HomeMy WebLinkAbout2007-Building (roof)
~..
OSHKOSH
ON THE WATER
Job Address 1424 S MAIN ST
CITY OF OSHKOSH No 127840
BUILDING PERMIT - APPLICATION AND RECORD
Owner DONALD B CONDON ETAL ESTATE Create Date 11/15/2007
Designer
Contractor W J WOODRUFF ROOFING CONTRACTORS It
Category
232 - Alteration Stores & Customer Service Plan
Type
. Building
o Sign
o Canopy
o Fence
o Raze
Zoning
Class of Const:
Size
Unfinished/Basement Sq. Ft.
Rooms
Height
Ft.
o Projection I
Finished/Living
Sq.Ft.
Sq.Ft.
Bedrooms
Stories
Canopies
Garage
Baths
Signs
Foundation 0 Poured Concrete 0 Floating Slab
o Concrete Block 0 Post
o Pier . Other
o Treated Wood
Occupancy Permit Not Required
Occupancy Fee
$0.00 Flood Plain
Height Permit
# Dwelling Units
o
# Structures
o
Park Dedication
Use/Nature ommericial/lndustrial- Reroof- Tear off existing, install new insulation board and EPDM membrane roof. UL assembly 292.
of Work
HV AC Contractor
Plumbing Contractor
Electric Contractor
$37,280.00 Plan Approval
$0.00 Permit Fee Paid
$202.00 Park Dedication
$0.00
Fees: Val
Issued By:
Date 11/15/2007
Final/O.P. 00/00/0000
o Permit Voided I
Parcelld # 0304810000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure ecessary app~ov1lS bef e s such activity.
Signature ~ _ tA.A::. Date J /--/s-07
Address PO BOX 763
FOND DU LAC
WI 54936 - 0763 Telephone Number 920-922-3110
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
C-Store
1424 SHain St.
Oshkosh WI 54901
Contract price
$ 37,280.00
Project over metal roof deck - existing roofing (gravel surfaced BUR)
and roof insulation will be
removed and disposed of.
Over the existing metal roof deck - new 2.0" polyiso roof irisulation
and new 60 mil EPDM roofing.
Owner
Condon Companies
126 E Jackson
Ripon WI 54971
I LtB
s-y
#
~ 'd-O fOOD
l1{1 3
~
~r'~~ JJ1 -->- 2cq<'L
n,,~ IX ,( b '- eX 'f ~,~ e. ~
WAIHliIllGS, AND UMnA'~OIS
~
CARLISLE
(O'~~'UII(ES
ASTM C1289-06, Type II, Class 1, Grade 2
(20 psi), Grade 3 (25 psi)
International Building Code (IBC)
Section 2603
NOTE: Please be aware the Federal Specification
HH-I-1972/GEN has been replaced,
U~DIIW!lnllS UIOU'OR~IS,\!, 11("
Component of Class A Roof Systems
(UL 790)
Hourly Rated P series roof assemblies
(UL 263) P 225, 230, 259, 302, 303, 508,
510,514,519,701,710,713,717,718,
719, 720, 722, 723, 727, 728, 729, 730,
732,734,735,739,741,742,743,818,
819,824, 827,
Insulated me
nos, 120, 12
H-Shield clas
R18846
MU'rU.llIESURCI
FM Class 1 approval for steel roof-deck
constructions, (FM 4450)
FM 4470
(Subject to the conditions of approval described in
Roofnav,com)
FlORIDA BUilDING CODEAPPR01lll Fl#1296
MIAMI-DADE COUNlY, RORIOA NOA NO: 04-1018.01
~SS/F~ Foamed plastic as roof deck construction material with resistance to an
C:>-~Q internal fire exposure only for use in construction no,(s) 120 and 123,
C " L US See UL Directory of Products Certified for Canada and UL Roofing
Materials and Systems Directory, 99DL
.
t:1~'1:::I3n''''''r!1:1
PI
Insulation must be protected from open flame and
kept dry at all times. Install only as much insulation
as can be covered the same day by completed roof-
covering material. Carlisle will not be responsible for
specific building and roof design by others, for
deficiencies in construction or workmanship, for
dangerous conditions on the job site or for improper
storage and handling. Technical specifications
shown in this literature are intended to be used as
general guidelines only and are subject to change
without notice. Call Carlisle for more specific details,
or refer to PIMA Technical Bulletin No, 109: Storage
& Handling Recommendations for Polyiso Roof
Insulation.
