HomeMy WebLinkAboutBuilding Z2-2042-0807
"'
ct)
.OJHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLo.shkosh.wi.us
Pi
ON THE WATER
August 10, 2007
Adam Heindel
Excel Engineering, Inc
100 Camelot Drive
Fond du Lac, WI 54935
Randy Schmiede1
Bros LLC
222 Ohio Street
Oshkosh, WI 54902
Site: Plan Number: Z2-2042-0807
Anytime Fitness
312 Koeller St
Oshkosh WI 54901
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: lIB - 4820 Sq Ft.; Unspril1kIered
Occupancy: A3: Assembly
other occupancies in same building - B: Business Office, M Mercantile / Retail - Separated Uses
MaxirnumNo of Occupants: 96
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
. 706.4 Continuity. Fire barriers shall extend from the top of the floor/ceiling assembly below to the
underside of the floor or roof slab or deck above and shall be securelv attached thereto. Section 4 on Sheet
A5.0 does not show the drywall being securely attached to the roof deck -verify that drywall is
supported at the roof deck. Verify that existing walls shown to be rated walls have been properly
constructed to meet rated wall requirements, as well as any penetrations being properlyfirestopped
. IRC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copiesofthefirestopping systems
are required to be provided at the time of inspection.
.Comm 61.30(3) This review does not include lighting. Carom 63.0001 Prior to installation, lighting
plans andca1culations shall be prepared in compliance with the code. The plans shall be available upon
request.
. Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment.
\\OSlIKOSHMISF:'r'.i)",!xJrtments\lnspectioTI:;\].'lanIk\'iew\Comnwrcj,ll Pian Review 2007\Z.2-2042-0807 .3 12 K<,elier Sl \.11<lg OniydtK .
Page 1 of2
..t
i
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department orits
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Corom 61.31(1).
SUBMIT:
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making themnecessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
this correspondence may be made to me at the number listed below or the address on this letterhead.
Bnan Noe
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property fIle
Fee Required $
Fee Received $
Balance Due $
390.00
390.00
0.00
\\031 fKOSlIIvHSFS\Dep;JTtments\fnspt'ttion:i\J'JanR,cvie\\"\CommeTci:;! Phm Review 200T7::-2042-0807 .3 [2 K...>dkr St 1hlg Oniyd,,,'
Page 2 of2