Loading...
HomeMy WebLinkAbout2007-Building (roof) ~.. OSHKOSH ON THE WATER Job Address 1424 S MAIN ST CITY OF OSHKOSH No 127840 BUILDING PERMIT - APPLICATION AND RECORD Owner DONALD B CONDON ETAL ESTATE Create Date 11/15/2007 Designer Contractor W J WOODRUFF ROOFING CONTRACTORS It Category 232 - Alteration Stores & Customer Service Plan Type . Building o Sign o Canopy o Fence o Raze Zoning Class of Const: Size Unfinished/Basement Sq. Ft. Rooms Height Ft. o Projection I Finished/Living Sq.Ft. Sq.Ft. Bedrooms Stories Canopies Garage Baths Signs Foundation 0 Poured Concrete 0 Floating Slab o Concrete Block 0 Post o Pier . Other o Treated Wood Occupancy Permit Not Required Occupancy Fee $0.00 Flood Plain Height Permit # Dwelling Units o # Structures o Park Dedication Use/Nature ommericial/lndustrial- Reroof- Tear off existing, install new insulation board and EPDM membrane roof. UL assembly 292. of Work HV AC Contractor Plumbing Contractor Electric Contractor $37,280.00 Plan Approval $0.00 Permit Fee Paid $202.00 Park Dedication $0.00 Fees: Val Issued By: Date 11/15/2007 Final/O.P. 00/00/0000 o Permit Voided I Parcelld # 0304810000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure ecessary app~ov1lS bef e s such activity. Signature ~ _ tA.A::. Date J /--/s-07 Address PO BOX 763 FOND DU LAC WI 54936 - 0763 Telephone Number 920-922-3110 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. C-Store 1424 SHain St. Oshkosh WI 54901 Contract price $ 37,280.00 Project over metal roof deck - existing roofing (gravel surfaced BUR) and roof insulation will be removed and disposed of. Over the existing metal roof deck - new 2.0" polyiso roof irisulation and new 60 mil EPDM roofing. Owner Condon Companies 126 E Jackson Ripon WI 54971 I LtB s-y # ~ 'd-O fOOD l1{1 3 ~ ~r'~~ JJ1 -->- 2cq<'L n,,~ IX ,( b '- eX 'f ~,~ e. ~ WAIHliIllGS, AND UMnA'~OIS ~ CARLISLE (O'~~'UII(ES ASTM C1289-06, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) International Building Code (IBC) Section 2603 NOTE: Please be aware the Federal Specification HH-I-1972/GEN has been replaced, U~DIIW!lnllS UIOU'OR~IS,\!, 11(" Component of Class A Roof Systems (UL 790) Hourly Rated P series roof assemblies (UL 263) P 225, 230, 259, 302, 303, 508, 510,514,519,701,710,713,717,718, 719, 720, 722, 723, 727, 728, 729, 730, 732,734,735,739,741,742,743,818, 819,824, 827, Insulated me nos, 120, 12 H-Shield clas R18846 MU'rU.llIESURCI FM Class 1 approval for steel roof-deck constructions, (FM 4450) FM 4470 (Subject to the conditions of approval described in Roofnav,com) FlORIDA BUilDING CODEAPPR01lll Fl#1296 MIAMI-DADE COUNlY, RORIOA NOA NO: 04-1018.01 ~SS/F~ Foamed plastic as roof deck construction material with resistance to an C:>-~Q internal fire exposure only for use in construction no,(s) 120 and 123, C " L US See UL Directory of Products Certified for Canada and UL Roofing Materials and Systems Directory, 99DL . t:1~'1:::I3n''''''r!1:1 PI Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof- covering material. Carlisle will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specific details, or refer to PIMA Technical Bulletin No, 109: Storage & Handling Recommendations for Polyiso Roof Insulation. Compressive ~trength Dimensional ASTM D 1621 ASTM 1289-06 ASTM D 2126 20 psi' minimum (1.~~.~~a,grilde..?)_ 2% linear change Moisture Vapor < 1 perm 250' F Service Temperature :!\Iso_il~ailab.le in 25_psirTlinirTl~I11., Gr.ild.~3___ OmiER "ll~SO PROIUt7S If 4 SECURSHIELD POLYISO BONDED TO COATED GLASS FACER HP-CG POLYISO BONDED TO COATED GLASS FACER HP-F POL YISO BONDED TO FOIL HP-NB POL YISO BONDED TO ORIENTED STRAND BOARD HP-WF POL YISO BONDED TO WOOD FIBERBOARD TAPERED HP-CG TAPERED POL YISO BONDED TO COATED GLASS FACER TAPERED HP-H TAPERED POLYISO TAPERED HP-H-WF TAPERED POL YISO BONDED TO WOOD FIBERBOARD 800-4~SYNTEC P.O. Box 7000 Carlisle, PA 17013 - Fax: 717-245-7053 www.carlisle-syntec.com Carlisle is a trademark of Carlisle. REPRINT CODE: 600491 - "HP-H Polyiso Product Data Sheet" - 082007 @ 2007 Carlisle. Carlisle SynTec CARLISLE PRO~U(l HP-H is a rigid roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to