HomeMy WebLinkAboutBuilding Z7-2174-1007 ~ ~ OJHKOJH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 . www~ci.oshkosh.wi. us ON THE WATER October 30, 2007 David W Kussart Quantic Architecture LLC 1047 N Layndalle Drive Appleton, WI 54914 Doug Marsh Fox Valley Technical College P.O. Box 2227 Appleton, WI 54912-2277 Site: Plan Number: Z7-2174-1007 S.J. Spanbauer Center 3601 Oregon St Oshkosh WI 54902 For: Description: Welding Lab Addition and Alteration Object Type: Building only Class of Construction: lIB - 740 Sq Ft.; Unsprinklered Occupancy: B: Business / Office The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Note: Additional review is required prior to the area above the welding booths being used for storage. Key Item(s) I Conditions: . IRC Section 603 Combustible Materials in Types I and II Construction. Section 1/302 has been revised to show non-combustible construction per the attached drawing. Plywood roof sheathing shown in section 2/302 is to be fire-retardant-treated in order to be installed on a type IIB building. . IDC 2208.1 [Comm 62.2208] Welding. The details of design, workmanship and technique for welding, inspection of welding, and qualification of welding operators shall conform to the requirements of the specifications listed in Sections 2204, 2205, 2206 and 2207. Drawings do not show weld size or type, verifY that welds meet requirements shown in structural calculations. . Comm 5.34 No person may perform structural welding unless the person holds a registration issued by Department of Commerce. Provide welders registration numbers for all people doing welding on this project. . Comm 61.30(3) I IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment. j:\l1Jspections\Pian Revit'w\C\\lmnerdal Pi;m Rcv.i.ew 2007\l72174-1007 360 i Oreg()1J St BIdg Oniy.doc Page 1 of2 . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department orits authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the design.er of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. rian oe Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 l:'\In$pDdil1n~\PLm Revlew\CommerL'laJ Plan Rev.iew 2001'271174-1007 360 I OregoTI St Bidg Only.dD<: Page 2 of2 ALTERATIONS & ADDITION S. J. SPANBAUER CENTER FOX VALLEY TECHNICAL COLLEGE OSHKOSH, WISCONSIN NEJI'l CEMENT COMP051TION "SOARD COVER OVER 11-1/:2'" X 1-5/e>" 5TEEL 'C' CEILIN~ ..JOI5TS @ 1:2" ole ~ ~ ~ = ~ :r lr ~ () ~ ~RINDIN~ BOOTH C@> REVISIONDRAVVING #1 October26,2007 QUANTIC ARCHITECTURE.lLC PRoJECT NO. 00709 NEJI'l 5/8" GYPSUM BOARD ON BOTTOM OF CEILlN~ ..J015T5 ~ ~R'NDIN~ l2QQIt! <@) REVISED CROSS SECTION SCAL.E: 1/::2" = 11-0" UANTIC 000 ARCHITECTCRE. LLC