Loading...
HomeMy WebLinkAboutBuilding Maintenance (final notice) 4/25/2001 e OSHKOSA ON THE WATER INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN CORRECTION NOTICE r~ ,~ ~ ~ ~ t.f ( -V~[ ~ '- & ~ f~...Urr.~ r I,\LI\~U I i I: 'Compliance ~o Issue Date 12/11/2000 Compliance Date 04/30/2001 IMMEDIATELY Address 1012 HARNEY AVE Iflspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS Name Address 1230 MONROE ST City OSHKOSH State Zip Code WI 54901 -0000 Sent to TERRY B/MARJEAN E GABLE ~ Owner U Contractor ~ Other U Inspector ~ Required for Occupancy Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction ~LL VIOLATIONS NOTED BELOW SHOULD NOW BE CORRECTED. CONTINUED OCCUPANCY OF THIS DWELLING UNIT WITHOUT MAKING CORRECTIONS VIOLATES BOTH STATE AND LOCAL ORDINANCES WHICH CAN RESULT IN FINES. PLEASE CONTACT THIS OFFICE PRIOR TO APRIL 30, 2001 TO ARRANGE FOR A FINAL INSPECTION TO ASSURE COMPLIANCE. OCCUPANTS 1012 HARNEY AVE OSHKOSH WI 54901 - Item # 1 Code 16-35A (3) Compliance Yes Compliance Date 01/10/2001 IMMEDIATELY Description AN INSPECTION OF THE BASEMENT REVEALED IT HAS NOT BEEN PROPERLY CLEANED AND SANITIZED. WASTE PRODUCTS WERE NOTED ON THE FLOOR Item # 2 Code. 16-34A (3)a Compliance Yes Compliance Date 12/27/2000 IMMEDIATELY Description THERE IS LIVE OPEN WIRING IN THE BASEMENT SOUTH OF THE SERVICE. THERE ARE ALSO OPEN KNOCKOUTS ON THE FURNACE AND THE OUTLET BOX ON THE SERVICE IS LOOSE. TO BE CORRECTED BY A LICENSED CONTRACTORTHE DRYER IS NOT PROPERLY WIRED AND REQUIRES CORRECTION. Item # 3 Code 16-35A (4) Compliance No Compliance Date 02/12/2001 IMMEDIATELY Description THE FURNACE VENTING IS UNSUPPORTED AND SHALL BE REPAIRED. Item # 4 Code 16,..35A (4) Compliance No Compliance Date 02/12/2001 IMMEDIATELY Description THE DRYER IS VENTING INTO THE BASEMENT WITH PLASTIC VENT PIPE. THE DRYER SHALL BE VENTED TO THE OUTSIDE WITH METAL (FOIL) PIPE. THIS INTERIOR VENTING IS CREATING A FIRE HAZARD ABOVE THE DRYER (COBWEBS, ETC) Item # 5 Code 16-35A (3) Compliance No Compliance Date 02/12/2001 IMMEDIATELY Description THERE IS NO RELIEF VALVE RUNOFF TUBE ON THE WATERHEATER A RUNOFF TUBE IS REQUIRED.THE WATER HEATER GAS SUPPLY IS OF FLEXIBLE TUBING WHICH IS PROHIBITED. THE ABANDONED 1/4" REFRIGERATOR WATER LINE SHALL BE REMOVED. Page 1 of 3 e OSHKOSH ON THE WATER INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN CORRECTION NOTICE Issue Date 12/11/2000 Compliance Date 04/30/2001 IMMEDIATELY Address 1012 HARNEY AVE Compliance No Inspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS Sent to Address 1230 MONROE ST City OSHKOSH State Zip Code WI 54901 -0000 Name ~ Owner I TERRY B/MARJEAN E GABLE U Contractor I ~ Other I OCCUPANTS U Inspector I ~ Required for Occupancy I Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction ALL VIOLATIONS NOTED BELOW SHOULD NOW BE CORRECTED. CONTINUED OCCUPANCY OF THIS DWELLING UNIT WITHOUT MAKING CORRECTIONS VIOLATES BOTH STATE AND LOCAL ORDINANCES VVHICH CAN RESULT IN FINES. PLEASE CONTACT THIS OFFICE PRIOR TO APRIL 30,2001 TO ARRANGE FOR A FINAL INSPECTION TO ASSURE COMPLIANCE. 