Loading...
HomeMy WebLinkAbout0096232-Plumbing t...-."...... J...............)'~ o OSHKOSH ON THE WATER Job Address 1259 HARNEY AVE CITY of.; OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD No 96232 Owner HABITAT FOR HUMANITY Create Date 06/10/2002 Contractor DRUCKS PLUMBING Category 410 - Residential-I nterior Plan Bathtub 1 Shower 1 Ejector/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain 0 - - Whirlpool 0 Floor Drain 1 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0 Lavatory 2 Lndry Tray 0 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0 - Toilet 2 Lndry Stndp 1 Clothes Wshr 0 Ice Chest 0 FlrlWst Sink 0 Int Grease Trap 0 Res. Sink 1 Disposal 0 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0 - - Bar Sink 0 Dishwasher 0 Beer Tap 0 Sculry Sink 0 Wash Ftn 0 Water Heater 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 Urinal 0 - - - Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0 - - Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0 Use/Nature NSFR of Work Size Material Type # Conn. Type Sanitary Sewer o o o o o o o o o o Storm Sewer Water Service o o o o o Valuation $5,000.00 Issued By f( W\ Plan Approval $0.00 Permit Fees $66.00 Date 07/30/2002 o Permit Voided I In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. Signature Date Address PO BOX 355 Agent/Owner MENASHA WI 54952 - 0000 Telephone Number 426-2654 City of Oshkosh Inspection Services Division . POBox 1130 Oshkosh, WI 54903-1130 Phone: (920) 236-5050 Fax: (920) 236-5084 ~.;,-,.,. ~ ... ~ OfHKOfH ON THE WATER Plumbing Permit Application I hereby apply for a permit to do and install the following plumbing on the premises hereinafter described, the work to conform to the Wisconsin State Plumbing Code, in the perfolmance of which all parties hereto agree to and are. bound by said statutes. . Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, \ Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR If yOU are a contractor varticivating in the Permit Fee Account System and have adequate funds. check here if vou want this vrocessed through your account n Value (Including labor and materials) ''fJ1 r-crf) , Date 1,- J-Cj/'()~ Job Address Jd-S'1 /J~IVW:J- Owner ,j.J<III~/r-4"r rtftZ- /.f..tv"~rV'!!J Contractor ~Single Family DDuplex DMulti-Family Number of Fixtures: Bathtub Whirlpool Lavatory Toilet Res. Sink Bar Sink -L --.L ~ -L- Water Heater ~ o Gas 0 Elect~PwrVnt 'I Floor Drain ~ Shower Lndry Tray Lab Sink Plaster Sink Sterilizer Electric Contractor Use / Nature of Work D !2.--yu:r J~ S p;.,. '& 1 DRental DCommercial DIndustrial Lndry Standp I Dent. Oper. Shamp Sink Disposal Dip Well Flr/Wst Sink Dishwasher DrinkFtn Catch Basin Sump Pump I Wait.St. Wash Ftn Ejector/Grind Jtf -Jf:,- Cf"o. y: Ice Chest Urinal Water Softner Exam Sink Gar Drain Local Waste Sculry Sink Soda Disp _. Clothes Wshr Hand Sink Coffee Maker Bidet F Prep Sink. Ice Maker Beer Tap Serv Sink Site Drain Classrm Sink Int Grease Trap Roof Drain Surgeons Sink Ext Grease Trap Standp Rec Breakrm Sink OR DElectric Instalbition Verification form atta~bed (If Replacement) Sanitary Sew Storm Sewer Material PUG-- # Conn. Type Type (;;::'{V .77g-I'f~1 3/02 ,t ~). Fixture Listing . . Date: August 19,2002 --- / Name: DRUCKS PLBG Project: NSFR Street: Street: 1259 HARNEY City: City: Non Public Use Fixtures Hot Cold Total 1 Automatic Clothes Washer 1.00 1.00 1.50 1 Dishwashing Machine 1.00 .00 1.00 1 Hose Bib, 1/2" diameter .00 3.00 3.00 1 Kitchen Sink 1.00 1.00 1.50 1 Bathtub, lavatory and water closet - FT group 2.00 3.50 4.00 1 Shower Stall, lavatory and water closet FT - group 1.50 3.00 3.50 Public Use Fixtures Hot Cold Total .00 I .50 I .50 Q Ice Maker Total Water Supply Fixture Units 6.50 12.00 15.00 ~ ) 11.0 Gallon per minute demand of the building. Predominatly Flush Tank 59.3 Pressure available for uniform loss. For the table use - 60.0 Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4 Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value ofC 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 ,/"'"''') . It 44- WATER DISTRIBUTION HATASHEET Date: August 19,2002 .