 amp circuit for the compressors 1 Benner. Kevin From: Sent: To: Cc: doug. thu rber@ps.ge.com Wednesday, September 04, 2002 7:54 AM barry. weinbrenner@ps.ge.com tony.neely@ps.ge.com; kbenner@ci.oshkosh.wLus Barry, Outstanding issues from inspection on Aug.29. 1. Clearance on disconnect by pumping station (Ogden Plumbing) We were not going to take action on this item until the pumping station is operational. 2. Paint Booth contractor needs permit and contractors license. 3. Third party listing on Hawkinson dryer. 4. Exhaut Fan on roof has exposed wires (Central Temp) 5. Wires run in exhaust plenum (GE Power Systems) 6. Misc. knockout enclosures ( GE Power Systems) 7. Post drawings of electrical distribution locations (GE Power Systems) 8. Evaluate our use of extension cords and hard wire permanent applications. ie portable parts cleaner in assembly. 9. Label entire electrical system (GE Power Systems) Please advise on how to handle Centrals violation on the fan. Douglas 1 .^.~.;'i::;./.."...,-"..4,...,.',.,)j,.;\(..< Benner. Kevin From: Sent: To: Subject: doug. th urber@ps.ge.com Wednesday, September 04,20027:59 AM Kbenner@ci.oshkosh.wi.us breaker test results Kevin, I have requested the test results for the 3000 amp main breaker. I will post the results when i receive them from GE. Douglas 1 Benner. Kevin From: Sent: To: Subject: doug. thurber@ps.ge.com Thursday, September 05, 2002 8:02 AM kbenner@ci.oshkosh.wi.us FW: Central Temp > -----Original Message----- > From: Weinbrenner, Barry (PS, ACC) > Sent: Thursday, September 05, 2002 7:46 AM > To: Thurber, Doug (PS, ACC) > Subject: Central Temp > > Doug, Bill Hoffman from Central Temp will be here tomorrow at 9:00am > to see us regarding the code issues you forwarded to me. I want you to > show him what is at issue. Also can you take him in the front offices and > show him the problems with the control wiring there? > > Thank you. > > Barry Weinbrenner > GE Power Systems/A-C Compressor > DC 8 323-6007 > P-920-237-6007 > F-920-730-7108 > Cell 920-470-0725 > barry.weinbrenner@ps.ge.com > 1 Benner, Kevin From: Sent: To: Subject: Ewing, Monte [mewing@commerce.state.wi.us] Thursday, October 10, 200210:37 AM 'Benner, Kevin' RE: Air Dryer Opinion I agree with you that the motor control panel as presently located violates Comm 16.18 and NEC 110-26. Most service people will test the motor control transformer output while it is energized and more than likely the complete system. I also agree that turning the enclosure gO-degrees to face the compartment access should bring the control panel into compliance. You may need to explain the manufacture or the listing agent than Comm 16.18 modifies NEC 11 0-3(b) that it must still comply with the code whether the product is listed or not. I assume that the appliance disconnect is located within sight from this appliance? > -----Original Message----- > From: Benner, Kevin [SMTP:kbenner@ci.oshkosh.wi.us] > Sent: Tuesday, October 08, 2002 11 :36 AM > To: 'mewing@commerce.state.wi.us' > Subject: Air Dryer Opinion > > <<Hankinson - GE Compressor.doc>> > Greetings Monte, > In the enclosed attachment are the pictures of the Hankinson air dryer we > discussed earlier. Your opinion of the working space for the electrical > enclosure would be appreciated. > > Thank you, > Kevin Benner << File: Hankinson - GE Compressor.doc >> 1 Benner, Kevin From: Sent: To: Cc: Subject: Pritchard, Brian [BPRITCHARD@hankisonintl.com] Friday, October 11,200212:31 PM 'Benner, Kevin' Szybowski ,Bill RE: Air Dryer Opinion Kevin, One of our service technicians is going to be in the area next week. He will be making the necessary modifications to the unit. We will be looking at some things here to incorporate a more user-friendly design on future models. Sorry for all the inconvenience. We generally design equipment to meet CSAlUL specs., but occasionally local coding causes us to make a change, as in this case. Thanks for your help. Regards, Brian -----Original Message----- From: Benner, Kevin [mailto:kbenner@cLoshkosh.wLus] Sent: Friday, October 11, 2002 1 :05 PM To: 'BPRITCHARD@hankisonintl.com' Subject: FW: Air Dryer Opinion Hi Brian, Comm 16 is the State of Wisconsin Department of Commerce Electrical Code which adopts NFPA 70 (NEC) with additions, modifications and alterations as the department deems necessary. 