Loading...
HomeMy WebLinkAbout0091943-Electric (machine line) ,~~. - .. OSHKOSH ON THE WATER Job Address 3555 MOSER ST Contractor VAN ERT ELECTRIC CITY OF OSHKOSH No 91943 ELECTRIC PERMIT - APPLICATION AND RECORD Service b New o Change Owner PACURINC Create Date 12/21/2001 Category 653 - Industrial-Addition/Remodels Plan o Temp Type o Overhead o Underground Circuits Fixtures Switches Receptacles Volts Amps Appliances Use/Nature of I NO/ New machine line #10 extrusion . Job #F1239E Work Fees: Valuation Issued By: _~ $85,000.00 Plan Approval $0.00 Permit Fee Paid $405.00 Date 12/21/2001 D Permit Voided I In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner Address 2000 PROGRESS WAY KAUKUANA WI 54130 - 0 Telephone Number (920) 766-3888 .., ~ OfH<OJH ON THE WATER Division of Inspection Services 215 Church Avenue P.O. Box 1130 Oshkosh, WI 54903-1130 Fax (920) 236-5084 Phone (920) 236-5046 ELECTRICAL PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. DATE /;2- dCJ --0/ JOB ADDRESS 3S:) ~ {Y')t:Y~:r;?j (" f)-\-C ~+ OWNER -VA0~( J-( CONTRACTOR VA r\ '"t. ~-\- CIRCLE ALL APPLICABLE TYPE OVERHEAD DUPLEX MULTI-FAMILY RENTAL COMMERCIAL ~STRIAJ:> CHANGE TEMPORARY <:::::::NOT ~I?PLICABI;E:) UNDERGROUND ~~PPLICAB~ USE CATEGORY SINGLE FAMILY SERVICE NEW NO. OF FIXTURES SWITCHES RECEPTACLES CIRCUITS / PHASE AMPS VOLTS CHECK ALL APPLICABLE RANGE WATER HEATER GARBAGE DISPOSAL DRYER DISHWASHER FAN OR BLOWER FURNACE A/C_ ELECTRIC SIGN MOTORS GAS PUMPS OTHER DESCRIPTION OF ALL WORK BEING DONE N€I~J ('f\I1r~\n?J_ '_\r\P:(::\- ,n ~)t:'+n.. j~~ n~ . Submit payment with application. Failure to pay within 30 days will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. ",jo~~ t- \~3C1 E -:Ye'~\\ ~0\-\ $ ~OO VALUE (Including labor and all materials including light fixtures) $ 85, nna MASTER ELECTRICIANJ" ~ ~)l ~Q n+ ~Cb(yf:# /00 - () 7S"0 - .;::?S-/~ --00000 Electric Permit Work Card Job Address 3555 MOSER ST Permit Number 91943 Create Date 12/21/2001 Owner PACURINC Contractor VAN ERT ELECTRIC Category 653 - Industrial-Addition/Remodels \ b New I Type o 9verhead o Underground ,rvice o Change 0 Temp . N/A . N/A , ./1 -. --'--"'--'~ Volts Circuits 0 Fixtures 0 Amps 0 Switches 0 Receptacles 0 ~ Fee $405.00 0 Value $85,000.00 Appliances Use/Nature IND/ New machine line #10 extrusion * Job #F 1239E of Work ~,~ ~\A{. I / o~/a3 (7 \.\.P'"" ~ ,\&..r-' ~ta ~'K;d .....-v-- ~ I.J ~ or-.\) (tP~~:.,~ /~~~ / ~~~,.:r ~ ~~. ~dI"' r?~~ " ~ ~l'~ ~' .rv.....9/... y,ft/'-' .,,- ~ ~'R~ / ?<r'" .-:~ ~.., ~€f?~ /-. tI'- ~ l~~ ") U?~ ~e-* l L-r ..d~' / 4:;~ v~ .Qc' c:~~ 41".....,1 J ~ 6--~'?'. LP \!--- (b LL \L xr/'l ~r~ Inspections: Date Type Final Inspector Kevin Benner t", Date/Time requested: 12/05/2002 09:28 AM Access: Meet the E.C. on site Ready DatelTime: 12/10/200201:30 PM Requested by: o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Notice Type: Phone Number: ------------------------------------------------------------------------- Date Type Final Inspector Kevin Benner 1/30 ~/ ~ -s:. F-er~ DatelTime requested: 12/20/2002 11 :45 AM Access: Meet Tim Guyani on site Ready Date/Time: 01/02/200309:30 AM Requested by: o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Notice Type: Phone Number: ---------------------------------------------------------------------------------~-~ r Electric Permit Work Card Job Address 3555 MOSER ST Permit Number 91943 Create Date 12/21/2001 Owner PACUR INC Contractor VAN ERT ELECTRIC CO INC Service b New 0 ChangeO Temp . N/A I Type 0 Overhead 0 Underground. N/A Volts Circuits 0 Luminaires 0 Value Amps 0 Switches 0 Receptacles 0 Use/Nature 653 - Industrial-Addition/Remodels INO/ New machine line #10 extrusion * Job #F1239E of Work $85,000.00 Inspections: Date Type Final Inspector Kevin Benner Date/Time requested: 12/05/2002 09:28 AM Access: Meet the E.C. on site Requested by: Phone Number: o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - -- - - - - - -- - - - - - - - - - - - - - - - -- - - - - - - - - - - -- - - - - - - - - - --- - - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - -- - - - - -- - - - -- - - - - - - - - - - - - - - - - -- - - - -- -- Date 01/02/2003 Type Final Inspector Kevin Benner not approved See field notes that were reviewed with the E.C. Notice Type: Ready Date/Time: 12/10/200201 :30 PM Date/Time requested: 12/20/2002 Access: Meet Tim Guyant on site Requested by: o Reinspect Fee 0 Fee Wavied 11:45 AM Notice Type: Ready Date/Time: 01/02/200309:30 AM Phone Number: o Reinspect Fee Paid - - -- - - - -- - - - - - - - - - - -- - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - -- - - - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - - --- - - --- - - - __ - - - __ - - - __ - - - - - - - - - - _.w _ _ _ __ _ _ _ _ _ _ _ _._ _ __ _ _ _ __ _ _ _ ___ " City of Oshkosh Attn.: Mr. Kevin Benner 215 Church Avenue POBox 1130 Oshkosh, VVI 54903-1130 @ Underwriters Laboratories Inc.