1012 HARNEY AVE OSHKOSH WI 54901 - Item # 6 Code 16-33A (7) Compliance Yes Compliance Date 12/18/2000 IMMEDIATELY Description THERE WAS NO SMOKE DETECTOR INSTALLED IN THE BASEMENT. A SMOKE DETECTOR SHALL BE INSTALLED IMMEDIATELY. Item # 7 Code 16-35A (1)a Compliance No Compliance Date 07/31/2001 IMMEDIATELY Description THERE ARE NUMEROUS HOLES IN THE INTERIOR BASEMENT WALLS. COLD AIR AND WATER CAN ENTER THE BASEMENT THROUGH THEM, THE WALLS TO BE SEALED. Item # 8 Code 16-33A (6) Compliance No Compliance Date 07/31/2001 IMMEDIATELY Description THE BASEMENT STEPS/LADDER HAVE NOT BEEN FRAMED PROPERLY AND SHALL BE REPAIRED PER REQUIREMENTS OF BUILDING INSPECTOR THIS VIOLATION WAS NOTED IN ORDERS ISSUED ON THIS DWELLING APRIL 2, 1993. Item # 9 Code 16-33A (9)a Compliance No Compliance Date 07/31/2001 IMMEDIATELY Description ALL LIVING UNIT ENTRYWAYS SHALL BE EQUIPPED WITH SOLID CORE DOORS AND DEADBOL T LOCKS DEFINED IN SECTION 16-22 OMC). BOTH EXTERIOR ENTRY DOORS ARE DAMAGED AND SHALL BE REPLACED. THIS VIOLATION WAS ORDERED CORRECTED ON THIS DWELLING APRIL 2,1993. Item # 10 Code 16,..33A (6) & 21.04 Compliance No Compliance Date 07/31/2001 IMMEDIATELY Description THE FRONT ENTRY STEPS HAVE BEEN INSTALLED WITHOUT REGARD FOR BUILDING CODES. THE RISER HEIGHTS ARE NOT UNIFORM AND THERE ARE NO HANDRAILS ON EITHER SIDE. THE STEPS SHALL BE REPAIRED/REPLACED TO CODE.THIS VIOLATION WAS NOTED IN ORDERS ISSUED ON THIS DWELLING APRIL 2, 1993. Page 2 of 3 e OSHKOSH ON THE WATER .. INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVFLOPMENT CITY OF OSHKOSH, WISCONSIN CORRECTION NOTICE Address Issue Date 12/11/2000 Compliance Date 04/30/2001 IMMEDIATELY 1012 HARNEY AVE Inspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS City State Zip Code OSHKOSH WI 54901 -0000 Name ~ Owner I TERRY B/MARJEAN E GABLE U Contractor I ~ Other I OCCUPANTS U Inspector I ~ Required for Occupancy I Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction ALL VIOLATIONS NOTED BELOW SHOULD NOW BE CORRECTED. CONTINUED OCCUPANCY OF THIS DWELLING UNIT WITHOUT MAKING CORRECTIONS VIOLATES BOTH STATE AND LOCAL ORDINANCES VVHICH CAN RESULT IN FINES. PLEASE CONTACT THIS OFFICE PRIOR TO APRIL 30, 2001 TO ARRANGE FOR A FINAL INSPECTION TO ASSURE COMPLIANCE. Sent to Item # Description Item # Description Item # Description Summary Compliance No Address 1230 MONROE ST 1012 HARNEY AVE OSHKOSH WI 54901 - 11 Code 16-36A (3) Compliance Yes Compliance Date 01/10/2001 IMMEDIATELY THE SECOND FLOOR (ATTIC) IS IN USE AS A SLEEPING ROOM. HABITABLE ROOMS REQUIRE AT LEAST 50% OF CEILING HEIGHTS BE 7 FEET. THIS VIOLATION WAS NOTED ON THIS DWELLING IN ORDERS ISSUED APRIL 2,1993. 12 Code 16-35A (6) Compliance Not Checked Compliance Date 01110/2001 IMMEDIATELY NO OWNER OF RENTAL PROPERTY IN THE CITY SHALL RENT OR ALLOW OCCUPANCY OF ANY DWELLING UNIT UNLESS IT SAFE AND CLEAN AND COMPLlE;S WITH THE OSHKOSH MINIMUM HOUSING ODE. @@@@DISCLOSURE OF ANY CONDITION WHICH CONSTITUTES A HAZARD TO TENANT SAFETY R CREATES A RISK OF PERSONAL INJURY, WHETHER OR NOT THE OWNER KNOWS OR COULD KNOW N A BASIS OF REASONABLE INSPECTION IS REQUIRED BEFORE RENTAL. 13 Code 16-37A (3) Compliance Yes Compliance Date 12/18/2000 IMMEDIATELY OWNERS SHALL NOTIFIY THE TENANTS AND INSURE THAT GARBAGE SHALL BE PROPERLY STORED BEHIND AND ADJACENT TO THE REAR OF THE DWELLING FARTHEST FROM ANY PUBLIC STREET OR WALK. GARBAGE TO BE PUT OUT FOR PICKUP NO EARLIER THAN 4:00PM THE DAY BEFORE PICKUP.GARBAGE AND DEBRIS UNDER FRONT PORCH TO BE REMOVED AND STORED TO THE REAR IT IS THE PROPERTY OWNERS RESPONSIBILITY TO CONFIRM COMPLIANCE WITH THESE ORDERS PRIOR TO THE DUE DATES (236-5137) TO AVOID CITATIONS AND COURT ACTION. FAILURE TO K::;ONFIRM CORRECTIONS WILL BE CONSIDERED NON-COMPLIANCE AND RESULT IN POSSIBLE IMMEDIATE CITATATIONS. SHOULD THIS LIVING UNIT BECOME VACANT IT SHALL NOT BE RE-RENTED OR OCCUPIED UNTIL SUCH TIME ALL VIOLATIONS HAVE BEEN CORRECTED. Signature DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL (920) 236-5050 FOR INSPECTION. Date Page 3 of 3