Loading...
HomeMy WebLinkAboutBuilding Z2-2040-0707 ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue POBox 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER August 13, 2007 Chet Wesenberg 3162 Hayward Ave Oshkosh, WI 54904 Rob Abel 1402 W South Park Ave Oshkosh, WI 54902 Site: Plan Number: Z2-2040-0707 Quarry Condominiums 1406 South Park Ave Oshkosh WI 54902 For: Description: Alteration of existing unfinished basement space to finished living space Object Type: Building only Class of Construction: VB, 1510 sqFt. Occupancy: R2: Residential The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: · IDC 711.3 Any penetrations offrre rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems are required to be provided at the time of inspection. · IBC 907.2.10.1.2 Smoke alarms shall be installed and maintained in the following locations: · On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. · In each room used for sleeping purposes. · In each story within a dwelling unit, including basements. Plans submitted only show one detector - provide additional interconnected detectors to meetthe above requirements. · IBC 1009.1 Emergency Escape and Rescue Basements and sleeping rooms shall have at least one exterior emergency escape and rescue opening. The Library room is not to approved to be used as a sleeping room. Additionally if there is to be locking hardware installed on the Bedroom door, an additional emergency escape and rescue window is required to he provided to be accessible to the remaining portions of the hasement. · IBC 1009.4 Operational Constraints Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. F.In$pediuns\Plan Review\Curnmerc'iaJ P!;m Rt'view :>OD7\Z2-2040-0707 !."02 ';\1 SQUl], Park Ave Bldg Orliy.(kl(; Page 1 of2 · IBC 1009.5.1 Minimum Size The clear horizontal dimensions of the window well shall allow the emergency escape and rescue opening to be fully opened and provide a minimum accessible net clear opening of 9 sq ft with a minimum dimension of 36 inches. · IBC 1009.5.2 Window well Ladders or Steps Window wells with a vertical depth of more than44 inches shall be equipped with an approved permanently affixed ladder or steps. Ladders or rungs shallhave.ari inside width of at least 12 inches, shall project at least 3 inches from the wall and shall be spaced not more than 18 inches on center vertically for the full height of the window well. The ladder or steps shall not encroach into the required dimensions of the window well by more than 6 inches. The ladder or steps shall not be obstructed by the emergency escape and rescue opening. · IBC 1202.4.1.2 Natural Ventilation Where openings below grade provide required natural ventilation, the outside horizontal clear space measured perpendicular to the opening shall be one and one-half times the depth of the opening. The depth of the opening shall be measured from the average adjoining ground level to the bottom of the opening. · IBC 1207.2 Minimum Ceiling Heights Occupiable spaces, habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches. Bathrooms shall be permitted to have a ceiling height of 7 feet. · Comm 61.30(3) IIMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment. · Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). SUBMIT: · Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pertttits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. ~ ~~ Building Systems Consultant (920) 236-5051 bnoe@ci.oshkosh.wi.us Fee Required $ Fee Received $ Refund being processed $ 320.00 360.00 40.00 cc: Property file l:\Insp:::('il\Jns\Plan R(;_vi.t'\.v\Conrrnerl'iaJ .Plan Rev.lt:'w 2007\Z2h-2040-0707 1.+02 \"/ SouLh Park Ave r~Jdg Only.d~)<.: Page 2 of2