HomeMy WebLinkAbout0126319-Electric e OSHKOSH ON THE WATER Job Address 2737 HARRISON ST CITY OF OSHKOSH No 126319 ELECTRIC PERMIT - APPLICATION AND RECORD Owner OSHKOSH TRUCK CORP , Create Date 08/15/2007 Contractor NORTHLAND ELECTRICAL SERVICES L Category 643 - Commercial-Addition/Remodels Plan Service b New o Change 0 Temp . N/A Type 0 Overhead o Underground Volts Circuits Luminaires Amps Switches Receptacles Appliances Use/Nature of Factory/Interior alterations - remodel first floor office area under existing mezzanine and office build out of existing unfinished Work mezzanine level. Issued By: $100,000.00 ~ Plan Approval $0.00 Permit Fee Paid $513.00 Fees: Valuation Date 08/17/2007 o Permit Voided I Parcelld # 1519600000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 1100 ORVILLE DR NEW LONDON WI 54961 - 9418 Telephone Number 920-531-1197 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ftt'5( 3 - City of Oshkosh Division of Inspection Services P.O. Box 1130 Oshkosh, WI 54903-1130 Phone (920) 236-5050 Fax (920) 236-5084 (f) OfHKOfH ON THE WATER ELECTRICAL PERMIT APPLICATION . All information after bold categories must be provided. Incomplete applications will not be processed. . Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees being doubledor $100.00 plus the normal permit fee, which ever is greater. OR I ou are a contractor artici atin in the Permit Fee Account S stem and have ade check here if vou want this processed through vour account 0 DATE 8-13-2007 JOB ADDRESS 2737 Harrison street OWNER Oshkosh Truck Corporation CONTRACTOR Northland Electrical Services CHECK lii ALL APPLICABLE USE CATEGORY OSingle Family ODuplex DMulti- Family DRental GlCommercial Dlndustrial SERVICE ONew OChange OTemporary &INot Applicable TYPE OOverhead OUnderground 1XIN0t Applicable FILL IN THE APPROPRIATE BLANK WITH THE NUMBER I Receptacles # . Circuits # Volts Phase Amps Switches # Fixtures # CHECK &i ALL APPLICABLE ORange OFan OR Blower o Motors ODishwasher OFurnace DGas Pumps OGarbage Disposal OAlC DOther ODryer OWater Heater OElectric Sign ,,:;\0... 9..,\t DESCRIPTION OF ALL WORK BEING DONE office s ace includin Wiring of 8,000 sq. ft. additional Ii htin and rece tacles. MASTER ELECTRICIAN Tom Co] lrlr SUBMITTED BY~1~ce REGEWEC AUG 1 7 2007 DEPARTMENT OF COMMUNITY DEVELOPMENT ?s- \ yo?r- INSPECTION SERVICES DIVISION Manager, Northland Electrical VALUE (Including labor and aU materials including light fixtures) $ 1 n n , non _ 00 --_ Electric Permit Work Card JQL+-Address 2737 HARRISON ST Permit Number 126319 Create Date 8/15/2007 Owner OSHKOSH TRUCK CORP Contractor NORTHLAND ELECTRICAL SERVICES L Service New Q Change Q Temp ~ N/A~ Type Q Overhead Q Underground ~ N/A Volts Circuits Luminaires Amps Switches Receptacles Value $100,000.00 Use/Nature of Work i43 -Commercial-Addition/Remodels Factory/ Interior alterations -remodel first floor office areaunder existing nezzanine and office build out of existing unfinished mezzanine level. Inspections: Date 10/16/2007 Type Rough In_ Inspector Kevin Benner approved w/cond. 2EQUEST LINE /WILL BE READY FOR AN INSPECTION TO THE UPSTAIRS MEZZANINE the offices have one receptacle in each one that there are 470 degrees of bends in the ENT that serves it. I reviewed what the correction :ould be with Chuck. Chuck called @ 10/16/7 @ 11:57AM & stated that the violations have been corrected. also reviewed the power listribution system, 8 I discussed that the plumbing pipes in the dedicated space for a control panel would have to be relocated. Date/Time requested: 10/15/2007 01:06 PM Notice Type: Ready Date/Time: 10/15/2007 01:06 PM Access: Electrician on site Chuck (920) 538-2432 Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid -------------------------------------------- -- ----- - - ------- ------------------------------------------------------------------------------------------ Date 11/01/2007 Type Roughln Inspector Kevin Benner approved tEQUEST LINE /READY FOR A ROUGH INSPECTION temainder of the second floor. "Please inspect 11/1 the electrician will be on site"` Date/Time requested: 10/31/2007 03:11 PM Notice Type: Ready Date(fime: 11/01/2007 00:00 Access: Electrician will be on site Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: (920) 538-2432 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid - - - - ------ -------------------------------------- Date 11/19/2007 Type Roughln Inspector Kevin Benner approved tEQUEST LINE /READY FOR A ROUGH INSPECTION OF THE 1ST FLOOR ONLY )iscussed the HVAC contractor installation of EMT connectors for chase nipples. Chuck