HomeMy WebLinkAboutBuilding Maintenance (final notice) 1/5/2001 CORRECTION NOTICE bl/o-~/6 f f'~~ i l f'OTIGE '~""_~' l;.-,fj ~,~ 1~ll.~ . O' OSHKOSH ON THE WATER INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN Issue Date 12/11/2000 Compliance Date 01/15/2001 IMMEDIATELY Address 1012 HARNEY AVE Compliance No ~ Owner U Contractor ~ Other U Inspector ~ Required for Occupancy Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction IF YOU DO NOT CONTACT THIS OFFICE BY JANUARY 15, 2001 WITH A SCHEDULE OF CORRECTIONS lAND THEIR DUE DATES, CITATIONS WILL BE ISSUED.PREVIOUS ORDERS ISSUED TO OWNER ON APRIL ~, 1993. THE DWELLING BECAAME VACANT AND WAS PUR~HASED AND OWNER OCCUPIED. NOW ~HAT IT IS AGAIN RENTAL ALL CURRENT AND PRIOR ORDERS SHALL BE MET. Name TERRY B/MARJEAN E GABLE Address 1230 MONROE ST Inspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS City State Zip Code OSHKOSH WI 54901 -0000 Sent to OCCUPANTS 1012 HARNEY AVE OSHKOSH WI 54901 - Item # 1 Code 16-35A (3) Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description AN INSPECTION OF THE BASEMENT REVEALED IT HAS NOT BEEN PROPERLY CLEANED AND SANITIZED. WASTE PRODUCTS WERE NOTED ON THE FLOOR. Item # 2 Code 16-34A (3)a Compliance No Compliance Date 12/27/2000 IMMEDIATELY Description THERE IS LIVE OPEN WIRING IN THE BASEMENT SOUTH OF THE SERVICE. THERE ARE ALSO OPEN KNOCKOUTS ON THE FURNACE AND THE OUTLET BOX ON THE SERVICE IS LOOSE. TO BE CORRECTED BY A LICENSED CONTRACTOR.THE DRYER IS NOT PROPERLY WIRED AND REQUIRES CORRECTION. ' Item # 3 Code 16-35A (4) Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description [THE FURNACE VENTING IS UNSUPPORTED AND SHALL BE ~EPAIRED. Item # 4 Code 16-35A (4) Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description [THE DRYER IS VENTING INTO THE BASEMENT WITH PLASTIC VENT PIPE. THE DRYER SHALL BE rvENTED TO THE OUTSIDE WITH METAL (FOIL) PIPE. THIS INTERIOR VENTING IS CREATING A FIRE HAZARD ABOVE THE DRYER (COBWEBS, ETC) Item # 5 Code 16-35A (3) Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description [THERE IS NO RELIEF VALVE RUNOFF TUBE ON THE WATERHEATER. A RUNOFF TUBE IS REQUIRED.THE WATER HEATER GAS SUPPLY IS OF FLEXIBLE TUBING WHICH IS PROHIBITED. THE IABANDONED 1/4" REFRIGERATOR WATER LINE SHALL BE REMOVED. Page 1 of3 0' OSHKOSH ON THE WATER INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN CORRECTION NOTICE Issue Date 12/11/2000 Compliance Date 01/15/2001 IMMEDIATELY Address 1012 HARNEY AVE Compliance No Sent to Address 1230 MONROE ST Inspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS City State Zip Code OSHKOSH WI 54901 -0000 Name ~ Owner I TERRY B/MARJEAN E GABLE U Contractor I ~ Other I OCCUPANTS U Inspector I ~ Required for Occupancy I Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction IF YOU DO NOT CONTACT THIS OFFICE BY JANUARY 15, 2001 WITHA SCHEDULE OF CORRECTIONS lAND THEIR DUE DATES, CITATIONS WILL BE ISSUED.PREVIOUS ORDERS ISSUED TO OWNER ON APRIL ~, 1993. THE DWELLING BECAAME VACANT AND WAS PURC,HASED AND OWNER OCCUPIED. NOW ~HAT IT IS AGAIN RENTAL ALL CURRENT AND PRIOR ORDE~S SHALL BE MET. 1012 HARNEY AVE OSHKOSH WI 54901 - Item # 6 Code 16-33A (7) Compliance No ComplianceOate 12/18/2000 IMMEDIATELY Description THERE WAS NO SMOKE DETECTOR INSTALLED IN THE BASl=MENT. A SMOKE DETECTOR SHALL BE INSTALLED IMMEDIATELY. Item # 7 Code 16-35A (1)a Compliance No Compliance Date 01/10/2001 IMMEOIA TEL Y Description THERE ARE NUMEROUS HOLES IN THE INTERIOR BASEMENT WALLS. COLD AIR AND WATER CAN ENTER THE BASEMENT THROUGH THEM, THE WALLS TO BE SEALED. Item # 8 Code 