Loading...
HomeMy WebLinkAboutBuilding Z8-2169-1007 'i-' ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER October 24, 2007 Kevin Salmon Michael J WilkusAIA 11487 Valley View Rd Eden Prairie MN 55344 Dunham Associates 50 So Smith St, Suite 180 Minneapolis, MN 55402 Joe Wight Bradley Operating Limited Partnership 11520 N port Washington Road Suite 202 Mequon, WI 53092 Phyllis Senn Papa Murphy's Pizza 5302 Wesrhal1Ave Louisville, KY 40214 Site: Plan Number: Z8-2169-1007 Papa Murphy's Pizza 220 W Murdock Ave Oshkosh WI 54901' For: Description: Tenant space alterations Object Type: Building only Class of Construction: lIB - 1240 Sq Ft.; Unsprinklered Occupancy: M: Mercantile / Retail Maximum No of Occupants: 22 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Hem(s) / Conditions: . IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. . IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6 inches up onto walls. Sheet A-I finish schedule indicates 4 inch base, please revise to 6 inches to comply with code. . COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. .COMM 2603.4.1.3 Walk-in coolers. In unsprinklered buildings, foam plastic having a thickness that does not exceed 4 inches (102 mm) and a maximum flame spread of75 is permitted in walk-in coolers or freezer units where the aggregate floor area does not exceed 400 square feet (37 m2) and the foam plastic is covered by a metal facing not less than 0.032-inch-thick (0.81 mm) aluminum or corrosion-resistant steel having a minimum base metal thickness of 0.016 inch (0.41 mm). A thickness of up to 10 inches (254 mm) is permitted where protected by a thermal barrier. Verify compliance with these requirements as details on cooler specifications were not provided with plan submittal, this information shall be provided to field inspector. Flnspediuns\Plan Revit'w\('omme,'Cia! .Hm Reyiew 2007'Z3-2169-! OUt 220 VlMurdock A \'t' BkJg Only.doc Page 1 of2 -+- ~ ,~ . . Comm 61.30(3) /IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHVAC equipment. Be aware that mc 1004.3.2.4 contains additional restriction for air movement in corridors . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. . MUN 30 This review does not include review for signage. Applications for and questions regaurding signage permits should be directed to Todd Muehrer - Associate Planner (920) 236-5062. . MUN 15 NOTE: Contact Anne Boyce - Health Services (920) 236-5029 for additional information as to Health code requirements. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to he obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. ~~ ~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 "! :'lnsp;;cliuns\Pkm Revit'w\Commerdal PI,llJ R",yjt~W 20\J7\18-2169-1 on: 2?,OW Murdock Avo: BJdg Only.doc Page 2 of2