Loading...
HomeMy WebLinkAbout0126623-Plumbing o OSHKOSH ON THE WATER Job Address 2830 ATLAS AVE CITY OF OSHKOSH No 126623 PLUMBING PERMIT - APPLICATION AND RECORD iCOMM / New 21,000 sf distribution facility for Fastenal. "DEBiT ACCf**~ I Contractor GARTMAN MECHANICAL SERVICES Bathtub Shower Water Softner Whirlpool Floor Drain 1 Local Waste Lavatory 2 Lndry Tray 1 Clothes Wshr - Toilet 2 Disposal Bidet - Res. Sink 1 Dishwasher Beer Tap Bar Sink Sump Pump Lab Sink Water Heater Classrm Sink Sterilizer Site Drain Breakrm Sink Dip Well Roof Drain EjectorlGrind Drink Ftn Misc. Hose bib Fixtures UselNature of Work Owner Create Date 09/06/2007 -- Category 440 - Industrial-Interior Plan Wait. St. Shamp Sink Coffee Maker Ice Chest FlrlWst Sink Int Grease Trap Exam Sink Catch Basin Ext Grease Trap Sculry Sink Wash Ftn RPZ Valve Hand Sink Urinal Eye Wash Statn Plaster Sink Standp Rec Wtr Sewer Mtrs Surgeons Sink Ice Maker Deduct Meters F Prep Sink Gar Drain Wtr Usage Mtrs Serv Sink Soda Disp ------------...-.~1 I I Size Material Type # Conn. Type Sanitary Sewer Storm Sewer Water Service Parcelld # Valuation__.-!!?,609..:.00 Plan Approval ___~_~9.9Q Permit Fees ____~_E9:00 0 Perm~\I~!~~clJ Issued By (/)/Y7{",;O Date 09/06/2007 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address 520 W SOUTH PARK AV Agent/Owner OSHKOSH WI 54902 - 6470 Telephone Number 920-231-5530 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (Le. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ~EP-06-200'.. O~.:.: 4, ,~~""" City of Oahkosh Jnspooticm Services Division POBox 1130 OIhkosh, WI 54903-1130 PhoDe: (920) 236-5050 Pax; (9ZQ) 236-5"084 , 11 J ~ eLL I U II S ~ r V lee s P,01101 No. ~fjl ~. I ~ ~d~) 0I~OJ8 ON f"i WhTn Plumbing Permit Application I hereby apply for a pennit to do and install the following pl~mbing OD d1e premirlCS bcrc:inaftcr degcn'bed, the woO< to conform (0 thll Wiscons:!n State Plumbing Code, in the pC'tformanc~ of which all p~ haeto agree to and Brll bound by 8aid Stll1utes. · Application(s) and fee(s) can be brol.tght to City Hall, Room 205 or mailed to TnspectionServices. PO Box 1128, Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees b=ing doubled or $\ 00,00 plus tho normal permit fee, which ever is grea.ter. OR ig: ~~~: 1~~:~:.<~~r;t~~:l~':.:;:' t::,:~r JCCO"1 S",,'" ..d havogd'qwa(. (u,d,. chICh ow Job Addreis#{t3IJ AJ{t.t..r All,; Va)lle(IneludinlllllbcnndTTlltcriBI~) Jlt6~() Date fj-:-k- D] Owner lJ.,vJ LI;'~ 1""..".., '~"'c,-~cpntracior ~~O---/'\ .;1,3/- 5530 DSingle Family []Duplex OMulti-Family []Rental !Sa'Commercial []Indllstrial u,ttry Tnr Lab Sink Plqtr;:r Sink SUlrilil:Cl' Mill':. FbttuIU _ Electric C..t....ctor ~ ~ q I OR. DEl'ctric Installatl.. Verillcati.. torm attache. d .. U; -S~"'Th PuU . Use I Nature of Work ~ Y c. ?:~ J--:!,}.3t Number ofFlS(tu.res: BllthlUt:l WbiTlpool uvalm'y Toilct Rai.lltn\( ~ 1- -L.