fiber-reinforced facers. fll.llJRtS Mill HP-H polyiso insulation provides the highest R-value per inch of commercially available insulation products. Environmentally friendly construction with 0% ozone-depleting components and CFC free Approved for direct application to steel decks Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x 2440mm) panels in thickness of 1" (25mm) to 4.0" (102mm) Available in two grades of compressive strengths per ASTM C1289-05a, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) Constructions requiring FM Class 1 and UL Class A ratings Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) * Long Term Thermal Resistance Foam Core Values are based on A5TM C1289-06 and CAN/ULC 5770 which provides for a 15-year time-weighted average. All PIMA members have adopted this advanced standard for R-values measurement as of 1/1/03. iilITAUA1101lt . BALLASTED SINGLE-PLY SYSTEMS Each HP-H panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to the manufacturer's specifications. MECHANICALLY ATTACHED SINGLE-PLY SYSTEMS . Each HP-H panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to the manufacturer's specifications. FULLY ADHERED SINGLE PLY Each HP-H panel must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to manufacturer's specifications. HP-H 4' xB' panels can be secured to the roof deck with Carlisle's FAST adhesive technology. HP-H 4' x 4' (metric) panels may be adhered to prepared concrete deck with a full mopping ofType III or IV asphalt. BOO-4-SYNTEC' P.O. Box 7000 Carlisle, PA 17013 Fax: 717-245-7053 www.carlisle-syntec.com Carlisle SynTec 'l' 3 MATERIALS AND SYSTEMS DIRECTORY ~'z~ ;uardian-Lok" ,earn Plus" pused with anel rib (Item spacer (Item' :lips are ' panel sides steners (Item JO-MS Clip" ticulating mt, rein- he same'con- forcement cut Metal rein: ~gments' with o-M$"'. hi Transmit- lips to purlin hex~lwad, asher. ' 3/8 in. hex- ive (5) fas- I with the in a 3-6-6-3 :ond slant oneaddi- sides of one steel tipper ' t fastener 2-4 In. pat- .acking'plate ). Screws are :hree screws rib with two !ffi thickness ation, 6 in. :ers or 5 in. thermal purlin end laps and in. wide !ction to be I. Upper Un 18 MSG section Five 5/16 : shown) - gs on both leI (Item nent build- :ngth). g Materials ROOF DECK CONSTRUCTIONS (TGKX) Construction No. 289 Fire Classified Uplift Not Investigated 1. Supports - Structural steel or 'other materials acceptable to authorities having jurisdiction. . 2. Steel Deck- No. 22 MSG min, 1-112 in. min depth, unperforated, coated steel, fluted on 6 in. centers. Welded or mechanicaIly fastened to supports in accordance with deck manufacturer's recommendations. 3. Foamed Plastic - MinI.2in. thick polyisocyanurate foamed plastic insulation. Classified by Underwriters Laboratories Inc. under,"Foamed Plastic" (TJBX). The material is loosely laid over the steel deck. 4. Foamed Plastic- Rigid polystyrene inslliation Classified by Under- writers Laboratories Inc. under "Foamed Plastic" (IJBX). Max thickness to be 6 in. The insulation is loosely laid over the polyisocyanurate foamed plastic inslliation. , OWENS CORNING SPECIALTY & FOAM PRODUCTS "':'Foamlliar 150 or 250. 5. RoofCoveririg" -"- Any Idose laid (ballasted) single ply membrane sys- tem Classified by Underwriters Laboratories Inc. as Roofing Systems (TGFU)..Membrane may be placed beneath, loose laid on top or sand" wiched between layers of rigid polystyrene foarn plastic insulation (Item 4). Authorities having jurisdiction should be consllited as to' which elass.of roof covering will be acceptable in each location. SA. Roof Covering' ~ (Not shown)-Any single ply membrane system fully adhered or mechanically fastened system Classified by Underwrit- ers Laboratories Inc. as Roofing Systems (TGFU). 5B. Roof Covering".:..... (Not showri)-Any built-up, cold.application or single ply materials Classified by Underwriters Laboratories Inc. as Roofing Systems (TGFU). 6. Ballast.:..... River bottom stone, 3/4 to 1-1/2 in. diameter; spread over the roof coverii1.g at a rate of 1000 lb per sq. . Refer to GenerafInformation, Roof Deck Constructions (Roofing Materi- als and Systems Directory) for items not evaluated. "Bearing the UL Classification. Mark , i /G..