CITY OF OSHKOSH No 88337
PLUMBING PERMIT - APPLICATION AND RECORD
I
o
OSHKOSH
ON THE WATER
Job Address 2445 HICKORY LN
t
Owner MIKE ZESSIN Create Date 08/16/2001
Category 410 - Residential-I nterior Plan
Contractor O'NEILL ENTERPRISE INC
Bathtub 2 Shower Ejector/Grind
Whirlpool Floor Drain Water Softner
Lavatory 2 Lndry Tray Local Waste
-
Toilet 2 Lndry Stndp 1 Clothes Wshr
- -
Res. Sink 1 Disposal 1 Bidet
-
Bar Sink Dishwasher 1 Beer Tap
-
Water Heater Sump Pump 1 Dent. Oper.
Site Drain Classrm Sink Lab Sink
Roof Drain Breakrm Sink Sterilizer
Use/Nature
of Work
Dip Well
Drink Ftn
Wait. St.
Ice Chest
Exam Sink
Sculry Sink
Hand Sink
Plaster Sink
Surgeons Sink
F Prep Sink
Serv Sink
Shamp Sink
FlrlWst Sink
Catch Basin
Wash Ftn
Urinal
Standp Rec
Ice Maker
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
Size
Material
Type
#
Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation
$5,800.00
Plan Approval
$0.00
Permit Fees
Issued By
$78.00
Date 08/16/2001
U Permit VOided I
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Address 5575 CTY RD N
AgenUOwner
PICKETT
WI 54964 - 0000
---'- _ ---J.-
Telephone Number 428-4700 589-2007
"::'1'
~~\:'
Plumbing Permit Work Card
Permit Number 88337
~'..
JoorAddress 2445 HICKORY LN
Owner MIKE ZESSIN
,,/--"'egory 410- Residential-Interior
~dthtub I , t 2 Shower
Whirlpool Floor Drain
Lavatory I1G. Lndry Tray
Toilet U-'-~ Lndry Stndp
Res. Sink --L-1 Disposal
Bar Sink Dishwasher
Water Heater Sump Pump
Site Drain Classrm Sink
Contractor
Plan
O'NEILL ENTERPRISE INC
Ejector/Grind Dip Well F Prep Sink
~ Water Softner Drink Ftn Serv Sink
I Local Waste Wait. St. Shamp Sink
~ Clothes Wshr Ice Chest FlrlWst Sink
-------,--
(()1 Bidet Exam Sink Catch Basin
~ Beer Tap Sculry Sink Wash Ftn
-----JJ- Dent. Oper. Hand Sink Urinal
Lab Sink Plaster Sink Standp Rec
Sterilizer Surgeons Sink Ice Maker
Roof Drain
Use/Nature
of Work
Breakrm Sink
rEW SINGLE FAMILY INTERIOR-PLUMBING
- -----c~------~~l
Create Date 08/16/2001
Value
$5,800,00
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
Size Material Type # Conn.Type K \ t 1) ! '1-/ V I
Sanitary Sewer r$
j~
--
c ;;-/ '7 /
-~ F
() L--
Storm Sewer ("'
. " ~j
.
~
I .. '.
Water Service
.~ e~
~
~
Date 00/00/0000 Type Inspector U Approved I
61_1 b
stfft
~
~J
~
\ ~~ WL- fY1~ ~ R.~h
3-BG I-KS I-DW l-AW l-LT
WATER CALCULATION WORKSHEET FOR 2445 Hickory street 2-HB
NAME OF PROJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE;
3-BG I-KS I-DW l-AW l-LT
WATER CALCULATION WORKSHEET FOR 2445 Hi ckory Street 2-HB
NAME OF PROJECT
1\ 1.
"
,
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE
Demand of building in building in gallons per minute.
WSFU's 23. 5 = (GPM) 1 6 . 1
2.
Difference in elevation from main or external pressure tank to building control valve.
(feet) 6 3 I
3. Size of water meter (when meter is required) 5/8" _' 3/4"~, 1" ~. 1-112" _.2"_, larger size
4.
5.
Developed length from main or external pressure tank to' building control valve.
Low pressure at main in street or external pressure tank.
(feet) 1 0 '
(psi) 4 8
.. "
CALCULATE WATER SERVICE PRESSURE LOSS
6.
7.
Low pressure at main in street or external pressure tank. (valueof# 5 above)
Determine pressure loss due to friction in I" inch diameter
water service.
(Water service piping material is TYPE K Copper)
48
Subtract value of "7"
5.7
42.3
subtotal
8.
Determine pressure loss due to elevation,
(multiply the value of # 2 above by .434)
4.34
Subtract value of "8"
9.
Available pressure after the bldg.' control valve. (enter in "B" below)
subtotal
37.96
r CALCULATE THE I'RESSUBE AVAILAQ~F; F9R UN,.FORIVI,LOSS (VALUE OF nAIf)
l'
B. Available pressure after the bldg. control valve. (from "9" above)
Value of "B" 37.96
Subtract value of "C" 3
subtotal 34.96
Subtract value of "D" 20
subtotal 14.96
Subtract value of "E" 5.21
subtotal 9.75
C. Pressure loss of waterrru:~t~r (when meter is required)
D.
