HomeMy WebLinkAbout13064-Electrical maintenance (GFCI)
e
OSHKOSH
ON THE WATER
Issue Date 8/22/2007
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 9/21/2007
Compliance No
Address
437 W 9TH AVE
Sent to
~ Owner
Name
I CAROL J THULL
Address
437 W 9TH AVE
City
OSHKOSH
State Zip Code
WI 54902 -6466
Introduction
U Required for Occupancy Occupancy
During the final inspection, the following violations were noted.
Item # 1 Code NEC 210.8 Compliance No Compliance Date 09/21/2007
Description Basement recepts. to be GFCI protected. Device in basement center by jack posts. Flourescent bath fixture contains unprotected modular
recept.
08/22/2007
Last
Updated
Item # 2
Description
Code NEC 406.3(B) Compliance No Compliance Date 09/21/2007
Receptacles and cord connectors that have grounding contacts shall have those contacts effectively grounded. Equipment ground for hall
recept. is not connected. Should terminate in octagon box above ductwork. Sump pump is 3 - wire fed from 2 prong recept.with 2 -3 prong
3dapter and no equipment ground.
08/22/2007
Last
Updated
13064
Page 1 of 2
G
OSHKOSH
ON THE WATER
Issue Date 8/22/2007
INSPECTION SERVI<::ES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 9/21/2007
Compliance No
Address
437 W 9TH AVE
Name
CAROL J THULL
Address
437 W 9TH AVE
City
OSHKOSH
State Zip Code
WI 54902 -6466
Sent to
l!J Owner
Introduction
U Required for Occupancy Occupancy
During the final inspection, the following violations were noted.
Item # 3 Code NEC 11 0.14(B) Compliance Not Checked Compliance Date 09/21/2007
Description Splices Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal
or alloy. Check splices in open octagon box above ductwork.
08/22/2007
Last
Updated
Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns
or questions at 236-5274.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 9/21/2007
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
. natureOfWhatn.~.,,;~
Signature .' ~ ~~____ Date 0' .<2. -17
,;...
""'-'"
Inspected by: Adam Krause 236::S274 akrause@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Company
Signature
Date
Also Sent to: U Bldg
U Elec
U HVAC
U Plbg
U Designer
U Other
U Inspector
QUALITY ELECTRIC
13064
Page 2 of2