October 24, 2007
Kevin Salmon
Michael J WilkusAIA
11487 Valley View Rd
Eden Prairie MN 55344
Dunham Associates
50 So Smith St, Suite 180
Minneapolis, MN 55402
Joe Wight
Bradley Operating Limited Partnership
11520 N port Washington Road Suite 202
Mequon, WI 53092
Phyllis Senn
Papa Murphy's Pizza
5302 Wesrhal1Ave
Louisville, KY 40214
Site: Plan Number: Z8-2169-1007
Papa Murphy's Pizza
220 W Murdock Ave
Oshkosh WI 54901'
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: lIB - 1240 Sq Ft.; Unsprinklered
Occupancy: M: Mercantile / Retail
Maximum No of Occupants: 22
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Hem(s) / Conditions:
. IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
. IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls. Sheet A-I finish schedule indicates 4 inch base, please revise to 6 inches to comply
with code.
. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
.COMM 2603.4.1.3 Walk-in coolers. In unsprinklered buildings, foam plastic having a thickness that
does not exceed 4 inches (102 mm) and a maximum flame spread of75 is permitted in walk-in coolers or
freezer units where the aggregate floor area does not exceed 400 square feet (37 m2) and the foam plastic
is covered by a metal facing not less than 0.032-inch-thick (0.81 mm) aluminum or corrosion-resistant steel
having a minimum base metal thickness of 0.016 inch (0.41 mm). A thickness of up to 10 inches (254 mm)
is permitted where protected by a thermal barrier. Verify compliance with these requirements as details
on cooler specifications were not provided with plan submittal, this information shall be provided to
field inspector.
Flnspediuns\Plan Revit'w\('omme,'Cia! .Hm Reyiew 2007'Z3-2169-! OUt 220 VlMurdock A \'t' BkJg Only.doc
Page 1 of2
-+-
~
,~
. . Comm 61.30(3) /IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHVAC
equipment. Be aware that mc 1004.3.2.4 contains additional restriction for air movement in corridors
. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
. MUN 30 This review does not include review for signage. Applications for and questions regaurding
signage permits should be directed to Todd Muehrer - Associate Planner (920) 236-5062.
. MUN 15 NOTE: Contact Anne Boyce - Health Services (920) 236-5029 for additional information as to
Health code requirements.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
he obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~~
~
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00