HomeMy WebLinkAbout13377-Electrical maintenance
e
OSHKOSH
ON THE WATER
Issue Date 12/11/2007
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 1/10/2008
Compliance No
Address
855 FREDERICK ST
Sent to
U Owner
Name
I GREGORY A BRAHMER
Address
851 FREDERICK ST
City
OSHKOSH
State Zip Code
WI 54901 -4410
Introduction
~hile conducting a property maintenance inspection it was noted that code violations are present on your property. Several
~acets of the electrical system are in an unsafe condition. Please contact an electrician to make corrections.
U Required for Occupancy
Occupancy
Item # 7 Code WI Comm 82.38 Compliance No Compliance Date 01/10/2008
Description Condensate from high efficiency furnace or water heater shall discharge to municipal sanitary sewer.
12/11/2007
Last
Updated
Item # 8 Code Mun Code 16.35(A)(3) Compliance No Compliance Date 01/10/2008
Description ~racked/damagedlleaking fixtures or other plumbing conditions, which create un-sanitary conditions or unusable fixtures, shall be
eplaced/repaired by a licensed plumber with permit.
12/11/2007
Last
Updated
Item # 9 Code Mun Code 11 & 20 Compliance Not Checked Compliance Date 01/10/2008
Description Plumbing and electrical work in rental properties required to be performed by licensed contractors with respective permits.
12/11/2007
Last
Updated
13377
Page 2 of 3
o
OSHKOSH
ON THE WATER
Issue Date 12/11/2007
Address 855 FREDERICK ST
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 1/10/2008
Compliance No
Address
851 FREDERICK ST
City
OSHKOSH
State Zip Code
WI 54901 -4410
Sent to
U Owner
Name
I GREGORY A BRAHMER
Introduction
While conducting a property maintenance inspection it was noted that code violations are present on your property. Several
Iracets of the electrical system are in an unsafe condition. Please contact an electrician to make corrections. .
U Required for Occupancy
Occupancy
Item # 10 Code Mun Code 7.43 Compliance No Compliance Date 01/10/2008
Description Before commencing construction, installation, alteration or remodeling of any heating, ventilating, or air conditioning system, or part of a
~ystem, a permit shall first be secured. There is no record of a permit for the furnace replacement.
12/11/2007
Last
Updated
Summary Please contact a HVAC contractor, plumber, and an electrician to correct these problems in the next 30 days. Feel free to
contact me, or the electrical inspector, Adam Krause, with any questions. You can reach Adam Krause at 236-5274.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 1/10/2008
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature of Whrl'eedS to. be ;nspected.
SIgn"'," #'= ' .f? {.., .. _ Date I Z /" / b I
Inspected by: Andrew Prickett 236-5137 aprickett@ci.oshkosh.wLus
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Company
Signature
Date
Also Sent to: U Bldg
U Elec
U HV AC
U Plbg
U Designer
~ Other DEBBIE BRAHMER
U Inspector I Adam Krause
851 FREDERICK ST
OSHKOSH
WI 54901 -
13377
Page 3 of 3
Violation(s) of at: 855 Frederick St - Address verification
No cover plate
Taken by Andrew Prickett
855 FREDERICK 12-11-071
Working
clearance
required for
electrical
equipment.
NM Cables to
be in a
raceway.
Violation(s) of at: 855 Frederick St.
Temperature and
pressure relief
valve requires
overflow to within
6” from the floor.
Must discharge
into an approved
receptor.
Taken by Andrew Prickett
855 FREDERICK 12-11-072
Splices to take
place in a box
or fitting.
Condensate to
discharge to
sanitary sewer.
Violation(s) of at: 855 Frederick St.
NM Cables to be in
a raceway.
Taken by Andrew Prickett
855 FREDERICK 12-11-073