Compressive
~trength
Dimensional
ASTM D 1621
ASTM 1289-06
ASTM D 2126
20 psi' minimum
(1.~~.~~a,grilde..?)_
2% linear change
Moisture Vapor
< 1 perm
250' F
Service Temperature
:!\Iso_il~ailab.le in 25_psirTlinirTl~I11., Gr.ild.~3___
OmiER "ll~SO PROIUt7S If
4 SECURSHIELD POLYISO BONDED TO COATED
GLASS FACER
HP-CG POLYISO BONDED TO COATED GLASS FACER
HP-F POL YISO BONDED TO FOIL
HP-NB POL YISO BONDED TO ORIENTED STRAND BOARD
HP-WF POL YISO BONDED TO WOOD FIBERBOARD
TAPERED HP-CG TAPERED POL YISO BONDED TO
COATED GLASS FACER
TAPERED HP-H TAPERED POLYISO
TAPERED HP-H-WF TAPERED POL YISO BONDED TO
WOOD FIBERBOARD
800-4~SYNTEC P.O. Box 7000 Carlisle, PA 17013 - Fax: 717-245-7053 www.carlisle-syntec.com
Carlisle is a trademark of Carlisle.
REPRINT CODE: 600491 - "HP-H Polyiso Product Data Sheet" - 082007 @ 2007 Carlisle.
Carlisle SynTec
CARLISLE
PRO~U(l
HP-H is a rigid roof insulation panel composed of a
closed-cell polyisocyanurate foam core bonded on
each side to fiber-reinforced facers.
fll.llJRtS Mill
HP-H polyiso insulation provides the highest
R-value per inch of commercially available
insulation products.
Environmentally friendly construction
with 0% ozone-depleting components
and CFC free
Approved for direct application to steel
decks
Available in 4'x4' (1220mm x 1220mm) and
4'x8' (1220mm x 2440mm) panels in
thickness of 1" (25mm) to 4.0" (102mm)
Available in two grades of compressive
strengths per ASTM C1289-05a, Type II,
Class 1, Grade 2 (20 psi), Grade 3 (25 psi)
Constructions requiring FM Class 1 and UL
Class A ratings
Single-Ply Roof Systems (Ballasted,
Mechanically Attached, Fully Adhered)
* Long Term Thermal Resistance Foam Core Values are based
on A5TM C1289-06 and CAN/ULC 5770 which provides for a
15-year time-weighted average. All PIMA members have adopted
this advanced standard for R-values measurement as of 1/1/03.
iilITAUA1101lt .
BALLASTED SINGLE-PLY SYSTEMS
Each HP-H panel is loosely laid on the
roof deck. Butt edges and stagger joints of
adjacent panels. Install the roof membrane
according to the manufacturer's
specifications.
MECHANICALLY ATTACHED
SINGLE-PLY SYSTEMS .
Each HP-H panel must be secured to the
roof deck with fasteners and plates
(appropriate to the deck type). Butt edges
and stagger joints of adjacent panels.
Install the roof membrane according to the
manufacturer's specifications.
FULLY ADHERED SINGLE PLY
Each HP-H panel must be secured to the
roof deck with fasteners and plates
(appropriate to deck type). Butt edges
and stagger joints of adjacent panels.
Install the roof membrane according to
manufacturer's specifications.
HP-H 4' xB' panels can be secured to
the roof deck with Carlisle's FAST adhesive
technology.
HP-H 4' x 4' (metric) panels may be
adhered to prepared concrete deck with
a full mopping ofType III or IV asphalt.
