HomeMy WebLinkAbout2007-Letter-Ahern Co (Fire Protection System Installation) ~\ J. F. AHERN CO. MECHANICAL & FIRE PROTECTION CONTRACTORS 201 Morris Court, P.O. Box 1316 Fond du Lac, WI 54936-1316 (920) 921-9020 P · (920) 921-8666 f www.jfahern.com September 4, 2007 Building Inspector -- Brian Noe City of Oshkosh 215 Church Avenue -- PO Box 1130 Oshkosh, WI 54901 T -920/236-5051 F-920/236-1130 RE: FIRE PROTECTION SYSTEM INSTALLATION WYLDEWOOD CONDOS - BUILDING 9 376 WYLDEWOOD OSHKOSH, WISCONSIN 54901 AHERN FIRE PROTECTION PROJECT No. 995644 Dear Brian: Enclosed is a copy of the Contractor's Material and Test Certificates covering the above-referenced Fire Protection System Installation for your files. Very truly yours, AHERN FIRE PROTECTION A division ofJ. F. Ahem Co. ~fl}.$~ Mark L. Jozefowski, Superintendent MLJ/ksj Enclosure LCITY09-04-2007.DOC RECEIVED SEP 5 2007 DEPARTMENT OF COMMUNITY DEVELOPMENT INSPECTION SERVICES DIVISION Building the Midwest Since 1880 An Equal Opportunity Employer AHERN FIRE PROTECTION Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME Wyldewood Condominiums AFP W.O. #: 995644 I DATE: June 13,2007 PROPERTY ADDRESS 376 Wyldewood Oshkosh, WI 54901 ACCEPTED BY APPROVING AUTHORITIES (NAMES) 1. City of Oshkosh (Building Inspector -- Brian Noe) 2. Oshkosh Fire Department (Battalion Chief - Stu Schrottky) 3. 4. ADDRESS Plans 1. 215 Church Avenue -- Oshkosh, WI 54901 2. 101 Court Street -- Oshkosh, WI 54901 3. 4. INSTALLATION CONFORMS TO ACCEPTED PLANS ~YES DNO EQUIPMENT USED IS APPROVED ~ES DNO IF NO, EXPLAIN DEVIATIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION l8'YES DNO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? INSTRUCTIONS IF NO, EXPLAIN HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: Item No.'s 2 & 3 will 1. SYSTEM COMPONENTS INSTRUCTION ~r DNO be forwarded by AFP 2. CARE AND MAINTENANCE INSTRUCTIONS YES DNO at closeout time. 3. NFPA 25 ES DNO LOCATION OF SUPPLIES BUILDINGS SYSTEM Building #9 MAKE MODEL YEAR OF K- QUANTITY TEMPERATURE MANUFACTURE FACTOR RATING CentralLF II TY2234 Res. Pendent White 2007 4.9 59 155 Deq. SPRINKLERS PIPE AND TYPE OF PIPE Liahtwal/ Non-Threadable. Thinwall Threadable. Black FITTINGS TYPE OF FITTINGS Grooved. Threaded. Mechanical Tees FLOW ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION TYPE MAKE MODEL MIN. SEC. Water Flow Detector System Sensor WFD t7 N/A EXPLAIN ANY ALARM PROBLEMS: ALARM DEVICES LOW AIR ALARM DEVICE ALARM OPERATED U'eE MAKE I MODEL PRESSURE PROPERLY lN/A\ . D It:' '" C'1~1e r , YES I NO .........." II ""~ ~i 'fI ~. ~ I EXPLAIN ANY ALARM PROBLEMS: SEP 5 2007 DEPARTMENT OF , .....,... If- AI"" .... ,..... -- I .41'......-;... _J~_ ,,11.0.. !NSPECTION SERVICES DIVISION CENTRAL MONITORING SIGNALS RECEIVED ALARM SERVICE LOCA TION(S) TYPE OR PRESSURE NAME OF REMOTE WATERFLOW SWITCH LOW-AIR OTHER SERVICE DETECTOR FLOW SUPERVISORY SUPERVISING LOCATION(S): ~~ STATION (ON-SITE) REMOTE REMOTE NAME OF SERVICE: MONITORING ALARM SERVICE SIGNALING (OFF-SITE) PHONE: OTHER: LOCA TION(S): EXPLAIN ANY ALARM SIGNALING PROBLEMS: DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. N~ TIME WATER ALARM TIME TO TRIP WATER TRIP POINT AIR THROUGH TEST PRESSURE AIR PRESSURE PRESSURE REACHED TEST OPERATED CONNECTION',2 OUTLET ',2 PROPERLY DRY PIPE MIN. SEC. PSI PSI PSI MIN. SEC. YES NO OPERATING WITHOUT TEST Q.O.D. WITH Q.O.D. IF NO, EXPLAIN: . OPERATION: o PNEUMATIC 0 ELECTRIC o HYDRAULIC ~~ PIPING SUPERVISED DYES DNO DETECTING MEDIA SUPERVISED DYES DNO DOES VALVE OPERATE FROM THE MANUAL TRIP, REMOTE, OR BOTH CONTROL STATIONS DYES DNO IS THERE AN ACCESSIBLE FACILITY IN EACH IF NO, EXPLAIN DELUGE & CIRCUIT FOR TESTING PREACTION DYES DNO VALVES DOES EACH CIRCUIT DOES EACH CIRCUIT MAXIMUM TIME TO OPERATE SUPERVISION MAKE MODEL LOSS ALARM OPERATE VALVE RELEASE OPERATE RELEASE YES NO YES NO MIN. SEC. ~ LOCATION & MAKE & MODEL SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE PRES E FLOOR (FLOWING) . INLET OUTLET INLET OUTLET FLOW REDUCING (PSI) (PSI) (PSI) (PSI) (GPM) VALVE TEST . Ahern Fire Protection 1 MEASURED FROM TIME INSPECTORS TEST CONNECTION IS OPENED. 