HomeMy WebLinkAbout2007-Bldg/HVAC Z5-2138-0907
~
OJHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue .
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
ON THE WATER
October 9, 2007
Rod Burnett
Cubellis
281 Summer Street
Boston MA 02210
Don Penn
Don Penn Consulting Engineer
635 Westport Pkwy Ste 300
Grapevine TX 76051
Daye Spring
Horizon Group
5000 Hakes Srive
Muskegon, MI49441
David Farrington
Cubellis
2075 Silas Deane Hwy
Rocky Hill CT 06067
Site: Plan Number: Z5-2138-0907
Harry & David
3001 S Washburn St Space E30
Oshkosh WI 54904
For:
Description: Tenant space alterations
Object Type: Building and HV AC
Class of Construction: DB - 2984 Sq Ft.; . sprinklered
Occupancy: M: Mercantile I Retail
Maximum No of Occupants: 71
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Note: These plans are approved based on additional information submitted via email which included revisions to
sheets A.2, Ml.l, M2.l,Pl.1.
Key Item(s) I Conditions:
. IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with
this code and the international fire code. Construction of new walls may require the addition and or
relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns offire
sprinklers, the interior of the cooler and freezer are required to be sprinklered as welL
. IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
through The Retail Display area are required to have adequate emergency lighting to meet the performance
requirements oflBC 1003.2.11.3. Depending on configuration of store displays and racking additional
emergency illumination may be required to comply with these requirements.
. mc 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls. Finish schedule on sheet A.5 indicates 4 inch high coved - please revise to
required 6 inches.
. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
T:\lllsrecfjull~\Plan Review\CllmmerL'ial Hall Review :IOO 7\Z5-2138-0907 3001 S Wa:::hbum Sl Space E30 Illdg ilnd n\' AC.eto,
Page 1 of2
!
;
1
.
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
.. authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
SUBMIT:
· IECC 503.3.3.7 [Comm 63.0503(2)(1)J Balancing and documentation of the HV AC system shall conform
to the we. Balancing report required to be submitted prior to final occupancy being allowed.
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to connnencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 10 1.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below orthe address on this letterhead.
B anoe
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
590.00
590.00
0.00
l:\IJl$pedions\Phm Review\C'l1lJJmen:ia! Plan Review :007\Z5-21?8-0907 3001 S Washburn St Space .E30 DJdg and HVAC.doc
. Page 2 of2