HomeMy WebLinkAbout13093-Electrical maintenance
~
e
OSHKOSH
ON THE WATER
Issue Date 9/5/2007
Address 638 W 18TH AVE
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 10/5/2007
Compliance No
Sent to
~ Owner
Name
I JEFFREY R LAWRENCE
Address
638 W 18TH AVE
City
OSHKOSH
State Zip Code
WI 54902 - 0000
Introduction
While performing a final inspection at the request of the new owner, the following violations were found.
U Required for Occupancy
Occupancy
Item # Code NEC 300.16(A) Compliance No Compliance Date 10/05/2007
Description A box or terminal fitting having a separately bushed hole for each conductor shall be used wherever a change is made to NM cable. A cable
urrently terminates in the kitchen cabinet. It should be in an enclosure.
09/05/2007
Last
Updated
Item # 2 Code NEC 300 Compliance No Compliance Date 10/05/2007
Description V\n octagon box in the basement by the electrical panel has an open knockout and no cover installed.
09/05/2007
Last
Updated
Item # 3 Code Comm 23.02 Compliance No Compliance Date 10/05/2007
Description ~ny room with a shower, toilet, or tub shall contain mechanical ventilation which shall terminate outside the building; 50 cfm intermittent or 30
~fm continuous.
09/05/2007
Last
Updated
13093
Page 1 of 2
G
OSHKOSH
ON THE WATER
Issue Date 9/5/2007
Address 638 W 18TH AVE
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 10/5/2007
Compliance No
Sent to
~ Owner
Name
I JEFFREY R LAWRENCE
Address
638 W 18TH AVE
City
OSHKOSH
State Zip Code
WI 54902 - 0000
U Required for Occupancy
Occupancy
Item # 4 Code Mun. Code 11-44 Compliance No Compliance Date 10/05/2007
Description Service entrance cable shows signs of damage on horizontal run along driveway. 'Damage is minor enough, applying silicone caulk should be
enough to stop water/moisture from entering the cable.
09/05/2007
Last
Updated
Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns
or questions at 236-5274.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of ' 10/5/2007
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature of wha~.~eds to be ~SP5~'d.
,.// !~
Signature t/-~. // . W/"'J-<-
Date~ ;-07
Inspected by: Adam Krause 236-5274 akrause@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Company
Signature
Date
Also Sent to: U Bldg
U Elec
U HVAC
U Plbg
U Designer
U Other
U Inspector
SECKAR ELECTRIC
13093
Page 2 of 2