Job Address 1855 HICKORY LN
QITY OF OSHKOSH
-/ I
PLUMBING PERMIT - APPLICATION AND RECORD
Owner PAUL WAGNER
Contractor AHERN-GROSS INC.
Category 402 - Residential-Exterior (other)
Bathtub 2 Shower 0 Ejector/Gri nd Dip Well F Prep Sink
-
Whirlpool Floor Drain 1 Water Softner Drink Ftn Serv Sink
Lavatory 3 Lndry Tray Local Waste 1 Wait. St. Shamp Sink
-
Toilet 3 Lndry Stndp 1 Clothes Wshr 1 Ice Chest FlrlWst Sink
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin
-
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
-
Site Drain 1 Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use/Nature NSFRI
of Work
No 88748
Create Date 08/15/2001
Plan
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
Size
Type
Conn. Type
#
Material
Sanitary Sewer
Storm Sewer
Water Service
Valuation
$6,000.00
$0.00
Permit Fees
$114.00
Plan Approval
Issued By I~
D Permit Voided I
Date 08/27/2001
In the performance of 'i~rk, I agree~..wrform all work pursuant to rules governing the described construction.
SignatureJ?2r~t:[ !fc,~r )},1"r/!~ 6/'..1.]'; ~ j2~~3/cf;1f~ Date
Agent/Owner
~--cJ7-D/
Address 218 S MAIN ST
FOND DU LAC WI 54963 - 0000
Telephone Number 920-921-1414
~
WATER DISTRIBUTION DATASHEET
~
Date: October 26,2001
1"""'\.
J
Name: AHERN-GROS
Project: NSFR
Street:
Street: 1855 HICKORY LN
City:
City:
1. 14.9 Gallon per minute buiding demand, predominatly Flush Tank.
2. 54.0 Low pressure at the Main in the Street.
3. .0 Lb loss from a .0 ft difference in elevation from Main in the Street to the Water Meter.
4a. 1.3 Lb loss from a 15.0 ft I" Copper Tube Type K ASTM B88 water service from the Main in the Street to the curb stop.
- Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 6.1 ft per sec.
4b.~ Lb loss from a 85.0 ft I" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 6.1 ft per sec.
5. 3.3 Lb loss from a 3/4in Meter
6. 42.2 Lbs of pressure availabF-e at the Water Meter. This value is entered in (B) below.
.~
The (A) value listed below is determined by using the following formula, then rounding the tesult up.
A = B-(C+D+E) x 100
F
A. ~ Pressure available for uniform loss (psi/l00 feet of pipe).
~,
i
B. 42.2 Lbs of pressure available at the Water Meter.
C. 20.0 Pressure needed at the controlling fixture. SHWR FAUCET-MASTER BR
D. ~ Lb loss resulting from a 12..0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. 90.0 Ft Developed length from the 60.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual 1. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7 0 18 34 62 112 270 484 776 1835
o
)
Fixture Listing
"
Date: October 26,2001
r"\.
Name: AHERN-GROS
Project: NSFR
Street:
Street: 1855 HICKORY LN
City:
City:
Non Public Use Fixtures
Hot
Cold
Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
1 Lavatory .50 .50 1.00
1 Water Closet, gravity type flush tank .00 2.00 2.00
2 Bathtub, lavatory and water closet - FT group 4.00 7.00 8.00
.
Public Use Fixtures
Hot Cold Total
.00 I .50 I .50
Q Ice Maker ..
~,
Total Water Supply Fixture Units
7.50
18.00
21.50
/
14.9 Gallon per minute demand of the building. Predominatly Flush Tank
18.9 Pressure available for uniform loss. For the table use - 19.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7 0 18 34 62 112 270 484 776 1835
/"""'>....
./
'"
WA1:E~ CALCULATION WORKSHEET FOR
JffF~ "{~ ~
NAMe OF PROJeqT
INFOR~TIONREQUIRED TO CALCULATE WATER SERVICE SIZE
1. Demand of building in building in gallons per minute. WSFU's 25,0 = (GPM) fl.O
,E.
2.
3.
4.
5.
Difference in elevation from main or external pressure tank to building control valve. (feet)
Size of water meter (when meter is required) .5/S" -' 3/4"l{" 1" ...,-' 1-1/2" _' 2" _' larger size
Developed length from main or external pressure tank to building control valve. (feet)
low pressure at main in .street or external pressure tank. (psi)
CALCULATE WATER SERVICE PRESSURE LOSS
6.
7.
low pressure at main in street or external pressure tank. (value of # 5 above)
Determine pressure loss due to friction in ,I' inch diameter I
water service. ~
ry./ater service piping ~aterial i~ Dc-I .......:._.~ )
Determine pressure loss due to elevation,
(multiply the value of# 2 above by .434) G-'/'. f-.j .z,Li
Subtract value of "7"
subtotal
S.
Subtract -lalue of "S"
g.
Available pressure after the bldg. control valve. (enter in "B" below)
subtotal
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "An)
Go
*'
f5,:J
57
57
14/1
Ll? .to
Z.to
10
Value of "B" 'to
B.
C.
Available pressure after the bldg. control valve. (from Mg" above)
Pressure loss of water meter (when meter is required)
Subtract value of lie"
subtotal
D.
Pressure at controlling fixture.
(Controlling fixture is ~:E ~ . Y~L\IfC
I
Subtract value of "0"
subtotal
Difference in elevation between the building control valve
and the controlling fixture in feet 20 X' .434 psi/ft.
Subtract value of "E"
subtotal
F.
Pressure loss due to water treatment devices,instantaneous
water heaters and backflow prevente[S which serve the
controlling fixture.
(Pressu~ loss due to
subtotar
Subtract value of "F"
--
G.
Developed length frQm building control valve to controlling
~re in feet.GJO X1.5 .
Divide by value of MG"
subtotal
(Water distribution piping material is xYPE: P\ CG::R )
Multiply by
A
Pressure available for uniform loss
"A" = '
SeD.e47S (R1119ll)
A-
5.
3S
;2..0
is
8,4>
~.1
o
~,1
<00
,1/
100
/1
[1
"
J I'''} fR/1l. ~