ON THE WATER
November 21,2007
Clark Meyer
Omnni Associates
One Systems Drive
Appleton, WI 54914
Rick Dworeck
Dairy Queen - Oshkosh
510 W Murdock Ave.
Oshkosh, WI 54901
Site: Plan Number: ZZ6-2177-1007
Dairy Queen - Oshkosh
510 W Murdock Ave
Oshkosh WI 54901
For:
Description: Add'itioiland alterations
Object Type: Building only
Class of Construction: VB - 2944 Sq Ft.; Unsprinklered
Occupancy: A: Assembly, S: Storage - Non separated Use
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Hem(s) I Conditions:
· IBC 716.2.2 Concealed wall spaces. Fire blocking shall be provided in concealed spaces of stud walls and
partitions, including furred spaces, at the ceiling and floor levels and at 10-foot (3048 tnm) intervals both
vertical and horizontal. Revised Wall section B / A500 still does not show requiredfire blocking at
ceiling level. Please make sure fire blocking is properly installed.
· IECC 802.2.7 Slabs on grade. The minimum thermal resistance (R-value) ofthe insulation around the
perimeter of the slab floor shall be as specified in Table 802.2(1), 802.2(2), 802.2(3) or 802.2(4). Provide
R-value for the thermal break material specified as 45# felt in section 1 / S200.
· 1202.2 Attic spaces. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly
to the underside of roof framing member shall have cross ventilation for each separate space by ventilating
openings protected against the entrance ofrain and snow. Blocking and bridging shall be arranged so as
not to interfere with the movement of air. A minimum of 1 inch (25 mm) of air space shall be provided
between the insulation and the roof sheathing. The net free ventilating area shall not be less than 1/150 of
the area of the space ventilated, with 50 percent of the required ventilating area provided by ventilators
located in the upper portion of the space to be ventilated at least 3 feet (914 mm) above eave or cornice
vents with the balance of the required ventilation provided by eave or cornice vents. Ventilation of the
space above the fiberglass attic insulation is required to be vented per the requirements of this section.
· Note: Per discussion with general contractor, there is the possibility that the fiberglass insulation maybe
substituted with foam insulation on the roof deck. If this change is made, verify compliance with Chapter
26 requirements for a thermal barrier or meeting the requirements of the exception for blocked joints on
wood structural sheathing. Please contact this office to advise if this change will be made, so we can
review proposed installation for code compliance.
\\OSHKOSHMISFS\Dc~partmcms\inspc('tioll;;\Plan Rcview\Commcrcial Finn Review 2007\.ZZ6-2177-1.007 51 I,) W Murdock :\vc Bldg Only,doe
Page 1 of2
· Comm 61.30(3) /IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment.
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
SUBMIT:
· Comm 61.30(3) This review does not include Truss components. Submit, prior to installation one set of
properly signed and sealed truss plans, and completed SBD-118 application form and fee
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
rian Noe
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
Fee Required $
Fee Received $
320.00
320.00
Balance Due $
0.00
cc: Property file
\\OSHKOSHM ISFS\Dcpmtmcnls\!nspcction;;\Pbn Rcvicw\Commcrcial P1an Review 2()()7'ZZ6-21:7 -100: 51 () W Murdod: A V(' Bldg ()111y,doc