HomeMy WebLinkAboutBuilding Z7-2174-1007
~
~
OJHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
. www~ci.oshkosh.wi. us
ON THE WATER
October 30, 2007
David W Kussart
Quantic Architecture LLC
1047 N Layndalle Drive
Appleton, WI 54914
Doug Marsh
Fox Valley Technical College
P.O. Box 2227
Appleton, WI 54912-2277
Site: Plan Number: Z7-2174-1007
S.J. Spanbauer Center
3601 Oregon St
Oshkosh WI 54902
For:
Description: Welding Lab Addition and Alteration
Object Type: Building only
Class of Construction: lIB - 740 Sq Ft.; Unsprinklered
Occupancy: B: Business / Office
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Note: Additional review is required prior to the area above the welding booths being used for storage.
Key Item(s) I Conditions:
. IRC Section 603 Combustible Materials in Types I and II Construction. Section 1/302 has been
revised to show non-combustible construction per the attached drawing. Plywood roof sheathing shown
in section 2/302 is to be fire-retardant-treated in order to be installed on a type IIB building.
. IDC 2208.1 [Comm 62.2208] Welding. The details of design, workmanship and technique for welding,
inspection of welding, and qualification of welding operators shall conform to the requirements of the
specifications listed in Sections 2204, 2205, 2206 and 2207. Drawings do not show weld size or type,
verifY that welds meet requirements shown in structural calculations.
. Comm 5.34 No person may perform structural welding unless the person holds a registration issued by
Department of Commerce. Provide welders registration numbers for all people doing welding on this
project.
. Comm 61.30(3) I IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment.
j:\l1Jspections\Pian Revit'w\C\\lmnerdal Pi;m Rcv.i.ew 2007\l72174-1007 360 i Oreg()1J St BIdg Oniy.doc
Page 1 of2
. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department orits
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the design.er of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
rian oe
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
l:'\In$pDdil1n~\PLm Revlew\CommerL'laJ Plan Rev.iew 2001'271174-1007 360 I OregoTI St Bidg Only.dD<:
Page 2 of2
ALTERATIONS & ADDITION
S. J. SPANBAUER CENTER
FOX VALLEY TECHNICAL COLLEGE
OSHKOSH, WISCONSIN
NEJI'l CEMENT COMP051TION
"SOARD COVER OVER
11-1/:2'" X 1-5/e>" 5TEEL 'C'
CEILIN~ ..JOI5TS @ 1:2" ole
~
~
~
=
~
:r
lr
~
()
~
~RINDIN~
BOOTH
C@>
REVISIONDRAVVING #1
October26,2007
QUANTIC ARCHITECTURE.lLC
PRoJECT NO. 00709
NEJI'l 5/8" GYPSUM
BOARD ON BOTTOM
OF CEILlN~ ..J015T5
~
~R'NDIN~
l2QQIt!
<@)
REVISED CROSS SECTION
SCAL.E: 1/::2" = 11-0"
UANTIC
000 ARCHITECTCRE. LLC