HomeMy WebLinkAboutHVAC Z2-2043-0907-H
~
OJHKOfH
I
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box lBO'
Oshkosh WI 54903-1130'
www.ci.oshkosh.wi.us
ON THE WATER
September 19,2007
Douglas L Geyer
HV AC Design Solutions
W7094 Spencer Road
Appleton WI 54914
Mark Showers
619 W 19th Ave
Oshkosh, WI 54902
Site: Plan Number: Z2-2043-0807-B
Real Marketing
601 W 6th Ave
Oshkosh WI 54902
For:
Description: New HV AC system
Object Type: BV AC only
Class of Construction: VB - 3948 Sq Ft.; Unsprinklered
Occupancy: B: Business I Office
Maximum No of Occupants: 15
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
· IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet
from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys,
parking lots and loading docks. Caution - air intake can not be located as shown on plan, relocate to
comply with code. -- Per discussion with designer the intake will be located on the South end of the
building.
· MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened
from view per zoning department requirements. Contact Todd Muehrer - Associate planner (920) 236-
5057 for additional information on screening requirements. No BV AC permit will be issued until
location and screening information is provided and approved. Per discussion with designer the Ale
Condenser will be placed on the South end of Building, which is to be enclosed by a fence along
property lines per the approved plan on file with the planning department
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Corom 61.31(1). .
\\OSHKOSHM!SFS\Dcpalimcnts\!nspix:tinn;i\Plan Rcvicw\(:tHmncrcial Phm Rc:,'jcw 2007'Z2.20-l3.0~07-H flU! W 6th Avc' !-lv/\e (lnly,doc
Page I of2
SUBMIT:
· Comm 6L50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office. .
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shaiI relieve the designer of the responsibility for designing a safe building, structure, or compOnent.
Inquiries concerning this correspondence may be made to me at the number listed below or the address. on this letterhead.
~
~
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
Page 2 of2