Loading...
HomeMy WebLinkAboutBuilding Z4-2074-0807 .~ OJHKOJH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER August 30, 2007 Richard Fisher Fisher & Associates, LLC 642 Tholsen Dr Kimberly WI 54136 Browne LLC 2605 Jackson St Oshkosh, WI 54901 Site: Plan Number: ZA-2074-0807 Primo Italian Steak House 2605 Jackson Street Oshkosh WI 54901 For: Description: Tenant space alterations Object Type: Building only Class of Construction: VB - 620 Sq Ft.; Unsprinklered Occupancy: A: Assembly Maxinrum No of Occupants: 288 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements NOTE: This plan approval is based on revised toilet room layout faxed on 8/29/07 Key Item(s) / Conditions: . ANSI 604.3.1 Clearance around the water closet shall be 60 inches minimum measured perpendicular from the side wall, and 56 inches minimum from the rear wall. No other fixtures or obstructions shall be within the water closet space.. Revised plans faxed on 8/29/07 indicate the required clearance will be met --Verify required clearance is being provided and all remaining accessibility requirements are met. . IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire.extinguisher is 75 feet. . IBC 2603.4 Thermal barrier. Except as provided for in Sections 2603.4.1 and 2603.7, foam plastic shall be separated from the interior of a building by an approved thermal barrier of 0.5-inch (12.7 mm) gypsum wallboard or equivalent thermal barrier material that will limit the average temperature rise of the unexposed surface to not more than 2500F (120oC) after 15 minutes of fire exposure, complying with the standard time-temperature curve of ASTM E 119. The thermal barrier shall be installed in such a manner that it will remain in place for 15 minutes based on FM 4880, UL 1040 or UL 1715. Combustible concealed spaces shall comply with Section 716. Per discussion with designer roof will be constructed as per permit # 126346 with YJ.-inch dens deck - not as shown in cross section in plans. f:\Inspcdions\Plan Review\('ommen:ial prom Review 2()()7\l4-2074-0807 2605 Jacbon StBldg Only.doG Page lof2 . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement fonn SBD-9720 with this office A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Brian oe Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 J:'-In,;p,,,j;uns\Plan I~I;;VleW\COlllmen:;al Plan Rev)!;I;.' 2007\74-2074-0807 2605 Jacbon St Bldg OnJydoc Page 2 of 2 :::-- --- --- - -- - -.._- ::: ... ..;... ..... .;,;,.'" ;L" ...... _ ..... _ _ - - 642 Thelosen Drive Kimberly, WI 54136 Phone: 920-687-9035 Fax: 920-78B-2965 . . - Fisher & Ass()ciates, LLC . . ", , . . . Fax To: BRIAN NOE From: Richard Fisher fax: (920) 236-5084 Date: August 29, 2007 Phone: Pages: 2 Re: PRIMO ITALIAN STEAK HOUSE Scott Shimmers -Albright construction ee: o Urgent o For Review o Please Comment 0 Please Reply 0 Please Recycle -Comments: This is a revised men's toilet room layout at 1/8" =1'.0" e3'-1" , , , : , ! : .: I i I , I : , I : : , I ! : I I : ! I , ~ , , , I , I I I I : I I I I : , i : I i , , , 11'.3" ~ i i!~ ~;n ~ ~ ~ffl ~ I ~ I ~E .t-~O .-1 ~ "'-iji (\'. I(\~- oQ .-1 ~ 2~ "(\ "tI G; ~E c ~~~ ~~ ~ IEXITI ~ ~ - ij hir ~ EXISTING 0 ~ ~ ~~J ~S ::j ::Ihi &> 2 ~ .~ 0 In ,:~ ~ f' Z !!l ~~ "-':l" II! I ~ I~~ ~~~ ~~g ~~ ~I ~gi <~\J> F8~ II! Q8~ I Ff g~C ~~i .., cr ~ = ~ g ~ ~ 0 0 ~ m ~ ~ I Ii' !q~ ::-tiji , -; : . , !him plJE 16'_6"