16.18 reads as follows: Installations and use [NEC110-3]. substitute the following wording for NEC 110-3(b): Listed or labeled equipment shall be installed or used,or both, in accordance with any instructions included in the listing or labeling, provided the instructions, listing or labeling do not conflict with this chapter. Regards, Kevin Benner -----Original Message----- From: Pritchard, Brian [mailto:BPRITCHARD@hankisonintl.com] Sent: Friday, October 11,20029:50 AM To: 'Benner, Kevin' Subject: RE: Air Dryer Opinion Kevin, Thanks for the information. Please excuse my ignorance but what is "Comm 16.18"? Also, I have not received the pictures. Can you please send them again. will give you call after looking over some things and having some discussions with people here. Regards, 1 ,. Benner, Kevin From: Sent: To: Subject: Ewing. Monte [mewing@commerce.state.wi.us] Thursday, October 10, 2002 10:37 AM 'Benner, Kevin' RE: Air Dryer Opinion I agree with you that the motor control panel as presently located violates Comm 16.18 and NEC 110-26. Most service people will test the motor control transformer output while it is energized and more than likely the complete system. I also agree that turning the enclosure gO-degrees to face the compartment access should bring the control panel into compliance. You may need to explain the manufacture or the listing agent than Comm 16.18 modifies NEC 110-3(b) that it must still comply with the code whether the product is listed or not. I assume that the appliance disconnect is located within sight from this appliance? > -----Original Message----- > From: Benner, Kevin [SMTP:kbenner@ci.oshkosh.wLus] > Sent: Tuesday, October 08. 2002 11 :36 AM > To: 'mewing@commerce.state.wi.us' > Subject: Air Dryer Opinion > > <<Hankinson - GE Compressor.doc>> > Greetings Monte, > In the enclosed attachment are the pictures of the Hankinson air dryer we > discussed earlier. Your opinion of the working space for the electrical > enclosure would be appreciated. > > Thank you, > Kevin Benner << File: Hankinson - GE Compressor.doc >> 1 Benner, Kevin From: Sent: To: Subject: Pritchard, Brian [BPRITCHARD@hankisonintl.com) Thursday, October 10, 2002 1 :23 PM 'kbenner@ci.oshkosh.wi.us' em ail -bpritchard@hankisonintl.com I will be looking forward to the pictures. Did you hear anything back yet? Brian W. Pritchard Engineer - New Product Development Hankison International Phone 724-746-4240 ext 240 Fax 724-745-6040 Visit us at: www.hankisonintl.com ********************************************************************** This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the system manager. This footnote also confirms that this email message has been swept by MIMEsweeper for the presence of computer viruses. www.mimesweeper.com ********************************************************************** 1 Benner, Kevin From: Sent: To: Subject: Pritchard, Brian [BPRITCHARD@hankisonintl.com] Friday, October 11,20029:50 AM 'Benner, Kevin' RE: Air Dryer Opinion Kevin, Thanks for the information. Please excuse my ignorance but what is "Comm 16.18"? Also, I have not received the pictures. Can you please send them again. will give you call after looking over some things and having some discussions with people here. Regards, Brian -----Original Message----- From: Benner, Kevin [mailto:kbenner@cLoshkosh.wi.us] Sent: Friday, October 11, 2002 8:17 AM To: 'BPRITCHARD@hankisonintl.com' Subject: FW: Air Dryer Opinion Brian, This the reply I received from Mr. Ewing at the Department of Commerce. -----Original Message----- From: Ewing, Monte [mailto:mewing@commerce.state.wi.us] Sent: Thursday, October 10, 2002 10:37 AM To: 'Benner, Kevin' Subject: RE: Air Dryer Opinion I agree with you that the motor control panel as presently located violates Comm 16.18 and NEC 110-26. Most service people will test the motor control transformer output while it is energized and more than likely the complete system. I also agree that turning the enclosure 90-degrees to face the compartment access should bring the control panel into compliance. You may need to explain the manufacture or the listing agent than Comm 16.18 modifies N EC 11 0-3(b) that it must still comply with the code whether the product is listed or not. I assume that the appliance disconnect is located within sight from this appliance? > -----Original Message----- > From: Benner, Kevin [SMTP:kbenner@ci.oshkosh.wi.us] > Sent: Tuesday, October 08,2002 11 :36 AM > To: 'mewing@commerce.statewi.us' > Subject: Air Dryer Opinion > > <<Hankinson - GE