BOO-4-SYNTEC' P.O. Box 7000 Carlisle, PA 17013 Fax: 717-245-7053 www.carlisle-syntec.com
Carlisle SynTec
'l'
3 MATERIALS AND SYSTEMS DIRECTORY
~'z~
;uardian-Lok"
,earn Plus"
pused with
anel rib (Item
spacer (Item'
:lips are '
panel sides
steners (Item
JO-MS Clip"
ticulating
mt, rein-
he same'con-
forcement cut
Metal rein:
~gments' with
o-M$"'.
hi Transmit-
lips to purlin
hex~lwad,
asher. '
3/8 in. hex-
ive (5) fas-
I with the
in a 3-6-6-3
:ond slant
oneaddi-
sides of one
steel tipper '
t fastener
2-4 In. pat-
.acking'plate
). Screws are
:hree screws
rib with two
!ffi thickness
ation, 6 in.
:ers or 5 in.
thermal
purlin
end laps
and
in. wide
!ction to be
I. Upper
Un 18 MSG
section
Five 5/16
: shown) -
gs on both
leI (Item
nent build-
:ngth).
g Materials
ROOF DECK CONSTRUCTIONS (TGKX)
Construction No. 289
Fire Classified
Uplift Not Investigated
1. Supports - Structural steel or 'other materials acceptable to authorities
having jurisdiction. .
2. Steel Deck- No. 22 MSG min, 1-112 in. min depth, unperforated,
coated steel, fluted on 6 in. centers. Welded or mechanicaIly fastened to
supports in accordance with deck manufacturer's recommendations.
3. Foamed Plastic - MinI.2in. thick polyisocyanurate foamed plastic
insulation. Classified by Underwriters Laboratories Inc. under,"Foamed
Plastic" (TJBX). The material is loosely laid over the steel deck.
4. Foamed Plastic- Rigid polystyrene inslliation Classified by Under-
writers Laboratories Inc. under "Foamed Plastic" (IJBX). Max thickness
to be 6 in. The insulation is loosely laid over the polyisocyanurate
foamed plastic inslliation. ,
OWENS CORNING SPECIALTY &
FOAM PRODUCTS "':'Foamlliar 150 or 250.
5. RoofCoveririg" -"- Any Idose laid (ballasted) single ply membrane sys-
tem Classified by Underwriters Laboratories Inc. as Roofing Systems
(TGFU)..Membrane may be placed beneath, loose laid on top or sand"
wiched between layers of rigid polystyrene foarn plastic insulation
(Item 4). Authorities having jurisdiction should be consllited as to'
which elass.of roof covering will be acceptable in each location.
SA. Roof Covering' ~ (Not shown)-Any single ply membrane system
fully adhered or mechanically fastened system Classified by Underwrit-
ers Laboratories Inc. as Roofing Systems (TGFU).
5B. Roof Covering".:..... (Not showri)-Any built-up, cold.application or
single ply materials Classified by Underwriters Laboratories Inc. as
Roofing Systems (TGFU).
6. Ballast.:..... River bottom stone, 3/4 to 1-1/2 in. diameter; spread over
the roof coverii1.g at a rate of 1000 lb per sq. .
Refer to GenerafInformation, Roof Deck Constructions (Roofing Materi-
als and Systems Directory) for items not evaluated.
"Bearing the UL Classification. Mark , i /G..---.--::'-\
ConstructionN . 292 .....-/
l,Iplift ...:.. Not In.Je~ti . ed- .
Fire Classified
1. Supports - Structural steel or other materiqlsacceptable to authorities
having jurisdiction. .,' , .
2. 'Steel Deck -' No. 22 MSG min, 1-1/2 in. min depth, unperforated,
coated steel, fluted on 6 in. .centers. Welded or mechanicaIly fastened to
supports in accordance with deck manufacturers recommendations.
3. Foamed Plastic" -' Min 1.2 in. thick Polyisocyanurate inslliation. The
material is to be loosely laid, mechanically fastened or adhered with
steep asphalt at a rate of 12 to 15 lb per 100 sq ft to the steel deck.