Pressure at controlling fixture.
(Controlling fixture is
)
PBV
E. Difference in elevation between the building control valve
and the controlling fixture in feet 12 X .434 psi/ft.
F.
G.
("
,
.,. A.
Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture. ~
(Pressure loss due to )
Subtract value of "F"
ra
9.75
subtotal
Developed length from building control valve to controlling
fixture in feet 60 X 1.5
90
. 11
Divide bYvalue of "G"
subtotal
(Water distribution piping rnaterialis
Coppe.r /PEX
)
Multiply by
100
Pre~sure available for uniform loss
nA" =
11
$80 -6479 CRt 1/98)
~-
WATER DISTRIBUTION DATASHEET
,Date: December 18, 2001
Name: O'NEILL ENTERPRISE
Project: NSFR
Street:
Street: 2445 HICKORY LN
City:
City:
1. 16.1 Gallon per minute buiding demand, predominatIy Flush Tank.
2. 54.0 Low pressure at the Main in the Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter.
4a.~ Lb loss from a 15.0 ft I" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop.
Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 6.6 ft per sec.
4b.~ Lb loss from a 63.0 ft 1" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150, inside diameter of .995 and a velocity of 6.6 ft per sec.
5. 3.9 Lb loss from a 3/4in Meter
6. 43.9 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
i'.
A = B-(C+D+E) x 100
F
A. ~ Pressure available for uniform loss (psill 00 feet of pipe).
B. ~ Lbs of pressure available at the Water Meter.
C. ~ Pressure needed at the controlling fixture. TIS FAUCET-MASTER BATHRM
D. ~ Lb loss resulting from a 12.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. 90.0 Ft Developed length from the 60.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tu~'fyPe M;, .ASTM B88
~-.."~..~
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
r,'
,! . ;
'",
0,
WATER DISTRIBUTION DATASHEET
Date: December 18, 2001
r
Name: O'NEILL ENTERPRISE
Project: NSFR
Street:
Street: 2445 HICKORY LN
City:
City:
1. 16.1 Gallon per minute buiding demand, predominatly Flush Tank.
2. 54.0 Low pressure at the Main in the Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter.
4a.~ Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop.
Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 6.6 ft per sec.
4b.~ Lb loss from a 63.0 ft 1" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150, inside diameter of .995 and a velocity of 6.6 ft per sec.
5. 3.9 Lb loss from a 3/4in Meter
6. 43.9 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
~,
f. :
A. -----1! Pressure available for uniform loss (psill 00 feet of pipe).
A = B-(C+D+E) x 100
F
B. ~ Lbs of pressure available at the Water Meter.
C. ~ Pressure needed at the controlling fixture. TIS FAUCET-MASTER BATHRM
D. ~ Lb loss resulting from a 12.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. 90.0 Ft Developed length from the 60.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Crosslinked Polyethylene (Pel.) Tubing ASTM F876
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4 6.5 9 15 22 31 53 0 0 0
Maximum FM WSFU 0 0 0 5 7 15 58 0 0 0
Maximum FT WSFU 4 8 11.5 21.5 35 58 142 0 0 0
1"-'.',,',
p . ,\
',-
Fixture Listing
rDate: December 18, 2001
Name: O'NEILL ENTERPRISE
Project: NSFR
Street:
Street: 2445 HICKORY LN
City:
City:
Non Public Use Fixtures
Hot
Cold
Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
1 Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50
3 Bathtub, lavatory and water closet - FT group 6.00 10.50 12.00
Total Water Supply Fixture Units
10.00
19.50
23.50
16.1 Gallon per minute demand of the building. Predominatly Flush Tank
20.8 Pressure available for uniform loss. For the table use - 21.0
Maximun Allowable load for Coppe@eType 1M,! ASTM B88
.r"'.
" I
I,
Nominal Size 1/2 5/8 3/4 1 1 1/4 11/2 2 21/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
MaXimum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
r\
~
.."
Fixture Listing
Date: December 18, 2001
r\i
Name: O'NEILL ENTERPRISE
Project: NSFR
Street:
Street: 2445 HICKORY LN
City:
City:
Non Public Use Fixtures
Hot
Cold
Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
I Kitchen Sink 1.00 1.00 1.50
1 Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50
3 Bathtub, lavatory and water closet - FT group 6.00 10.50 12.00
Total Water Supply Fixture Units
10.00
19.50
23.50
16.1 Gallon per minute demand of the building. PredominatIy Flush Tank
20.8 Pressure available for uniform loss. For the table use - 21.0
Maximun Allowable load for Crosslinked Polyethylenif(P~xffublng ASTM F876
f\
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .485 .584 .681 .875 1.069 1,263 1.653 0 0 0
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4 6.5 9 15 22 31 53 0 0 0
Maximum FM WSFU 0 0 0 5 7 15 58 0 0 0
Maximum FT WSFU 4 8 11.? 21.5 35 58 142 0 0 0
../
c?3,5
~
J1, ::
r~