~ ) Name; DRUCKS PLBG Project: NSFR Street: Street: 1259 HARNEY City: City; 1. 11.0 Gallon per minute buiding demand, predominatly Flush Tan1e 2. 43.0 Low pressure at the Main in Street. 3. .0 Lb loss from a .0 ft difference in elevation from Main in Street to the Water Meter. 4a.--.& Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop. Pressure loss detemined using a C value of 150, inside diameter of .995 and a velocity of 4.5 ft per sec. 4b.~ Lb loss from a 60.0 ft 1 1/4" PE Tubing CTS ASTM 2737 AWWA C901 water service from the curb stop to the Water Meter. Pressure loss detemined using a C value of 150, inside diameter of 1.060 and a velocity of 4.0 ft per sec. 5. 1.8 Lb loss from a 3/4in Meter 6. 39.0 Lbs of pressure available at the Water Meter. This value is entered in (B) below. The (A) value listed below is determined by using the following formula, then rounding the result up. A= B-(C+D+E) x 100 F A. ~ Pressure av ail ab Ie for uniform loss (psill 00 feet of pipe). /~ i / B. ~ Lbs of pressure available at the Water Meter. C. ~ Pressure needed at the controlling fixture. TIS FAUCET D. ~ Lb loss resulting from a 12.0 ft difference in elevation from the Water Meter to the controlling fixture. E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture. F. 43.5 Ft Developed length from the 29.0 ft actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4 Actual 1. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value ofC 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 ," J / ~~ ;/-~".r: y; ? . . .' ~48114J1 ?tJ!b Hi1 /J14J1J/flt WATER CALCULATION WORKSHEET Information Needed for Water Service Sizing ~ l1 Demand of building in gallons per minute. ~ lD ~ Low pressure at main in street (or at external pressure tank). ~ You Must First Find the Available Press1.D"e After the Water Meter (or at building control valve). To obtain this pressure, you must: S ':) l. 10.7 2. 50Lb '" 3. to 4. ~ 5. (00" 6. 7. ----., Difference in eleva tion from main to meter (or external pressure tank to building control valve). Size of water meter (if applicable). Developed length from main to meter (or external pressure tank to building control valve). Find pressure loss due to friction in -L- inch water service. . L{3lf )(U, 8. 9. 4.J 3S Find pressure loss due to elevation, main to meter (or external pressure tank to building control valve). Multiply the difference in elevation by .434 p.s.i./ft. 2, CtJ Find pressure loss due to meter. (from manufacturer or AWWA). ~ 3 Subtract the lossz)fue to friction (Step 6), loss due to elevation (Step 7), and loss due to meter (Step 8) from the low main pressure (or low pressure at external pressure tank). This calculation is the available pressure after the water meter (or --..., at the building control valve). This answer is entered in Line B, below. ~ -IS Information Needed for Water Distribution Sizing ~s Using the foIIowing formula, find the pressure available for uniform loss (p.s.i/lOO' of pipe) A = B - ( C + D + E) x 100 F A. 3> B. ;.-ILf 11 c. 9 'l).~ D. /' Q -- E. ''1 t>1- XIOO F. l)~ .l, WHERE: 4% Pressure available for uniform loss (p.s.i./lOO' of pipe). 35 Available pressure after water meter (at the building control valve or low pressure at internal pressure tank). (See item 9, above). 8r.s:l Pressure needed at controIling fixture. IS~ fI( O(JY" 5l.. t51k'C__ h c-~. (.J) Difference in elevation between water meter (building control valve or internal pressure tank) and controlling fixture in feet -1.Lx .434 p.s.i./ft. 5. '- Pressure loss due to water softeners, water treatment devices, instantaneous water heaters and backflow preventers. Conventional water heaters usually do not have a pressure loss. \....,).) Developed length from water meter (building control valve or internal pressure tank) to controlling fixture in feet ~ x 1.5. ~ With pressure available for uniform loss, go to applicable table for distribution sizing. ~RD-6479 (R. 08/88) .A 1~",-toll~J:?.~L{~..~~.l-.!I-_~_._..~.. \ 11- 5 9 {~Q.r/Ve'-1 Au-<.. OSit.f{OJ~ ._-~~--, ---,. --.. .. .. . ---~-....__..._-_.__~._~w____~_..._;...