agreed to discuss this with the contractor. Also liscussed the installation of suspended luminaires inthe offices. Date/Time requested: 11/16/2007 09:49 AM Notice Type: Ready Date/Time: 11/16/2007 09:49 AM Access• Requested by: NORTHLAND ELECTRICAL SERVICES LL Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid Date 11/29/2007 Type Rough In Inspector Kevin Benner approved tEQUEST LINE /WOULD LIKE A 1ST FLOOR MEZZANINE INSPECTION Date/Time requested: 11/28/2007 08:45 AM Notice Type: Ready Date/Time: 11/28/2007 08:45 AM Access: Phone Number: (920) 538-2432 Chuck Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: (920) 538-2432 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid Electric Permit Work Card .fob Address 2737 HARRISON ST Permit Number 126319 Create Date 8/15/2007 Owner OSHKOSH TRUCK CORP Contractor NORTHLAND ELECTRICAL SERVICES L Service New Q ChangeQ Temp ~ N/A Type Q Overhead Q Underground ~ N/A _J Volts Circuits Luminaires Amps Switches Receptacles Value $100,000.00 Use/Nature 3 -Commercial-Addition/Remodels Factory/ Interior alterations -remodel first floor office area under existing of Work ezzanine and office build out of existing unfinished mezzanine level. Inspections: Date 11!29/2007 Type Service Inspector Kevin Benner not approved ;EQUEST LINE /WOULD LIKE A SERVICE INSPECTION luilding steel bond to be a minimum of 1/0 CU :ales for the bus duct that the XFMR was fed from. DatelTime requested: 11/28/2007 08:45 AM Notice Type: Ready Date/Time: 11/28/2007 08:45 AM Access: Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: (920) 538-2432 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid ------------------------------------- -- - - -- -- --- ------------------ ------------------------------------------------------------------- - - ---- - - - - -- ----- Date 12/13/2007 Type Abv Ceiling Inspector Kevin Benner not approved nd Floor Only. \ Already started installing tiles /ENT in the Air-Plenum Ceiling, Removal of the old CL2 cables,CL2 cable support, MC upport (bathrooms & RTU). Reviewed with Chuck. Date/Time requested: 12/12!2007_ 02:48 PM Notice Type: Ready DatelTime: 12/12/2007 02:48 PM _ Access: Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: 538-2432 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid - ------------------------------------------------------------------------ -------------------- Date 12/13/2007 Type Abv Ceiling Inspector Kevin Benner approved w/cond. ____ 1st Floor North Side =Approved 2nd Floor Re-Inspect Partial =Need to do partial inspections through tiles throughout the installation. (North Conf .Rm no access above th ceiling) Date/Time requested: 12/13/2007__ 01:00 PM Notice Type: Ready Date/Time: 12/13/2007 01:00 P_M_ __ Access: Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: 538-2432 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid ------------------------------------- - ----- --- - - ------------------------------- --------------------------------------------------------------- - --- -- ---- - - -- Date 12/17/2007 Type Abv Ceiling Inspector Kevin Benner - _-..._ st Floor South side nd Floor Re-Inspect AC cable support (add ceiling wires), Unused raceway to be closed, box cover. teviewed with Chuck Date/Time requested: 12/17/2007 08:02 AM Notice Type: Ready Date/Time: 12/17/2007 08:02 AM Access• Requested by: NORTHLAND ELECTRICAL SERVICES LL Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid Phone Number: 538-2492 Chuck Electric Permit Work Card Job Address 2737 tiARRISON ST Permit Number 126319 Create Date 8/15/2007 Owner OSHKOSH TRUCK CORP Contractor NORTHLAND ELECTRICAL SERVICES L Service New Q Change Q Temp ~ N/A Type Q Overhead Q Underground ~ N!A J Volts Circuits Luminaires Value $100,000.00 Amps Switches Receptacles UseMature 3 -Commercial-Addition/Remodels Factory/ Interior alterations -remodel first floor office area under existing of Work ezzanine and office build out of existing unfinished mezzanine level. Inspections: Date 12/17/2007 Type Consultation Inspector Kevin Benner _ not approved 're-Final Inspection IFPA 72 requirements, Panet Schedules, Add-A -Depth rings, Again requested the talc's for the buss duct which feeds the area. Date/Time requested: 12/17/2007 00:00 PM Notice Type: Ready DatelTime: 12/17/2007 00:00 PM Access: Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: 538-2492 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid -------------------------------------------------------------------------------------------------- Date 12/18/2007 Type Abv Ceiling Inspector Kevin Benner te-Inspect _ ".