16-33A (6) Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description [THE BASEMENT STEPS/LADDER HAVE NOT BEEN FRAMED J;>ROPERL Y AND SHALL BE REPAIRED PER REQUIREMENTS OF BUILDING INSPECTOR. THIS VIOLATION WAS NOTED IN ORDERS ISSUED ON THIS DWELLING APRIL 2,1993. Item # 9 Code 16-33A (9)a Compliance No Compliance Date 01/10/2001 IMMEDIATELY Description !ALL LIVING UNIT ENTRYWAYS SHALL BE EQUIPPED WITH SOLID CORE DOORS AND DEADBOL T LOCKS (DEFINED IN SECTION 16-22 OMC). BOTH EXTERIOR ENTRY DOORS ARE DAMAGED AND SHALL BE REPLACED. THIS VIOLATION WAS ORDERED CORRECTED ON THIS DWELLING APRIL 2,1993. Item # 10 Code 16-33A (6) & 21.04 Compliance No Compliance Date 01/1 0/2001 IMMEDIATELY Description HE FRONT ENTRY STEPS HAVE BEEN INSTALLED WITHOUT REGARD FOR BUILDING CODES. THE RISER HEIGHTS ARE NOT UNIFORM AND THERE ARE NO HANDRAILS ON EITHER SIDE. THE STEPS SHALL BE REPAIRED/REPLACED TO CODE.THIS VIOLATION :WAS NOTED IN ORDERS ISSUED ON THIS DWELLING APRIL 2,1993. Page 2 of 3 O. OSHKOSH ON THE WATER INSPECTION SERVICES DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT CITY OF OSHKOSH, WISCONSIN CORRECTION NOTICE Issue Date 12/11/2000 Compliance Date 01/15/2001 IMMEDIATELY Address 1012 HARNEY AVE Name ~ Owner I TERRY B/MARJEAN E GABLE U Contractor I ~ Other I OCCUPANTS U Inspector I ~ Required for Occupancy I Occupancy SINGLE FAMILY Notice 0 First . Final 0 Other I Introduction IF YOU DO NOT CONTACT THIS OFFICE BY JANUARY 15, 2001 WITH A SCHEDULE OF CORRECTIONS ND THEIR DUE DATES, CITATIONS WILL BE ISSUED.PREVIOUS ORDERS ISSUED TO OWNER ON APRIL ,1993. THE DWELLING BECAAME VACANT AND WAS PURCHASED AND OWNER OCCUPIED. NOW HAT IT IS AGAIN RENTAL ALL CURRENT AND PRIOR ORDERS SHALL BE MET. Sent to Item # Description Item # Description Item # Description Summary Compliance No Inspected By BRUCE LUEDTKE/BRIAN NOE INSPTRS City State Zip Code OSHKOSH WI 54901 -0000 Address 1230 MONROE ST 1012 HARNEY AVE OSHKOSH WI 54901 - 11 Code 16-36A (3) Compliance No Compliance Date 01/10/2001 IMMEDIATELY HE SECOND FLOOR (ATTIC) IS IN USE AS A SLEEPING ROOM. HABITABLE ROOMSREQUIRE AT LEAST 50% OF CEILING HEIGHTS BE 7 FEET. THIS VIOLATION WAS NOTED ON THIS DWELLING IN ORDERS ISSUED APRIL 2, 1993. 12 Code 16-35A (6) Compliance No Compliance Date 01/10/2001 IMMEDIATELY NO OWNER OF RENTAL PROPERTY IN THE CITY SHALL RENT OR ALLOW OCCUPANCY OF ANY DWELLING UNIT UNLESS IT SAFE AND CLEAN AND COMPLIES WITH THE OSHKOSH MINIMUM HOUSING CODE. @@@@DISCLOSURE OF ANY CONDITION WHICH CONSTITUTES A HAZARD TO TENANT SAFETY OR CREATES A RISK OF PERSONAL INJURY, WHETHER OR NOT THE OWNER KNOWS OR COULD KNOW ON A BASIS OF REASONABLE INSPECTION IS REQUIRED BEFORE RENTAL. 13 Code 16-37A (3) Compliance No Compliance Date 12/18/2000 IMMEDIATELY OWNERS SHALL NOTIFIY THE TENANTS AND INSURE THAT GARBAGE SHALL BE PROPERLY STORED BEHIND AND ADJACENT TO THE REAR OF THE DWELLING FARTHEST FROM ANY PUBLIC STREET OR ilVALK. GARBAGE TO BE PUT OUT FOR PICKUP NO EARLIER THAN 4:00PM THE DAY BEFORE PICKUP.GARBAGE AND DEBRIS UNDER FRONT PORCH TO BE REMOVED AND STORED TO THE REAR. IT IS THE PROPERTY OWNERS RESPONSIBILITY TO CONFIRM COMPLIANCE WITH THESE ORDERS PRIOR TO THE DUE DATES (236-5137) TO AVOID CITATIONS AND COURT ACTION. FAILURE TO CONFIRM CORRECTIONS WILL BE CONSIDERED NON-COMPLIANCE AND RESULT IN POSSIBLE IMMEDIATE CITATATIONS. SHOULD THIS LIVING UNIT BECOME VACANT IT SHALL NOT BE RE-RENTED OR OCCUPIED UNTIL SUCH TIME ALL VIOLATIONS HAVE BEEN CORRECTED. DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL (920) 236-5050 FOR INSPECTION. Signature Date Page 3 of 3