HomeMy WebLinkAboutHVAC W1-109-1106-H '~ ~ OJHKOIH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wLus ON THE WATER November 22, 2006 Keith Paul Gartman Mechanical Services 520 W South Park Ave Oshkosh, WI 54903 Ron Detjen Landmark LTD III PO BOX 2366 Oshkosh WI 54903 Site: Plan Number: WI-I09-1106-H U Bake 374 S KoellerSt. Oshkosh WI 54903 For: Description: Tenant space alterations Object Type: HV AC only Class of Construction: llB -1653 Sq Ft.; Srinklered Occupancy: M: Mercantile I Retail The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item{s) I Conditions: . IBC 1101.2/ANSI A117.1-308.2 & 3 - Mechanical system controls shall be located a maximum of 48" above the finished floor if the floor space allows a forward approach by a wheel chair or if the clear space allows a parallel approach. Caution on location ofT-Stat above counter space. . IMC 403.3.4 Balancing Ventilation systems shall be balanced by an approved method. Such balancing shall verify that the ventilation system is capable of supplying the airflow rates required by Section 403. . IMC 606.2.1 Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm... .. .Per the plans submitted the total cfm for the system is 1995, which does not required the installation of a smoke duct detector, however should the balancing of the system to meet [MC 403.3.3 cause this to increase detectors may be required. . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documepts that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). \\OSllKOSfli\:JISFS'I'SFRS'"br:ann'2006 Cornm Plan R",'iew"\VI.II)'J"! {()6 374 $ Ko~lIer $1 HVAC On1\'.doc Page 1 of2 . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to connnencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 10 1.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. RespW ~~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 230.00 230.00 0.00 ......OSIIKOSi I \'1 hFS-,uSERS"'bri,um"'2006 Comm Plan n,,";ew\WI.j{)i).II06 374 S Kt>dl"r S1 11V A(' Onh.jo(,' Page 2 of2