~ BIR" $ln1o: Wallll' Hf;Ilwr -L o Gas ~eot!:l PwrVnl Sho~ Floor Drain -L_ ......L DiIlllOQ:ll Diahwll~her Sump Pump Ej~lor/Orind W~!crr SuilnClT l.QI..'1lIWlllll~ Clolhc5 W~l1r Bidel 9m:r Till' ClQl;~nn Sink CDleh BllIIin Wllihfim UrinAl Oar Dntin SoUu DiSJl COt{dll MIlMr Comm. (<Ill MAl/ill" llile OrRin IWL>E Drain -'-- OrlnlcFcn Walt. St- IllO {:tl~t axlm Sink 5~ulry Sink Hand SIn"\( f' Prep SInk s~ Sink Ir1t G~ 1i~p ISIn GNasc Trap R-P.;?;. Valve ShOll1p SinK fllrlWst Sink Slandll Rec Eye WaAA Sin Surpam; Sink 9nlllknn Sink Wit :ilCWl:r MITll D~dllCl Mc:rrr.; DipWClll Hane Bibs -+- Wrr USBBC Mil's S~tary Sewer Type # Conn. Type Stann Sewer Water Service Size Ma.teriaJ 1.1/05 OCT-15-200703:10 PM P,02/02 t,. . '", . 1 . ,......: \ o' "e.. 0 :.,~:f"" \'~\;ji;J;.:,_;;,.;~...~.:\F'~ PIf'~'I( -#- I;l. b 6 fl. J WATER C.-LCUl.J\TlON WORKSHEeT FORf.M~ttf(_~..M-\.'!z'~- - INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE 1, Demand or building in gallon$ per minute. WSFU's _L~- := (GPML.JJ~ - . 2. Differe~ in .'.viilllon from main or external pressure tank to building centrol valve. (feet) 3. Size 01 the walerm.ter. (When applic,ble) 5180 _. 314-i-. 1. __,1.112- __,2. __,3" ...0-.4'" ":",6._ 4. Developed length from main or .:lCtemal pru$ure lank to building control valve. (feet) --~- 5. Low pressure at main in street or extemllll pressure lank. (PSig)S ~ CALCULATE WATER SERVICE PRESSURE LOSS ~5 6. Low pres sur. at main in street or e.temal pressure lank. (value or I 5 above) " WaJ-.<,A 6ev<Ar.< ullll r (dWe oK- c..~e [;CIIl(M Wattr a.Nice ~ioameler Is ___' Malerial is ;.-r.-------. Pressure loss per 100't ,. __Ibl. X ____(decimalequivalent 0' $erviclt length, i.e.: 65ft :: .65) --- '1. (Sublract line 7. from line 6.) subtotal 8. Oelermine Pressurlllllil'n or 10" duelo IIlevilltion. (multiply the villulI of:' 2 abave by .434) value o( ~S. ___ 9. Av.llable pressure eftllr Ule bldg. contral valve. (Subtract or add line 8. Enter in "S".) subtotal - CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF .tAN) r;( B. Available pressure after the blelg. contrcf valve. (from "g. above) Value (lr .S" c. Pressurl!llos, of water meter (when meter is required Dr it\stalled) Value or '"e" -z.... ~3 O. PrtlSSUnI at controlling fixtur.. (Controlling blur. is (Subtract line C. rrom line B.) .ubtotal Value 0(.0. J..f- ) 3 (Subtrilct the value 0' D.) subtotal - ~ - E. Olffl!lf'8Ilce in .Ievaden between the building control valve - and tn. controlling flxtur. In reet _-=- X .434 psllfL Value of .E" -- (Sul:ltrad the value af E->'., subtotal _ J J _ F. PrnSUr8 lasa due to \V.1l.,r ,,,.lment devices, instantaneous wa.r heate", and beekflow preventer. which I&IV. lh., cantlUlling fixture. Value of "F" _22- -- (Pressure loss due to _ -----:- 0 _) "2 o (Sublfact the value or F.) subtotal ~.......L.2- o. Developed length (rom building control valve to controlling fixture in teet ll> X 1.5 Value of .GO _ t S- o . . . ",. (Divide by the value or G.) lubtotal --~ (Wilter distribution piping material Is _____--) Multiply by 100_ --~( A.. Pressure available for uniform lots UA" = 110 - '.",....... JIItl I