HomeMy WebLinkAboutPlumbing ZZ4-287-1107-P
~
e
OSHKOSH
ON THE WATER
Oshkosh Plan Approval Form
Job Address
631 HAZEL ST
Approval Number
2205
Approval Type Plumbing
Submitter's Name PAT O'NEILL
Address
Plan ZZ4-287-1107-P
Owner Name
HEALTH CARE REIT INC
Address 1 SEA GATE 1500
TOLEDO
OH
43603
o
Type of Plan BUILDING INTERIOR CONVERSION TO APARTMENTS
Fee
$480.00
Date Received
11/19/2007
Date Approved 11/26/2007
't:.;~
~
OJHKOJH
City of Oshkosh
Inspection Services
215 Church Ave., PO Box 1130
Oshkosh, WI 54902-1130
(920) 236-5052 (920) 236-5184 FAX
..~
ON THE WATER
November 26, 2007
0' Neill Enterprises Inc.
522 W 6th Ave.
Oshkosh, WI. 54902
Ref: Plumbing Plan Approval:
Bella Vista-Interior Plumbing
631 Hazel St, Oshkosh, WI
Plan ID# ZZ4-287-1107-P
Dear Sirs,
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin
Administrative Code, the plumbing plans. and specifications are approved contingent upon
compliance with the stipulation(s) noted below.
1. All plumbing fixtures, appliances and appurtenances with 3/8" or larger inlet
openings and with solenoid actuated quick closing valves shall be provided with
water hammer arrestors. COMM 82.40(8)(f)
2. Water supply systems and the connection of each plumbing fixture, piece of
equipment, appliance or nonpotable water supply piping system shall be designed,
installed and maintained in such a manner to prevent the contamination of water
supplies by means of cross connections. COMM 82.41(3)
3. Air Admittance Valves must be installed in accordance with the manufacturer's
printed instructions, system approval, plan approval and Wisconsin Administrative
Code. AA V's must hold a pressure equal to one-inch water column for five minutes
after installation or immediately prior to installation.
4. Piping hangers and anchors shall be securely attached to the building's structure at
intervals to support the piping and its contents, but not at intervals greater than
those specified in Table 82.60. COMM 82.60(2)(a)
5. All changes or modifications made to plumbing plans and specifications, which have
been granted approval, shall be submitted to the Department or Agent for
examination. All changes and modifications shall be approved in writing prior to the
installation of the plumbing per COMM 82.20(8). Available incoming water pressure
shall be field verified in order to properly size water distribution piping, water
calculation worksheet submitted shows an incoming pressure of 71 PSI with an "A"
value of 6.
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. A new application accompanied by full examination
fees shall be filed and an updated approval received before work may commence.
'9"
~;
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or
any damage that may result in or after installation. The City of Oshkosh reserves the right to
order changes or additions should conditions arise making this necessary.
It shall be necessary for the installing plumber to obtain a plumbing permit from the City of
Oshkosh before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Paul Wolf,
Plumbing Inspector