@ MeMlle DMslon 1285 Walt Whitman Road Melville, NY 11747-3081 USA www.ul.com tel: 1 631 271 6200 fax: 1 631 271 8259 MELVILLE - April 30, 2003 Ram Industries Inc. Attn.: Mr. Quinn Artz Route 61 PO Box 629 Leesport, PA 19533 COpy cc: Melville File Writer AHJ - Benner Our Reference: Subject: E79963,03ME06312,MNUL Field Inspection of Industrial Control Panels Dear Mr. Artz, This will confirm the results of the Field Inspection performed on your Industrial Control Panels. This inspection was performed at: Pacur Inc. 3555 Moser Street Oshkosh, WI 54901 Our inspector informed us of several non-conforming issues with the panels inspected and UL marks were not applied. A copy of the inspection report is included for your reference. Please inform us if and when this service is to be repeated in order to apply UL marks to this equipment. Since all work under this project has been completed, we are instructing our Accounting Department to close this project and bill your company for all accrued charges. If we can be of further assistance, please do not hesitate to contact the undersigned Very truly yours, REVIEWED BY: MITCHELL MARTIN (Ext. 23200) Engineering Project Handler Conformity Assessment Services,30 15LMEL SALVATORE PORCILLO (Ext. 22620) Engineering Group Leader Conformity AssessmentServices,3015LMEL An independent organization working for a safer world with integrity, precision and knowledge. CD .' 'Vi:' U" Ih, Tab key 10 nawgat' Ixlw"n <lato mtry fidds \!!:I Underwriters Laboratories Inc. Field Inspection Non-conformance Summary OEM of Product Inspected: RAM INDUSTRIES INC. Address of OEM Address Line 1: ROUTE 61 Address Line 2: PO BOX 629 City, State: LEESPORT, PA Zip:19533 Area Office Servicin2: OEM: New Jersey/Philadelphia Product Inspected: Model/Catalog Number: 7264, 7265 UL File Number: E79963 Volume: 1 Section: 1 Field Representative: Send a completed copy of this Field Inspection to the: o OEM o OEM Area Office o Area office Coordinator OEM Manufacturers Rep: Quinn Artz On-site Rep: Greg Emenecker Description ofNon-Conformance(s) l. (SAl.l) Unit employs R/C (QVNU2) supplemental protectors used in branch circuit applications such as motor circuits, heater circuits, and transformer protection. 2) (21.2.2) Fan forced ventilation openings exhaust over operator controlled switches. (7264 only) 3) (22.1) Ventilation openings are within 12 inches of arcing components and are not provided with suitable barriers. 4) (52.1) Nameplate does not include "Enclosure Type 1" to derate the enclosure rating (7264 only), manufacturer's name, or largest motor load. (operator pendant is not provided with a nameplate) 5) (52.2) All extemalload ratings are not provided. (one example is page 2 of the 7264 schematic) 6) (54.2) Field wiring terminals are not marked with wire type, temp. rating or torque markings as specified. 7) (59.4) Multi-pin receptacles not marked "For disconnecting use only, not for current rupturing" or equive1ant. 8) (26.2.4) Enclosure fans are not marked as thermally protected, impedence protected, or provided with thermal overloads. 9) (10.2) 600A fuseholder to fuseholder line side spacing is 3/4 inch rather than 1 inch minimum per Table 10.2. (7264 only) After data entry is complete, this form can be password protected for "comments" to avoid unauthorized changes. The gray shading in the data entry fields can also be removed using the "Forms" toolbar. Rev 2/25/03 )., ':" r Iij:\ Underwriters Laboratories Inc. U h 7' b k . b .1 fi ld \!!I Field Inspection Non-conformance Summary se teL a ey to navigate etween uata entry Ie s . 10) (31.1.3) The component Technology's drives utilize R/e line side fuses rather than UL Listed fuses defined in the installation manual. 11) (26.5.1) Air filters are not provided over ventilation openings. 12) (49.2) The panel FLAis 584 amps, the large drive contained in this panel is marked 585 amps input. 13) (34.3.1) Square D drive controls two 1/2 HP motors. Each motor is not provided with separate overload protection. (7265 only) 14) (28.4.2 and 29.5.1) Separation of circuits not maintained. After data entry is complete, this form can be password protected for "comments" to avoid unauthorized changes. The gray shading in the data entry fields can also be removed using the "Forms" toolbar. Rev 2/25/03