- -- Aore MC support & raceway to be closed Date/Time requested: 12/17/2007 00:00 PM Notice Type: Ready DatelTime: 12/18/2007 00:00 AM Access: Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: 538-2492 Chuck Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid Date 12/21/2007 Type Final Inspector Adam Krause Notice Type: Ready Date/Time: 'artial Final Inspection -Awaiting talcs. of bus duct tap. -- - Date/Time requested: 12/18/2007 00:00 AM Notice Type: _ Ready Date/Time: 12/19!2007 00:0.0_AM Access:. Requested by: NORTHLAND ELECTRICAL SERVICES LL Phone Number: 538-2492 Chuc_ k Q Reinspect Fee Q Fee Wavied ^ Reinspect Fee Paid Date 09/23/2008 Type Note Inspector Allyn Dannhoff -wner & Electrical contractor failed to provide Electrical Calculations demonstrating the Buss Du rea is properly sized or the Buss Duct can support the additional electric demand. See attached 0/14/8 DatelTime requested: Access• Requested by: Q Reinspect Fee Q Fee Wavied approved w/cond. approved w/cond. ding electrical power to Muerman nEngineering. ^ Reinspect Fee Paid Phone Number: Benner, Kevin From: Fred Muermann [Fred@me-pe.com] Sent: Tuesday, October 14, 2008 12:43 PM To: Benner, Kevin Subject: RE: FW: Oshkosh truck MEZZANINE PROJECT Yes I do thank you Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042 Phone 920.894.7800 ext. 102 Fax 920.894.7916 -----Original Message----- From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Tuesday, October 14, 2008 12:41 PM To: Fred Muermann Subject: RE: FW: Oshkosh truck MEZZANINE PROJECT Hi Fred, I assume by this communication that you agree with this data. If so than this email is acceptable. Kevin Benner Electrical Inspector City of Oshkosh 920-236-5046 kbenner@ci.oshkosh.wi.us -----Original Message----- From: Fred Muermann [mailto:Fred@me-pe.com] Sent: Tuesday, October 14, 2008 10:42 AM To: Benner, Kevin Cc: Fred Muermann RMeyers@defense.oshkoshcorp.com; Corey Defferding Subject: RE: FW: Oshkosh truck MEZZANINE PROJECT Hello Kevin The Electrical contractor has completed the code required 30 day electrical metering, on the bus duct, feeder, through the summer during a time when there is maximum expected load -the maximum measured load during that time was 485 amps this is on the 1600 amp bus duct with a 1600 amp feeder. Do you need any further information on this? Or do you need this information furnished in another way to you Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042 1 Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Monday, April 14, 2008 9:15 AM To: Fred Muermann Subject: RE: Oshkosh truck MEZZANINE PROJECT The section that you reference would be Comm 16.23(2). If this would be the case I would expect that a typical July or August would be in order. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto:Fred@me-pe.com] Sent: Monday, April 14, 2008 8:50 AM To: Benner, Kevin Subject: RE: Oshkosh truck MEZZANINE PROJECT Yes I would agree- many changes over the years - What we could do is have it recorded for 30 days( in the summer) I believe that the NEC allows that as a method of load determination of existing systems that of course would be the added load with the existing load. Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Monday, April 14, 2008 8:43 AM To: Fred Muermann Subject: RE: Oshkosh truck MEZZANINE PROJECT I give up. I assume we do not know how to calculate the load. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 2 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto:Fred@me-pe.com] Sent: Monday, April 14, 2008 7:15 AM To: Benner, Kevin Subject: RE: Oshkosh truck MEZZANINE PROJECT Hello Kevin There is existing miscellaneous load that has a measured ampacity of 300 amps. This was measured prior to the office addition, the EC installed a recording amp meter and recorded for two weeks during the summer of 2007. Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Monday, April 14, 2008 7:10 AM To: Fred Muermann Subject: RE: Oshkosh truck MEZZANINE PROJECT Fred, Am I to assume that this panel board is the only item on this buss duct? Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Friday, April 11, 2008 2:22 PM To: Fred Muermann Subject: RE: Oshkosh truck MEZZANINE PROJECT It does not necessarily need to be a letter an email would be fine. The communication needs to include the actual equipment that is connected to this just as you would if you were to design this from scratch to determine your design and equipment. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto: Fred@me-pe.com) Sent: Friday, April 11, 2008 2:17 PM To: Benner, Kevin 3 Subject: RE: Oshkosh truck MEZZANINE PROJECT Opps sorry- I will do a letter Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us) Sent: Friday, April 11, 2008 12:24 PM To: Fred Muermann Subject: RE: Oshkosh truck MEZZANINE PROJECT No. Please reference the previous correspondence. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto:Fred@me-pe.com) Sent: Friday, April 11, 2008 11:24 AM To: Benner, Kevin Cc: Russ Eilers; Corey Defferding Subject: RE: Oshkosh truck MEZZANINE PROJECT Hello Kevin The office mezzanine electrical Load was connected to a 1600 amp bus duct that is fed from a 1200 amp breaker. Last summer( before the addition of the new load) the electrical contractor did a multiday load study and found that the highest was 300 amp, the added NEC calculated demand for the mezzanine office is 227 KVA or 274 amps. The contractor( Chuck at Northland Electric) measured the load again today and found the highest reading to be 360 amps, of course that would be without the AC operating and most likely with out the Elevator-- in any case the bus duct has adequate capacity for the added load Does this information suffice or do you need a letter from our office? Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 4 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Wednesday, April 09, 2008 12:16 PM To: Fred Muermann Subject: RE: Oshkosh truck project Hi Fred, Do not make this harder than it has to be! I just need know what the connected loads are on the buss duct and the total ampacity. You do not need to very specific just the general equipment and its load. This can be done with a document, we do not a line diagram. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto:Fred@me-pe.com] Sent: Wednesday, April 09, 2008 9:32 AM To: Benner, Kevin Cc: Corey Defferding; RMeyers@oshtruck.com Subject: RE: Oshkosh truck project Hello Kevin How shall the information be presented to you? do you need a revised one line diagram? do you need a revised overall floor plan showing where the bus duct is ? Is there a form or something that you need to show the load calculations Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Tuesday, April 08, 2008 7:51 AM To: Fred Muermann Subject: RE: Oshkosh truck project: Hi Fred, The project that you stated has been completed for a year was allowed to occupy 12/19/07. My calendar says that this is four months and in the four months from late December through early April I would not imagine that the air conditioning has been utilized in the worst case scenario with the elevator running and all other amenities that come with full occupancy. The first order for calculations was requested on 11/28/07. As the E.C. was allowed to not follow your engineered plans, I am certain that for future alterations this knowledge would or should be necessary. The occupancy of this project was allowed with the understanding that calculations would 5 be provided immediately. As always once someone gets what they want (occupancy) we do not get what we need to complete the project on our end, and then our customers complain that our office is being difficult. If your E.C. would have followed your engineered drawings I would not be questioning the installation. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 kbenner@ci.oshkosh.wi.us From: Fred Muermann [mailto:Fred@me-pe.com] Sent: Thursday, April 03, 2008 10:43 AM To: Benner, Kevin Cc: Kari Gehde; RMeyers@oshtruck.com Subject: RE: Oshkosh truck project Thank you Kevin Regarding the Bus Duct I will have to follow up with the owner, the contractor was to provide that- we initially had the load connected to another bus duct that had no load- the contractor elected to connect it to a different bus duct that was determined had load capacity . This office that is fed from the bus duct is up and operating for a year now, can I assume all that is required is a amperage reading on the duct feeder during occupied hours when the duct is loaded? Kind regards Fred Muermann President Muermann Engineering 116 Fremont St. Kiel, WI 53042. Phone 920.894.7800 ext. 102 Fax 920.894.7916 From: Benner, Kevin [mailto:kbenner@ci.oshkosh.wi.us] Sent: Thursday, April 03, 2008 9:56 AM. To: Fred Muermann Subject: RE: Oshkosh truck project Hi Fred, On another note I did require calculations for the bus duct in which we tapped a large load to serve the office installations that we did this past winter. Those offices are occupied and I have not received those calculations to date. Kevin Benner City of Oshkosh Electrical Inspector 920-236-5046 6 kbenner@ci.oshkosh.wi.us