HomeMy WebLinkAbout2007-Electric
G
OSHKOSH
ON THE WATER
Job Address 1424 S MAIN ST
CITY OF OSHKOSH
No
ELECTRIC PERMIT - APPLICATION AND RECORD
126884
Create Date 09/13/2007
Owner DONALD B CONDON ETAL ESTATE
Contractor BELL ELECTRIC LLC
Category 642 - Commercial-New Building Wiring
Plan
o Underground
Service
. New
120/208
Type . Overhead
126
Luminaires
o ~/A
o Change 0 Temp
Circuits
Volts
Amps 800
Switches 15
Receptacles
J
121
80
~~u_u .....
1-
::'''o~~'IU'' of rOMM ''''''''0"' fo, .ew 00","'''00 ,to..n''''wm.t
-.-----~-_.._---------_._-------_._-- -------..--:-- --I
I
__J
--I
I
J
Appliances
"debt acct
Fees: Valuation $85,750.00
Issued By: ~
Plan Approval
$0.00
$471.00
Date 09/20/2007
Perin it Fee Paid
D Permit Voided I
Parcelld # 0304810000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature Date
Agent/Owner
Address
1303 MIDWAY RD
MENASHA
WI 54952 - 1129
Telephone Number (920) 886-6589
.
To schedule inspections please cal1 the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
Stephenson. Ann M.
Sent:
To:
Subject:
Wednesday, September 12,20073:19 PM
inspections@ci.oshkosh.wi.us
Data posted to form 1 of
http://www.ci.oshkosh.wi.us/Com m unitLDevelopment/l nspections/Perm it_App _ Electrical_
2002.htm
*******
************************************************************************
"':5~' aD
Permit Fee Account:
DATE:
Job Address:
Owner:
Contractor:
Use Category:
Service:
Type:
Volts:
Receptacles:
Circuits:
Phase:
Amps:
Switches:
Fixtures:
Range:
Dishwasher:
Garbage_Disposal:
Dryer:
Water Heater:
Fan or blower:
Furnace:
A/C:
Electric Sign:
Motors:
Gas Pumps:
Other_Application:
Work Value:
Master Electrician:
Bl:
Description_of_work:
New Convenance Store
Yes ----
09-12-07
1424 S. Main
Condon Oil
Bell Electric
Commercial
New
Overhead
120/208
80
126
3 Phase
800
15
121
St.
85750.00
Richard Felten
Submit
~ J/1fD~
1
Electric Permit Work Card
Permit Number 126884
Create Date 9/13/2007
Job Address 1424 S MAIN ST
Owner DONALD B CONDON ETAL ESTATE Contractor BELL ELECTRIC LLC
Service ie New 0 Change 0 Temp 0 N/A I Type e Overhead 0 Underground 0 N/A
Volts 120/208 Circuits 126 Luminaires 121
Amps 800 Switches 15 Receptacles 80
UselNature 1642 - Commercial-New Building Wiring COMM 1 Alterations for new convenience store/laundromat. <<debt acct
of Work !
I
Value
$85,750.00
Inspections:
Date 10/30/2007
Type Rough In
Inspector Kevin Benner
approved
DatelTime requested: 10129/2007 07:59 AM
Access:
Requested by: BELL ELECTRIC LLC
o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid
Notice Type:
Ready DatelTime: 10/29/2007 07:59 AM
Phone Number: 378-6141 Tony
- -- - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - -- - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --
Date 10/30/2007 Type Service Inspector Kevin Benner not approved
Could not inspect the CT cabinet, grounding electroded conductor is too small, supplemantal was terminated at the CT cabinet, UG
inspection was not requested or conducted. 200A Service for the attached building: needs 10 for disc., confirm the bolt sizedfor the bonding
lug on building steel, confirm address, confirm 3-hr seperation from the attached building, bonding of the offset nipple, need additional
permit for second service? Reviewed with Tony.
DatelTime requested: 10/29/2007 07:59 AM
Access:
Requested by: BELL ELECTRIC LLC
o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid
Notice Type:
Ready DatelTime: 10/291200707:59 AM
Phone Number: 378-6141 Tony
------------------------------------------------------------------------------------------------------------------------------------------------------------
Date 11/02/2007
Type Consultation
Inspector Adam Krause
Discussed service installation - grouping of disconnects, GEC,
DatelTime requested: 11/02/2007 10:51 AM
Access:
Requested by: BELL ELECTRIC LLC
o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid
Notice Type:
Ready DatelTime: 11/0212007 10:51 AM
Phone Number:
-------------------------------------------------------------------------------------------------- - -
approved w/cond.
east to the west sides of the building.
Date 11/16/2007 Type Re Service Inspector Kevin Benner
he Gas is to be bonded & the building steel is to have a bonding jumper installed for
pproved to energize. Faxed to WPS 11/16/7
Date/Time requested: 11/15/2007 12:50 PM
Access:
Notice Type:
Ready Date/Time: 11/16/2007 00:00 AM
------------------------------------------------------------------------------------------------------------------------------------------------------------
Requested by: BELL ELECTRIC LLC
o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid
Phone Number: 378-6141 Tony