---.--::'-\ ConstructionN . 292 .....-/ l,Iplift ...:.. Not In.Je~ti . ed- . Fire Classified 1. Supports - Structural steel or other materiqlsacceptable to authorities having jurisdiction. .,' , . 2. 'Steel Deck -' No. 22 MSG min, 1-1/2 in. min depth, unperforated, coated steel, fluted on 6 in. .centers. Welded or mechanicaIly fastened to supports in accordance with deck manufacturers recommendations. 3. Foamed Plastic" -' Min 1.2 in. thick Polyisocyanurate inslliation. The material is to be loosely laid, mechanically fastened or adhered with steep asphalt at a rate of 12 to 15 lb per 100 sq ft to the steel deck. FIRESTONE BUILDING PRODUCTS CO, DIV OF ' BFS DIVERSIFIED PRODUCTS L L C -"IS095+FK", "IS095+GL", "IS095+GW", "Rhoflex Isocyanurate FK", "Rhof- lex Isocyanurate GL" or "Rhoflex Isocyanurate GW" . 4. Foamed Plastic* - Ridged expanded polystyrene (EPS) Classified by Underwriters Laboratories Inc. under "Foamed Plastic" (BRYX). Loosel~ lai? over the Polyisocyanurate insulation (Item 3). Max thick- ness 6 Ill.' . 5. Roof Covering* - Any single ply membrane Classified by Underwrit- ers Laboratories Inc. has "Membrane for Roofing Systems" as described in the Roofing Materials and Systems Directory under the category , TGFU. Authorities having jurisdiction shollidbe consllited concerning which class roof covering Will be acceptable in each location., IR THEUL MARK ON PRODUCT ,/ 2003 ROOFING MAT ROOF DECK CONSTRUCTIONS (TGKX) Membrane may be either loosely laid over instilation and coverE ballast or membrane may be mechanically fastened or fully adhert a min thickness of 1/2 in. perlite or wood fiber insula?on in.accc with the Classification established from membrane/msulation . systems' indicated under. the category TGFU. Refer to General Information, Roof Deck Constructions, Roofing M and Systems Directory, for Items not evaluated. "Bearing the UL Classification Mark Construction No. 293 Uplift - Class 15 Fire Not Investigated 1. Framing System - The franling system identified as :'HD8900 1 Hung Framing System" used to support the soffit consISts of the lowing Classified Components:. . 1A. Main Runners*-Nom 12 ft long, spaced 48 in. OC. SUPF by hanger assemblies (Item 2) at a spacing of 2 ft OC~ ARMSTRONG WORLD INDUSTRIES INC -"HD'~ "HD 8906" IB. cross Tees* - Nom 4 ft long, installed perpendiclliar to m runners and spaced 24 in. oe. , ARMSTRONG WORLD INDUSTRIES INC -"XL 8~ Ie. Channel Molding*- 15/16 in. by 1-1/2 in. deep, nom lIt in. long. Fastened to waIls with No. 8-18 by 1(2 Ill. lo~g sel drilling, steel Phillips head screws at appropnate spacmg. ARMSTRONG WORLD INDUSTRIES INC -"7838' 10. StiffenirigLeg" - Fabricated from 0.034 in; thick coated st Formed to slip over hanger wire. Length to vary. ARMSTRONG WORLD INDUSTRIES INC-"STL-J 2. Hanger Assembly-Located at each main runner~cross tee, inlE tion. Consisting of a hanger eyelet or other appropnate connector hanger wire and a Class~ed "?tiff Leg". (Item No. 10): Len~ to with max length to be 30 Ill. Dlam of WlIe to be 0.105 Ill. nun. 3. Gypsum Board" - Supplied in sheets, 48 in. Wide, by, mi? 8 ft .10 and min 5/8 in. thick. Wallboard fastened to cross tees Wlth Phill bugle headed steel screws 1 in. long spaced 6 in. on c~ter. 4. Supports - Any structural steel or' wood members SIZed and Spi as required to support hang~r assembly (Item 2). . Refer to General Information~ Roof Deck Constructions, (Roofing ~ als and Systems Directory) for items not evaluated. "Bearing the UL Classification Mark Construction No. 293A Uplift - Class 15 Fire Not Investigated 1. Framing System - The framing system identified as "7301 Lay- Framing System" used to support the soffit, consists of the f?llow: Classified Components: . c IA. Main Runners* - Nominal 12 ft long, spaced 48 Ill. OC . _ ported by hanger assemblies (Item 2) at a spacing of 2 ft OC ARMSTRONG WORLD INDUSTRIES INC -"7301" 1B. Cross Tees* - Nominal 4 ft long, installed perpendiclliar t< main runners and spaced 2 it OC (ML-6148). LOOK FOR 1