FIRESTONE BUILDING PRODUCTS CO, DIV OF '
BFS DIVERSIFIED PRODUCTS L L C -"IS095+FK",
"IS095+GL", "IS095+GW", "Rhoflex Isocyanurate FK", "Rhof-
lex Isocyanurate GL" or "Rhoflex Isocyanurate GW" .
4. Foamed Plastic* - Ridged expanded polystyrene (EPS) Classified by
Underwriters Laboratories Inc. under "Foamed Plastic" (BRYX).
Loosel~ lai? over the Polyisocyanurate insulation (Item 3). Max thick-
ness 6 Ill.' .
5. Roof Covering* - Any single ply membrane Classified by Underwrit-
ers Laboratories Inc. has "Membrane for Roofing Systems" as described
in the Roofing Materials and Systems Directory under the category ,
TGFU. Authorities having jurisdiction shollidbe consllited concerning
which class roof covering Will be acceptable in each location.,
IR THEUL MARK ON PRODUCT
,/
2003 ROOFING MAT
ROOF DECK CONSTRUCTIONS (TGKX)
Membrane may be either loosely laid over instilation and coverE
ballast or membrane may be mechanically fastened or fully adhert
a min thickness of 1/2 in. perlite or wood fiber insula?on in.accc
with the Classification established from membrane/msulation
. systems' indicated under. the category TGFU.
Refer to General Information, Roof Deck Constructions, Roofing M
and Systems Directory, for Items not evaluated.
"Bearing the UL Classification Mark
Construction No. 293
Uplift - Class 15
Fire Not Investigated
1. Framing System - The franling system identified as :'HD8900 1
Hung Framing System" used to support the soffit consISts of the
lowing Classified Components:. .
1A. Main Runners*-Nom 12 ft long, spaced 48 in. OC. SUPF
by hanger assemblies (Item 2) at a spacing of 2 ft OC~
ARMSTRONG WORLD INDUSTRIES INC -"HD'~
"HD 8906"
IB. cross Tees* - Nom 4 ft long, installed perpendiclliar to m
runners and spaced 24 in. oe.
, ARMSTRONG WORLD INDUSTRIES INC -"XL 8~
Ie. Channel Molding*- 15/16 in. by 1-1/2 in. deep, nom lIt
in. long. Fastened to waIls with No. 8-18 by 1(2 Ill. lo~g sel
drilling, steel Phillips head screws at appropnate spacmg.
ARMSTRONG WORLD INDUSTRIES INC -"7838'
10. StiffenirigLeg" - Fabricated from 0.034 in; thick coated st
Formed to slip over hanger wire. Length to vary.
ARMSTRONG WORLD INDUSTRIES INC-"STL-J
2. Hanger Assembly-Located at each main runner~cross tee, inlE
tion. Consisting of a hanger eyelet or other appropnate connector
hanger wire and a Class~ed "?tiff Leg". (Item No. 10): Len~ to
with max length to be 30 Ill. Dlam of WlIe to be 0.105 Ill. nun.
3. Gypsum Board" - Supplied in sheets, 48 in. Wide, by, mi? 8 ft .10
and min 5/8 in. thick. Wallboard fastened to cross tees Wlth Phill
bugle headed steel screws 1 in. long spaced 6 in. on c~ter.
4. Supports - Any structural steel or' wood members SIZed and Spi
as required to support hang~r assembly (Item 2). .
Refer to General Information~ Roof Deck Constructions, (Roofing ~
als and Systems Directory) for items not evaluated.
"Bearing the UL Classification Mark
Construction No. 293A
Uplift - Class 15
Fire Not Investigated
1. Framing System - The framing system identified as "7301 Lay-
Framing System" used to support the soffit, consists of the f?llow:
Classified Components: . c
IA. Main Runners* - Nominal 12 ft long, spaced 48 Ill. OC . _
ported by hanger assemblies (Item 2) at a spacing of 2 ft OC
ARMSTRONG WORLD INDUSTRIES INC -"7301"
1B. Cross Tees* - Nominal 4 ft long, installed perpendiclliar t<
main runners and spaced 2 it OC (ML-6148).
LOOK FOR 1