August 21, 2007
Coutland Morgan
Coutlan Morgan Architect
711 Fielder Rd
Arlington, TX 76012
Scott Fisher
Prime Retail
217 E Redwood St 20th Floor
Baltimore MD 21202
Site: Plan Number: Z2-2054-0807
DEB
3001 S Washburn S1. Space D210-D230
Oshkosh WI 54904
For:
Description: Tenant space alterations
Object Type: Building & BV AC
Class of Construction: DB - 9000 Sq Ft.; Sprinklered
Occupancy: M: Mercantile I Retail
Maximum No of Occupants: 264
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
· IBC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems
are required to be provided at the time of inspection.
· IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with
this code and the international fire code. Construction of new walls may require the addition and or
relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire
sprinklers
· IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
· IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
are required to have adequate emergency lighting to meet the performance requirements ofIBC
1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance
with the code in effect at the time of construction. Any altered path of egress, or new path of egress,
and any new emergency lighting being installed is required to comply with current code requirements.
The relocated exterior doors require emergency light on the exterior side of doors.
\\OSHKOSHM1SFS'j)epartmur(s',rnSrKdinns\Plan Rcyicw\Oim!11ereial Pian Review Z()(l7\Z2-2054-0~()7 3UOi S Washburn St Bidg & I IV:\Cdoe
Page 1 of3
· IMC 602.2.1 Materials exposed within plenums. Except as required by Sections 602.2.1.1 through
602.2.1.4, materials exposed within plenums shall be noncombustible or shall have a flame spread index of
not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with
ASTM E 84. Caution on materials and equipment - i.e. speakers security equipment being located
above ceiling within the plenum space.
· IMC 606.2.1 Smoke detectors shall be installed in return air systern:s with a design capacity greater than
2000 cfin......
· IMC 606.4.1 The duct smoke detectors shall be connected to a fire alarm system. The actuation of a
smoke detector shall activate a visible and audible supervisory signal at a constantly attended location.
· IMC 606.4.1 Exception 2. In occupancies not required to be equipped with a fire alarm system, actuation
of a smoke detector shall activate a visible and an audible signal in an approved location. Smoke detector
trouble conditions shall activate a visible or audible signal in an approved location and shall be identifies
as air duct detector trouble.
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
· MUN 30 This review does not include review for signage. Applications for and questions regarding
signage permits should be directed to Todd Muehrer- Associate Planner (920) 236-5057
SUBMIT:
· IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
through The Retail Display area are required to have adequate emergency lighting to meet the performance
requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with
these requirements prior to installation of emergency lighting system.
· Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. Please submit lighting work sheets.
· Comm61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
\\( )SH K()SH M ISFS\JkpartmcntS.,InstX'di"ns\Plan RGI'iew\Comm.:rcial Plan Rev!cw 2007\Z2-2054-0,,07 3<)()! S Washburn ST Bldg & HV:\C.doc
Page 2 of3
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
nan oe
Building Systems Consultant
(920) 236-5051 Monday- Friday 7;30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file