Compressor.doc>> > Greetings Monte, > In the enclosed attachment are the pictures of the Hankinson air dryer we > discussed earlier. Your opinion of the working space for the electrical > enclosure would be appreciated. > > Thank you, > Kevin Benner << File: Hankinson - GE Compressor.doc >> 1 ********************************************************************** This em ail and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this em ail in error please notify the system manager. This footnote also confirms that this email message has been swept by MIMEsweeper for the presence of computer viruses. www.mimesweeper.com ********************************************************************** 2 Benner, Kevin From: Sent: To: Cc: Subject: Pritchard, Brian [BPRITCHARD@hankisonintl.com] Friday, October 11,2002 12:31 PM 'Benner, Kevin' Szybowski ,Bill RE: Air Dryer Opinion Kevin, One of our service technicians is going to be in the area next week. He will be making the necessary modifications to the unit. We will be looking at some things here to incorporate a more user-friendly design on future models. Sorry for all the inconvenience. We generally design equipment to meet CSAlUL specs., but occasionally local coding causes us to make a change, as in this case. Thanks for your help. Regards, Brian -----Original Message----- From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Friday, October 11, 2002 1 :05 PM To: 'BPRITCHARD@hankisonintl.com' Subject: FW: Air Dryer Opinion Hi Brian, Comm 16 is the State of Wisconsin Department of Commerce Electrical Code which adopts NFPA 70 (NEC) with additions, modifications and alterations as the department deems necessary. 16.18 reads as follows: Installations and use [NEC11 0-3]. substitute the following wording for NEC 11 0-3(b): Listed or labeled equipment shall be installed or used,or both, in accordance with any instructions included in the listing or labeling, provided the instructions, listing or labeling do not conflict with this chapter. Regards, Kevin Benner -----Original Message----- From: Pritchard, Brian [mailto:BPRITCHARD@hankisonintl.com] Sent: Friday, October 11, 2002 9:50 AM To: 'Benner, Kevin' Subject: RE: Air Dryer Opinion Kevin, Thanks for the information. Please excuse my ignorance but what is "Comm 16.18"? Also, I have not received the pictures. Can you please send them again. will give you call after looking over some things and having some discussions with people here. Regards, Brian -----Original Message----- From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us) Sent: Friday, October 11,20028:17 AM To: 'BPRITCHARD@hankisonintl.com' Subject: FW: Air Dryer Opinion Brian, This the reply I received from Mr. Ewing at the Department of Commerce. -----Original Message----- From: Ewing, Monte [mailto:mewing@commerce.state.wi.us] Sent: Thursday, October 10, 2002 10:37 AM To: 'Benner, Kevin' Subject: RE: Air Dryer Opinion I agree with you that the motor control panel as presently located violates Comm 16.18 and NEC 110-26. Most service people will test the motor control transformer output while it is energized and more than likely the complete system. I also agree that turning the enclosure gO-degrees to face the compartment access should bring the control panel into compliance. You may need to explain the manufacture or the listing agent than Comm 16.18 modifies NEC 11 0-3(b) that it must still comply with the code whether the product is listed or not. I assume that the appliance disconnect is located within sight from this appliance? > -----Original Message----- > From: Benner, Kevin [SMTP:kbenner@ci.oshkosh.wi.us) > Sent: Tuesday, October 08,2002 11 :36 AM > To: 'mewing@commerce.state.wi.us' > Subject: Air Dryer Opinion > > <<Hankinson - GE Compressor.doc>> > Greetings Monte, > In the enclosed attachment are the pictures of the Hankinson air dryer we > discussed earlier. Your opinion of the working space for the electrical > enclosure would be appreciated. > > Thank you, > Kevin Benner << File: Hankinson - GE Compressor.doc >> ********************************************************************** This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this em ail in error please notify the system manager. This footnote also confirms that this email message has been swept by . MIMEsweeper for the presel,lce of computer viruses. www.mimesweeper.com ********************************************************************** 2