__~....._.._, Nonp~liC I Public -" / ~ ' (-. --. e,,1'; ....'...v. Tyue Of Fi:xtu::e l'U' '''r 0 "",' ,> >' ~':::. T::lt...,l Total - ~'----r ':.::::" ~;'"'C:'':'':.'I...' -'-"'-"I"~-'-- - _~~_W~~k~::__, 1. " _,,,~_, 'dd __ ~L ~ _L_~ f It 0 )e t, ,(ob ~ '. I I I j.3 . -'--'--'-'~'---'---1' .-.... ..-----'----.~..-..~-.-.l...-.'.,..-- . ....-- , B (.\;+~ '-00-' : ~l4~~.;h L*.! <. ~:::,.':' ~/.>4 ~~~:~:~:t:~~I~L -~-i:t i.,.: ~,~~.~~+EL.-~-~:-.!l":~~ .. !~~t.,,- :), 1{1+~4V Si)VI< / } i I f I,$' /-r, r .. . --.-. ."1.... .... 1,.,_L!~ ; , I ! . .1........ ....__.. ....,__ ! ' I l I \ ",. '-i..-'-"~ "~----. i-- ; : 11 . ..-...,.......--------~__",.__'_,...._,....1....,,_...._.~_,,_"'.,_....__...._,_....,...~,__.._................,i.... ....' .. ; 1 .--......-...t. ...--.-..,..---- Flushometer Flush Tank f);~ ~shv / 5 , :; --_._~- .......--...-, !-----.-- ~ . .....---- ....~ ..~'...~.._.,."'._.-....-....,- .- .;~~. ...;;.._~..............,.....,'..,.; ." i ....._---,,^..~ _..... ~, ...........-,.......--............,. .......'-~.;.-.....,-_..-....--..."...~_......;.,. ....~--".... ~......,_._--_..--- .. ! l , 1 ...-.----"- ...-----..--.--t..--................-.--...........-....... ..... i , l.)ipe Siz'" G P " ~< ... 2--...... ..---.._.~!... ::!-r-_.E":i. "-T-YT...'.'.'''1 1/2 II to .5 .~l-_.._L._..~--.-"..I 3/4 " .Q._+ =,1 II? I 1 1I ! j ------t---- _. ~ i J 1 1 1/4 11 "'~c-~,..---..~----+_..-.-_l : t 1 1 1'/2 11 t I .! I ' 1 -.........---.-j-.--t-- I ! :2 II I f r ..~-.--~r-.-.....T-- :" 1/2 " =t------.i.-~'-..t-...- ----.--i--.-.-.-~.._+_,-__J J I_I ; j ~ \.1 S ~'V DIstribution Type ! .. I I .-.---- Service Building Type Demand G.P.M. '----- 'Ji2t I '" . /0',7 !PDh bV~'1{eNe.. D1stributlon Pipe .......~_....~.-._..._--- -r7PC. M..~ ...---..-.......,--- ~ Job Address 1259 HARNEY AVE HABITAT FOR HUMANITY , Pll:I'inbing Permit Work Card Permit Number 96232 Contractor DRUCKS PLUMBING '~"tegory 410 - Residential-Interior Plan _ .,htub 1 shower 1 EjeCt()r/Gri~a 0 'bipWell 0 Whirlpool 0 Floor Drain 1 Water Softner 0 Drink Ftn 0 Lavatory 2 Lndry Tray 0 Local Waste 0 Wait. St. 0 Toilet 2 Lndry Stndp 1 Clothes Wshr 0 Ice Chest 0 - Res. Sink 1 Disposal 0 Bidet 0 Exam Sink 0 Bar Sink 0 Dishwasher 0 Beer Tap 0 Sculry Sink 0 - 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 - 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 rSFR Size Material Type " Type~Fnar' . ~-'''''f!''f, o o o o o Insp'ector WJ (Chip) Callies 111/ 0 V FPl'ep Sink Serv Sink Shamp Sink FlrlWst Sink Catch Basin Wash Ftn Urinal Standp Rec Ice Maker # Conn. Type o o o o o o o o o o Create Date 06/10/2002 Value $5,000.00 o o o o o 6 o o o o o o o o Gar Drain Soda Disp Coffee Maker Int Grease Trap Ext Grease Trap 1:'- $' A ft/ .. Access:.' , ' '1lOpen Wedn,Th~rs &FridaY~-H-;'dlike tobepresent: ,',;",', Ready b~teitime:~i'S"'AM' ,'. Req~estedBY:HABrfATFOR HUMANITY , 0 Reinspect Fee 0 Fee Waived 'tJ"""'Reinspect Fee Paid 1259 HARNEY AVE "HABITAT FOR HUMANITY I Plumbing Pe'-rmit Work Card Permit Number 96232 Contractor DRUCKS PLUMBING Create Date 06/10/2002 410- Residential-Interior Plan Value $5,000.00 .htub ~ Shower ~ Ejector/Grind -1Q Dip Well 0 F Prep Sink 0 Gar Drain 0 Whirlpool 0 Floor Drain -b Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0 Lavatory 112 Lndry Tray 0 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0 Toilet ~ Lndry Stndp ~ Clothes Wshr 0 Ice Chest 0 Flr/Wst Sink 0 Int Grease Trap 0 Res. Sink ~ Disposal 0 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0 - Bar Sink 0 Dishwasher 0 Beer Tap 0 Sculry Sink 0 Wash Ftn 0 Water Heater ~ Sump Pump --L1 Dent. Oper. 0 Hand Sink 0 Urinal 0 Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0 - 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0 rSF" Size Material Type # o o o o o Conn. Type GWH ~ rAJ4cw V;lirfJ!; o o o o o F f?-/'I/Oir Telephone Number: .Re~dY Datefrime: ~iJ:l~~ted By: . DRUCKS PLUMBING- Kurt Hatfield o Reinspect Fee 0 ee alve Reinspect Fee Paid .. . . . 'cc' ~ :100 . . , ,." , , , '~f ' , 00 , , , . 00 ,c,c, , , , , , " , , , , -- , , , 00 , ., , , ,. 'c' OOc' ",' .' , . ',- '-'c'c._,M c" ,,_,'c. ' c~~ ~ 0 K I ~ d- \- t~4i)S to ~