2 NFPA 13 ONLY REQUIRES THE SO-SECOND LIMITATION IN SPECIFIC SECTIONS. 2 TEST DESCRIPTION TESTS BLANK TESTING GASKETS WELDING CUTOUTS (DISCS) HYDRAULIC DATA NAMEPLATE REMARKS SIGNATURES Ahern Fire Protection HYDROSTATIC' ydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in exces psi (10.2 'bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. PNEUMATIC: Establish 40-psi (2.7 bars) air pressure and measure drop, which Shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT PSI (_Bar) for -k HRS. IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED J ,v"\ YES D NO EQUIPMENT OPERATES PROPERLY fV!"I DYES D NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OR SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED eO,.R TESTING SYSTEMS OR STOPPING LEAKS? QrYES D NO DRAIN READING OF GAUGE LOCATE2tEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST TEST SUPPLY TEST CONNECTION: PSI ( Bar) CONNECTION OPEN WIDE: ~ PSI LBar) UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISER OTHER EXPLAIN FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. VERIFIED BY COpy OF THE CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR UNDERGROUND PIPING. ~YES D NO FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING ~ES D NO IF POWDER-DRIVEN FASTENERS ARE USED IN CONCRETE, HAS IF NO, EXPLAIN REPRES1lNTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED? W~ D~Doo NUMBER USED LOCATIONS NUMBER REMOVED o WELDED PIPING IF YES... NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS B2.1? DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS DYES QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS B2.1? DYES DNO DNO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO ENSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? DYES DNO DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? NAME PLAlEPROVIDED -I8:T YES D NO ES D NO IF NO, EXPLAIN DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: NAME OF SPRINKLER CONTRACTOR AHERN FIRE PROTECTION, 201 MORRIS COURT .- FOND DU LAC, WI 54935 TESTS WITNESSED BY G JURISDICTION (SIGNED). TITLJQ J..-- ~ ;A1- FOR PROPERTY OWNER (SIGNED) TITLE "2 -'7 TTLE 1~mtf ill DATE ~:) --7 3 ~sconSin Assembly Location I ~5 Assembly Type ~E o DC Detector se, ~~O~ / Initial Test 1 '1:;t check Closed tight Leaked j L / Static j 7 Final Test ';",0 Closed tight , Static PSID 2'nd'check Closed tight Leaked , StaH2- I, , -------------- PSID - - - - - - - - - - -. - - - - - PSID o Closed tight 2'nd check Static PSID DETECTOR BYPASS ASSEMBLY INITIAL TEST ),1'st check 2'nd check ,; 0 Closed tight 0 Closed tight o Leaked 0 Leaked Static PSlD Static - - - - - - - - ~.>;,,,,.,; DETECTOR BYPASS ASSEMBLY FINAL TEST o Closed tight 0 Closed tight Static PSID Stalie" PSID ----------------------- PSID SEP 5 2007 DEPARTfvlENT OF COMMUNITY DEVELOPMENT ASSEMBLIES IN FIRE PROTECTION SYSTEMS Forward Flow Test -:) J./, Designed flow rate v I <; , Note: Include hose stream demand where applicable - - - - - - ~ - -- - - - GPM Actual flow rate GPM IndiCating Control Valves o No. one control valve open Partes) Replaced/Comments ------------------------------ o Locked I HEREBY CERTIFY THE TEST RESULTS ARE TRUE AND THE TEST WAS CONDUCTED BY ME PERSONALLY. Tester Name (PD, nt) ~~ ~ IY1@RegistartionNoJ]J"l'Z.5.TimeofDay Tester Signature >~ Phone No. ~ 'I) J'r Date 0/ Jc}/tJ :; SBD-10754 . 12/02 Distributed to the following: Owner and tester, rptBlank_ WIDoubleCheck_DC_Detector